8.5 Electric wiring
8.5.1 Electric wiring
1. The air-conditioner should apply special power supply, whose
voltage should conform to rated voltage.
2. Wiring construction must be conducted by the professional
technicians according to the labeling on the circuit diagram.
3. The power wire and the grounding wire must be connected
the suitable terminals.
4. The power wire and the grounding wire must be fasten up by
suitable tools.
5. The terminals connected the power wire and the grounding
wire must be fully fastened and regularly checked, in case to
become flexible.
6. Only use the electric components specified by our company,
and require installation and technical services from the
manufacturer or authorized dealer. If wiring connection fails to
conform to electric installation norm, failure of the controller,
electronic shock, and so on may be caused.
7. The connected fixed wires must be equipped with full
switching-off devices with at least 3mm contact separation.
8. Set leakage protective devices according to the requirements
of national technical standard about electric equipment.
9. After completing all wiring construction, conduct careful check
before connecting the power supply.
10. Please carefully read the labels on the electric cabinet.
11. The user’s attempt to repair the controller is prohibited, since
improper repair may cause electric shock, damages to the
controller, and so on. If the user has any requirement of repair,
please contact the maintenance center.
12.The power cord type designation is H07RN-F.
CAUTION
DSP1
DSP2
4
S5
ENC1
0-F
0-F valid for uint address
setting on the DIP switches
0 indicates the master unit and
1-F the auxiliary uints
(parallel connection) (0 by default)
ENC2
0-5
DIP switch for capacity selection
(
CSAD UiAWP 100 PS
defaults 2)
(
CSAD UiAWP 200 PS
defaults 5)
S5-1
4
OFF
Normal cooling mode
Valid for S5-1 OFF(factory default)
ON Low-temperature cooling mode
Valid for S5-1 ON
4
S5-3
OFF
Single water pump control
Valid for S5-3 OFF(factory default)
ON Multiple water pumps control
Valid for S5-3 ON
4
S5-4
OFF Normal control
Valid for S5-4 OFF(factory default)
ON
Remote control
valid for S5-4 ON
S5
ENC2
POWER
ENC4
NET_ADDRESS
S12
DSP1
DSP2
8.5.2
CSAD UiAWP 100 PS
and
CSAD UiAWP 200 PS
DIP switch, buttons and digital display positions of uints.
8.5.3
CSAD UiAWP 300 PS
DIP switch, buttons and digital display positions of uints.
Fig. 8-12 Display positions
Fig. 8-13 Display positions
8.5.4 DIP switch instructions
The definitions for DIP switch of
CSAD UiAWP 100 PS
and
CSAD UiAWP 200 PS
are different from those of
CSAD UiAWP 300 PS
.
See Table 8-6 for DIP switch instructions of
CSAD UiAWP 100 PS
and
CSAD UiAWP 200 PS
, and Table 8-7 for
CSAD UiAWP 300 PS
.
Table 8-6
CSAD UiAWP 100 PS
and
CSAD UiAWP 200 PS
21
Installation Manual___________________________________________________________________________________
Содержание CSAD UiAWP 100 PS Series