Table 13-5
Model(s):
CSAD UiAWP 200 PS
Air-to-water heat pump:
YES
Water-to-water heat pump:
NO
Brine-to-water heat pump:
NO
Low-temperature heat pump:
YES
Equipped with a supplementary heater:
NO
Heat pump combination heater:
NO
Declared climate condition:
AVERAGE
Parameters are declared for low-temperature application.
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Rated heat output (*)
Prated
31
KW
Seasonal space heating energy
efficiency
η
s
135
%
Declared capacity for heating for part load at outdoor temperature Tj
Declared coefficient of performance or primary energy ratio for part load at
outdoor temperature Tj
Tj = -7
℃
Pdh
26.1
KW
Tj = -7
℃
COPd
2.59
-
Tj = 2
℃
Pdh
16.7
KW
Tj = 2
℃
COPd
3.56
-
Tj = 7
℃
Pdh
11.8
KW
Tj = 7
℃
COPd
3.87
-
Tj = 12
℃
Pdh
11.2
KW
Tj = 12
℃
COPd
5.70
-
Tj=bivalent temperature
Pdh
31.0
KW
Tj=bivalent temperature
COPd
2.32
-
Tj = operating limit
Pdh
31.0
KW
Tj = operating limit
COPd
2.32
-
For air-to-water heat pumps: Tj = -15
℃
Pdh
-
KW
For air-to-water heat pumps: Tj =
-15
℃
COPd
-
-
Bivalent temperature
Tbiv
-10
℃
For air-to-water heat pumps:
Operation limit temperature
TOL
-10
℃
Cycling interval capacity forheating
Pcy ch
-
KW
Cycling interval efficiency
COPcy c
-
-
Degradation co-efficient (**)
Cdh
0.99
--
Heating water operating limit
temperature
WTOL
35
℃
Power consumption in modes other than active mode
Supplementary heater
Off mode
Pof f
0.075
kW
Rated heat output (**)
Psup
-
-
Standby mode
Psb
0.075
kW
Thermostat-off mode
Pto
0.600
kW
Type of energy input
-
Crankcase heater mode
Pck
0.075
kW
Other items
Capacity control
variable
For air-to-water heat pumps: Rated
air flow rate, outdoors
-
24000
㎥
/h
Sound power level, outdoors
LWA
86
dB
For water- or brine-to-water heat
pumps: Rated brine or water flow
rate, outdoor heatexchanger
-
-
㎥
/h
Annual energy consumption
QHE
18998
kWh
For heat pump combination heater:
Declared load profile
-
Water heating energy
efficiency
η
wh
-
%
Daily electricity consumption
Qelec
-
kWh
Daily fuel consumption
Qf uel
-
kWh
Annual electricity consumption
AEC
-
kWh
Annual fuel consumption
AFC
-
GJ
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh,
and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh =0.99.
Information requirements for heat pump space heaters and heat pump combination heaters
52
Installation Manual___________________________________________________________________________________