2.2  Installation and Setup of your Rad-DX 

2.2.1  Physical Installation 

The  Rad-DX  is  designed  to  be  either  wired  and  mounted  into  an  electrical  junction  box  or 
attached to a wall in close proximity to an outlet. 

2.2.1.1  Junction Box Method 

Mounting a Rad-DX unit directly into a junction box requires the following steps:  

Note:

 An electrician should complete the installation to ensure the quality of the installation and 

safety of the installer. 

1.

 

Mount the Rad-DX wall bracket onto the junction box using the screws included. If a non-
standard junction box is being used, connect the wall bracket to the wall with drywall 
anchors or wood screws.  

2.

 

Connect the black wire from the “pigtail” wire harness to the black wire in the junction box. 
Connect the white wire from the wire harness to the white wire in the junction box. 

3.

 

Plug the wire harness into the back of the Rad-DX unit. 

4.

 

Press the Rad-DX onto the wall bracket and make sure it is secure. It will snap into place. 
The Rad-DX can be removed from the bracket by lifting the top tab with a flathead 
screwdriver. 

 

 

Figure 2: Junction Box Mounting Method 

Содержание rad-DX

Страница 1: ...AND OPERATING INSTRUCTIONS FOR THE RADIATION DETECTION SYSTEM Including Version 14 January 2017 D tect Systems Group Visionary Products Inc 11814 South Election Road Suite 200 Draper UT 84020 www dtec...

Страница 2: ...9 3 1 1 DX View Software 9 3 1 2 DX Dashboard Software 9 3 1 3 DX Assistant Network Server 9 3 2 Using the LCD Screen 10 3 2 1 Explanation of Networking Icons on the LCD Touch Screen 11 4 Turning Off...

Страница 3: ...rt of a larger Rad DX network for monitoring areas such as buildings or other facilities 2 Installation and Configuration 2 1 System Components There are several configurations available for Rad DX sy...

Страница 4: ...1_14_Rad DX_Manual docx Page 4 of 19 Mounting Bracket USB Cable Wire Nuts and Mounting Screws Pigtail Wire Harness Power Cable black or white depending on color of Rad DX Table 1 Additional Rad DX Har...

Страница 5: ...the installer 1 Mount the Rad DX wall bracket onto the junction box using the screws included If a non standard junction box is being used connect the wall bracket to the wall with drywall anchors or...

Страница 6: ...Mount the Rad DX wall bracket to the wall using drywall anchors or wood screws 2 Connect the A C power cord to the Rad DX Then plug this cord into a nearby outlet Note The plug in wall method is meant...

Страница 7: ...losure also offers additional features to improve performance including two larger higher gain antennas a cooling fan and a larger longer lasting backup battery The option to include the NEMA enclosur...

Страница 8: ...ure for the detector Larger High Gain Antennas The standard Rad DX has two built in antennas one for Wi Fi and the other for Mesh communication The NEMA enclosure option comes with two larger higher g...

Страница 9: ...s a web server application which can be used to monitor and control a Rad DX network remotely It runs on either the D tect Cloud Server or on the DX Network Assistant if installed at your facility Usi...

Страница 10: ...Screen will appear on the LCD screen after the booting sequence is complete 4 The red lines shown below indicate the touch zone areas for each screen Reset the dose to zero by touching Total radiation...

Страница 11: ...rking Icons on the LCD Touch Screen The appearance of any network connection icon indicates that the device is currently connected via the referenced connection Wi Fi Connection Battery Level USB Conn...

Страница 12: ...ice will turn off If the power cable is still connected then the device will power cycle and turn back on The third method is to press and hold the battery icon located in the upper left hand corner o...

Страница 13: ...x 272 Touch Screen Units Rem hr Sv hr CPS Audible Alarm Piezoelectric buzzer with LCD Display version only Alarm Volume 98dB Humidity 95 non condensing Dimensions 5 97 x 5 92 x 1 75 15 2 cm x 15 cm x...

Страница 14: ...DX Dashboard software 6 1 2 Gateway to PC using DX View The DX Link can be used as a gateway while using the DX View to monitor one or several Rad DX detectors If the DX Link is inserted into a USB p...

Страница 15: ...n if the DX Link and the computer are not communicating Figure 10 Sample USB Power Adapter Figure 11 DX Link as a Repeater You can now extend the range of communication between the Rad DX and the moni...

Страница 16: ...partie responsible de la conformit ont pu vider I autorit de I utilisateur pour actioner cet equipment This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la class...

Страница 17: ...20cm between the radiator and your body Note Importante Pour l utilisation de dispositifs mobiles Declaration d exposition aus radiations Cet quipement est conforme aux limites d exposition aux rayon...

Страница 18: ...approved by the customer that are not included in either the Limited or Extended Warranty these services will be billed to the customer at D tect Systems standard prices and terms D tect Systems does...

Страница 19: ...become or in D tect System s opinion be likely to become the subject of a claim of infringement of a United States patent that you will permit D tect Systems at its option and expense either to procu...

Отзывы: