INSTRUCTION MANUAL DAAB AUTOMATIC CONTROLL UNIT EP104 4.08
20
Instruction manual edition 1 for EP104 version 4.08
Quick guide for commissioning of swing gates
• Prerequisites
The electrical installation is complete and drive units should be disengaged from the drive arm. Operate only one drive unit at
a time and start with drive unit 1. The type of motor power in C202 is set to 0, 3x400V with neutral. Limit switches must be
of encoder type. View mode, C999 is set to 2. The indications for photocell, stop circuit and 24V lights green
• Comissioning of drive unit 1
Direction of movement:
Set L001 to 4, hold-to-run without limit switches. Check that the drive arm mounting is moving in
the right direction while pressing OPEN or CLOSE button on the control board. If the direction of movement is wrong, see
section "Connections" in the "Instruction Manual EP104".
Open and closed position:
Engage gate leaf of drive unit 1 and set the positions for open and closed. After this is done
L001 should be set to 1, Encoder.
L110=1, Drive unit 1 Left position
L120=2; Drive unit 2 Right position
L123, Closed position
L122, Open position
L121, Position readout
Motor protection:
Read out motor current in C251 under operation and apply appropriate values in C252 and C253.
Opening
/
Closing
C252
/
C253
150%
(50%)
Current(A)
Time
Opening
/
Closing
C252
/
C253
150%
(50%)
Current(A)
Time
C221
C221, Motor protection delay
C251, Read out current
E201
C251, Read out current
Opening
/
Closing
C252
/
C253
150%
(50%)
Current(A)
C221, Motor protection delay
Opening
/
Closing
C252
/
C253
150%
(50%)
Current(A)
C221
E206
Time
Time
C251, Read out current
C251, Read out current
Load guard:
Set C999 to 3. A swing gate application usually does not require personal protection, if so C230 is set to
0.00. Set C033 to 3, impulse, to activate the load guard. Make sure that the settings of the C232 and C233 is low enough to
prevent material damage, but at the same time that it is guaranteed to open due to weather, wind and mechanical changes.
Opening
/
Closing
C232
/
C233
Power(kW)
Time
Opening
/
Closing
C232
/
C233
Power(kW)
Time
C212, Load guard start delay
C211, Load guard delay
Reversing
C231, Power read out
-0,30kW
C212
C231, Power read out
Safety edges:
Check the safety edges on gate leaf 1 by pressing the safety edges during movement. Please note that the
safety function in opening direction is switched off in C131. If the safety edges are activated during closing movement the
gate should reverse to fully opened position, while in opening movement it should reverse to closed position during the time
in C494. A flashing indication at SE.C1 or SE.O1 means that the safety edge was activated but no longer is.