background image

Tech Support 

 

 

 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

Technical Support

 

You can find software updates and user documentation on the D-

Link website. 

 

D-Link provides free technical support for customers within the 

United States and within Canada for the duration of the service 

period, and warranty confirmation service, during the warranty 

period on this product. U.S. and Canadian customers can contact 

D-Link technical support through our website, or by phone. 

 

 

Tech Support for customers within the United States:

 

D-Link Technical Support over the Telephone: 

USA - 877-DLINK-55 (877-354-6555) 

D-Link Technical Support over the Internet: 

http://support.dlink.com 

Tech Support for customers within Canada: 

D-Link Technical Support over the Telephone: 

877-354-6560 

D-Link Technical Support over the Internet: 

http://support.dlink.com 

 

 

Содержание xStack DGS-3600 Series

Страница 1: ...xStack DGS 3600 Series Layer 3 Managed Gigabit Ethernet Switch i ...

Страница 2: ... permission of D Link Corporation is strictly forbidden Trademarks used in this text D Link and the D LINK logo are trademarks of D Link Corporation Microsoft and Windows are registered trademarks of Microsoft Corporation Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products D Link Corporation disclaims any prop...

Страница 3: ... this product may cause radio interference in which case the user may be required to take adequate measures Warnung Dies ist ein Produkt der Klasse A Im Wohnbereich kann dieses Produkt Funkstoerungen verursachen In diesem Fall kann vom Benutzer verlangt werden angemessene Massnahmen zu ergreifen Precaución Este es un producto de Clase A En un entorno doméstico puede causar interferencias de radio ...

Страница 4: ...n Guidelines 11 Installing the Switch without the Rack 12 Installing the Switch in a Rack 12 Mounting the Switch in a Standard 19 Rack 13 Power On 13 Power Failure 13 Installing the SFP Ports 14 Optional 10GE Uplink Module 14 External Redundant Power System 16 Connect to RPS 17 DPS 200 18 DPS 900 18 DPS 800 19 Connecting the Switch 20 Switch to End Node 20 Switch to Hub or Switch 21 Connecting to ...

Страница 5: ...uration 28 Introduction 28 Logging in to the Web Manager 28 Web based User Interface 29 Areas of the User Interface 29 Web Pages 29 Appendix A Technical Specifications 31 Appendix B Cables and Connectors 34 Appendix C Cable Lengths 35 Glossary 36 Warranty Support 47 ...

Страница 6: ...mands For example use the copy command Boldface Typewriter Font Indicates commands and responses to prompts that must be typed exactly as printed in the manual Initial capital letter Indicates a window name Names of keys on the keyboard have initial capitals For example Click Enter Italics Indicates a window name or a field Also can indicate a variables or parameter that is replaced with an approp...

Страница 7: ...the openings of the system Doing so can cause fire or electric shock by shorting out interior components Use the product only with approved equipment Allow the product to cool before removing covers or touching internal components Operate the product only from the type of external power source indicated on the electrical ratings label If unsure of the type of power source required consult your ser...

Страница 8: ...pecific caution statements and procedures Systems are considered to be components in a rack Thus component refers to any system as well as to various peripherals or supporting hardware CAUTION Installing systems in a rack without the front and side stabilizers installed could cause the rack to tip over potentially resulting in bodily injury under certain circumstances Therefore always install the ...

Страница 9: ...e the battery to explode Replace this battery only with the same or equivalent type recommended by the manufacturer Discard used batteries according to the manufacturer instructions Protecting Against Electrostatic Discharge Static electricity can harm delicate components inside the system To prevent static damage discharge static electricity from your body before touching any of the electronic co...

Страница 10: ...ddition the Switch has four 1000Mbps SFP combo ports located on the front panel These gigabit combo ports are ideal for connecting to a server or network backbone The DGS 3627G contains twenty four 1000Mbps SFP Small Form Factor Portable ports in addition to four 1000BASE T located on the front panel The DGS 3612 contains twelve 10 100 1000BASE T ports all of which are Auto MDI X MDI II convertibl...

Страница 11: ...mic VLAN groups Configurable VLAN ID 1 to 4094 Double VLAN Q in Q translation VLAN ASIC 768 entries Guest VLAN IGMP Snooping Multicast VLAN ISM VLAN including tag untagged member and source support and configurable multicast VLAN priority there is no limit on the total multicast address number per ISM VLAN entry MAC based VLAN ASIC 1024 VLAN MAC entries VLAN PVID auto assign VLAN trunking Subnet V...

Страница 12: ... Binding IMPB DHCPv6 security IP MAC Port Binding IMPB ND Snooping based security IP Directed Broadcast Loopback interface IGMP Source network check enable disable Multicast Route Management IPMC L2 Forward Border Gateway Protocol BGP Open Shortest Path First OSPF v2 v3 Open Shortest Path First OSPF Passive Interface Open Shortest Path First Not So Stubby Area OSPF NSSA IP interfaces 256 IP interf...

Страница 13: ...ce CLI Passed Metro Ethernet Forum MEF 9 and 14 MIBs for o RFC1213 MIB II o RFC1493 Bridge MIB o RFC 1907 SNMPv2 MIB o RFC 1757 and RFC 2819 RMON o RFC 2021 RMONv2 o RFC 1643 RFC 2358 and RFC 2665 Ether like MIB o RFC 2668 802 3 MAU MIB o RFC 2674 for 802 1p MIB o RFC 2233 and RFC 2863 Interface MIB o RFC 2618 RADIUS Authentication Client MIB o IGMPv3 MIB o RFC 1724 RIPv2 MIB o RFC 1850 OSPFv2 MIB...

Страница 14: ...liant IEEE 802 3u compliant IEEE 802 3x flow control support in full duplex One connector in the rear to add an external Redundant Power Supply DPS 500 Auto MDI X MDI II cross over support DGS 3612 uses a DPS 200 Redundant Power Supply Supports the following SFP transceivers DEM 310GT 1000BASE LX DEM 311GT 1000BASE SX DEM 312GT2 1000BASE LX DEM 314GT 1000BASE LHX DEM 315GT 1000BASE ZX DEM 330T R W...

Страница 15: ...le port LEDs for Power Console RPS and Link Act Speed for each port Figure 1 2 Front Panel of the DGS 3612G DGS 3627 Twenty four 10 100 1000BASE T ports Four Combo SFP ports located to the right One female DCE RS 232 DB 9 console port LEDs for Power Console RPS Link Act Speed and 10GE for each port Stacking Module Numbered LED Figure 1 3 Front Panel of the DGS 3627 DGS 3627G Twenty four SFP 1000Mb...

Страница 16: ... Switch in the switch stack This field will read 1 for a switch in standalone mode When the switch in question is a master of a switch stack the number of the switch in the stack will be displayed and the letter H will flash alternatively with this number Port LEDs 10 100 1000Mbps ports Green Solid Denotes an active connection at 1000Mbps Blinking Denotes data transfer at 1000Mbps Orange Solid Den...

Страница 17: ...xStack DGS 3600 Series Layer 3 Managed Gigabit Ethernet Switch 8 Figure 1 6 DGS 3612G LEDs Figure 1 7 DGS 3627 LEDs Figure 1 8 DGS 3627G LEDs Figure 1 9 DGS 3650 LEDs Figure 1 10 DGS 3612 LEDs ...

Страница 18: ...s Figure 1 13 Rear panel view of the DGS 3627 and DGS 3627G DGS 3650 The rear panel of DGS 3650 contains an AC power connector an outlet for an optional external RPS a DCE RS 232 console port and two slots for additional 10GE optional modules Figure 1 14 Rear Panel view of DGS 3650 The rear panel includes an outlet for an optional external redundant power supply When power fails the optional exter...

Страница 19: ... Do not block these openings on either side of the Switch Leave at least 6 inches of space at the rear and sides of the Switch for proper ventilation Be reminded that without proper heat dissipation and air circulation system components might overheat which could lead to system failure Figure 1 15 Side Panel of the DGS 3612 Figure 1 16 Side Panel of the DGS 3612G Figure 1 17 Side Panel of the DGS ...

Страница 20: ...idelines for setting up the Switch Install the Switch on a sturdy level surface that can support at least 4 24kg 9 35lbs of weight for the DGS 3612 DGS 3612G DGS 3627 DGS 3627G or 6 02kg 13 27lbs for DGS 3650 Do not place heavy objects on the Switch The power outlet should be within 1 82 meters 6 feet of the Switch Visually inspect the power cord and see that it is fully secured to the AC DC power...

Страница 21: ...low enough ventilation space between the Switch and any other objects in the vicinity Figure 2 1 Prepare Switch for installation on a desktop or shelf Installing the Switch in a Rack The Switch can be mounted in a standard 19 rack Use the following diagrams to guide you Figure 2 2 Fasten mounting brackets to Switch Fasten the mounting brackets to the Switch using the screws provided With the brack...

Страница 22: ...ne component out of the rack on its slide assemblies at one time The weight of more than one extended component could cause the rack to tip over and may result in injury Figure 2 3 Installing Switch in a rack Power On Plug one end of the AC power cord into the power connector of the Switch and the other end into the local power source outlet After the Switch is powered on the LED indicators will m...

Страница 23: ...llow the administrator to add a single port 10GE stacking module which will transmit information at a rate of ten gigabits a second This port is compliant with standard IEEE 802 3ae supports full duplex transmissions only and is to be used with XFP MSA compliant transceivers The DEM 410CX will transfer information at a rate of ten gigabits a second but is used as an uplink module to a network devi...

Страница 24: ...e it in to the available slot at the rear of the Switch until it reaches the back as shown in the following figure At the back of the slot are two sets of plugs that must be connected to the module Gently but firmly push in on the module to secure it to the Switch The module should fit snugly into the corresponding receptors Figure 2 8 Inserting the optional modules into the Switch Now tighten the...

Страница 25: ...900 or DPS 800 Figure 2 10 Installing the DPS 500 CAUTION Installing systems in a rack without the front and side stabilizers installed could cause the rack to tip over potentially resulting in bodily injury under certain circumstances Therefore always install the stabilizers before installing components in the rack After installing components in a rack do not pull more than one component out of t...

Страница 26: ...n the switch and the other end into the redundant power supply 2 Using a standard AC power cable connect the redundant power supply to the main AC power source A green LED on the front of the DPS 500 will glow to indicate a successful connection 3 Re connect the switch to the AC power source A LED indicator will show that a redundant power supply is now in operation 4 No change in switch configura...

Страница 27: ...talling the DPS 200 into the DPS 900 The RPS can be mounted in a standard 19 rack Use the following diagram to guide you Figure 2 13 Installing the DPS 900 into the equipment rack CAUTION Installing systems in a rack without the front and side stabilizers installed could cause the rack to tip over potentially resulting in bodily injury under certain circumstances Therefore always install the stabi...

Страница 28: ...is a standard size rack mount 1 standard unit in height designed to hold up to two DPS 200 redundant power supplies Figure 2 14 Install DPS 200 in DPS 800 The RPS can be mounted in a standard 19 rack Use the following diagram to guide you Figure 2 15 Install DPS 800 in an Equipment Rack ...

Страница 29: ... End Node End nodes include PCs outfitted with a 10 100 or 1000 Mbps RJ 45 Ethernet Fast Ethernet Network Interface Card NIC and most routers An end node can be connected to the Switch via a twisted pair Category 3 4 or 5 UTP STP cable The end node should be connected to any of the ports of the Switch Figure 3 1 Switch connected to an end node The Link Act LEDs for each UTP port will light green o...

Страница 30: ... fiber optic cabling Figure 3 2 Switch connected to a normal non Uplink port on a hub or switch using a straight or crossover cable NOTICE When the SFP transceiver acquires a link the associated integrated 10 100 1000BASE T port is disabled Connecting to Network Backbone or Server The two Mini GBIC combo ports are ideal for linking to a network backbone or server The copper ports operate at a spee...

Страница 31: ... Command Line Console Interface through the Serial Port The user can also connect a computer or terminal to the serial console port to access the Switch The command line driven interface provides complete access to all Switch management features Connecting the Console Port RS 232 DCE The Switch provides an RS 232 serial port that enables a connection to a computer or terminal for monitoring and co...

Страница 32: ...or program 14 Make sure the terminal or PC you are using to make this connection is configured to match these settings If you are having problems making this connection on a PC make sure the emulation is set to VT 100 You will be able to set the emulation by clicking on the File menu in you HyperTerminal window clicking on Properties in the drop down menu and then clicking the Settings tab This is...

Страница 33: ...l R to refresh the screen This command can be used at any time to force the console program in the Switch to refresh the console screen Press Enter in both the Username and Password fields You will be given access to the command prompt DGS 3627G 5 shown below There is no initial username or password Leave the Username and Password fields blank DGS 3627 Gigabit Ethernet Switch Command Line Interfac...

Страница 34: ...rator account being created and press the Enter key 3 Again the user will be prompted to enter the same password again to verify it Type the same password and press the Enter key 4 Successful creation of the new administrator account will be verified by a Success message NOTE Passwords are case sensitive User names and passwords can be up to 15 characters in length The sample below illustrates a s...

Страница 35: ...sted and configured with a shared set of privileges The SNMP version may also be set for a listed group of SNMP managers Thus you may create a group of SNMP managers that are allowed to view read only information or receive traps using SNMP v 1 while assigning a higher level of security to another group granting read write privi leges using SNMP v 3 Using SNMP v 3 individual users or groups of SNM...

Страница 36: ...The IP address may be set using the Command Line Interface CLI over the console serial port as follows Starting at the command line prompt enter the commands config ipif System ipaddress xxx xxx xxx xxx yyy yyy yyy yyy Where the x s represent the IP address to be assigned to the IP interface named System and the y s represent the corresponding subnet mask Alternatively you can enter config ipif Sy...

Страница 37: ...access the same internal switching software and configure it Thus all settings encountered in web based management are the same as those found in the console program Logging in to the Web Manager To begin managing the Switch simply run the browser installed on your computer and point it to the IP address you have defined for the device The URL in the address bar should read something like http 123...

Страница 38: ...e here Area 3 Presents switch information based on user selection and the entry of configuration data Web Pages When connecting to the management mode of the Switch with a Web browser a login screen is displayed Initially there is no user name or password to access the Switch s management mode Click the OK button to proceed Below is a list of the main folders available in the Web interface Adminis...

Страница 39: ...Protection Settings ARP Spoofing Prevention Settings Access Authentication Control MAC based Access Control Safeguard Engine Traffic Segmentation SSL SSH Common Authentication and Japanese Web based Access Control JWAC Monitoring Contains the following folders and windows Device Status Module Information DRAM Flash Utilization CPU Utilization Port Utilization Packets Errors Packet Size Browse Rout...

Страница 40: ... duplex Flow Control IEEE 802 1u Fast Ethernet Standards CSMA CD Data Transfer Rates Ethernet Fast Ethernet Gigabit Ethernet Fiber Optic XFP Support CX4 Support Half duplex Full duplex 10 Mbps 20Mbps 100Mbps 200Mbps N A 2000Mbps SFP Mini GBIC Support IEEE 802 3u 100BASE FX DEM 210 transceiver IEEE 802 3u 100BASE FX DEM 211 transceiver IEEE 802 3z 1000BASE LX DEM 310GT transceiver IEEE 802 3z 1000B...

Страница 41: ...odules Physical and Environmental Internal Power Supply Redundant Power Supply AC Input 100 240 VAC 50 60 Hz Output 12V 10A Max Power Consumption DGS 3612 45W DGS 3612G 50W DGS 3627 95W DGS 3627G 77W DGS 3650 137W DC Fans DGS 3612 Two 40mm x 40mm x 20mm fans DGS 3612G Three 40mm x 40mm x 20mm one 50mm x 50mm x 20mm fans DGS 3627 Four 40mm x 40mm x 20mm one 50mm x 50mm x 20mm one 44mm x 44mm x 11mm...

Страница 42: ...mission Method Store and forward Packet Buffer 2 MB per device Packet Filtering Forwarding Rate 14 881 pps 10M port 148 810 pps 100M port 1 488 100 pps 1Gbps port MAC Address Learning Automatic update Supports 16K MAC address Priority Queues 8 Priority Queues per port Forwarding Table Age Time Max age 10 1000000 seconds Default 300 ...

Страница 43: ...nt The following diagrams and tables show the standard RJ 45 receptacle connector and their pin assignments Figure B 1 The standard RJ 45 port and connector RJ 45 Pin Assignments Contact MDI X Port MDI II Port 1 RD receive TD transmit 2 RD receive TD transmit 3 TD transmit RD receive 4 1000BASE T 1000BASE T 5 1000BASE T 1000BASE T 6 TD transmit RD receive 7 1000BASE T 1000BASE T 8 1000BASE T 1000B...

Страница 44: ... Media Type Maximum Distance Mini GBIC 1000BASE LX Single mode fiber module 1000BASE SX Multi mode fiber module 1000BASE LHX Single mode fiber module 1000BASE ZX Single mode fiber module 10km 550m 2km 40km 80km 1000BASE T Category 5e UTP Cable Category 5 UTP Cable 1000 Mbps 100m 100BASE TX Category 5 UTP Cable 100 Mbps 100m 10BASE T Category 3 UTP Cable 10 Mbps 100m ...

Страница 45: ...higher level protocols are involved Bridges form a single logical network centralizing network administration broadcast A message sent to all destination devices on the network broadcast storm Multiple simultaneous broadcasts that typically absorb available network bandwidth and can cause network failure console port The port on the Switch accepting a terminal or modem connector It changes the par...

Страница 46: ...l Line Internet Protocol A protocol which allows IP to run over a serial line connection SNMP Simple Network Management Protocol A protocol originally designed to be used in managing TCP IP internets SNMP is presently implemented on a wide range of computers and networking equipment and may be used to manage many aspects of network and end station operation Spanning Tree Protocol STP A bridge base...

Страница 47: ...iquidators expressly disclaim their warranty obligation pertaining to the product and in that case the product is being sold As Is without any warranty whatsoever including without limitation the Limited Warranty as described herein notwithstanding anything stated herein to the contrary Submitting A Claim The customer shall return the product to the original purchase point based on its return poli...

Страница 48: ...opyright Statement No part of this publication or documentation accompanying this product may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from D Link Corporation D Link Systems Inc as stipulated by the United States Copyright Act of 1976 and any amendments thereto Contents are subject to change without...

Страница 49: ...Registration Register your D Link product online at http support dlink com register Product registration is entirely voluntary and failure to complete or return this form will not diminish your warranty rights ...

Страница 50: ...e warranty period on this product U S and Canadian customers can contact D Link technical support through our website or by phone Tech Support for customers within the United States D Link Technical Support over the Telephone USA 877 DLINK 55 877 354 6555 D Link Technical Support over the Internet http support dlink com Tech Support for customers within Canada D Link Technical Support over the Tel...

Страница 51: ...00pm Sat 10 00am 02 00pm 0 05ppm peak 0 045ppm off peak Times Internet http dlink com Technische Unterstützung Deutschland Web http dlink com Telefon 49 0 1805 2787 0 14 pro Minute Zeiten Mo Fr 09 00 17 30 Uhr Österreich Web http dlink com Telefon 43 0 820 480084 0 116 pro Minute Zeiten Mo Fr 09 00 17 30 Uhr Schweiz Web http dlink com Telefon 41 0 848 331100 0 08 CHF pro Minute Zeiten Mo Fr 09 00 ...

Страница 52: ...15per minuut Tech Support for customers within Belgium http dlink com 028801640 0 175per minuut spitsuren 0 0875per minuut daluren Technische ondereuning voor klanten in Luxemburg http dlink com 32 70 66 06 40 Asistencia Técnica Asistencia Técnica Telefónica de D Link 34 902 30 45 45 0 067 min De Lunes a Viernes de 9 00 a 19 00 http dlink com Supporto tecnico Supporto Tecnico dal lunedì al venerdì...

Страница 53: ... 17 00 Volání je zpoplatněno dle příslušných tarifů Vašeho operátora Technikai Támogatás Tel 06 1 461 3001 Fax 06 1 461 3004 Land Line 14 99 HUG min Mobile 49 99 HUF min email support dlink hu URL http dlink com Teknisk Support D Link Teknisk Support over Internett http dlink com D Link Teknisk telefonsupport 815 69 755 Hverdager 08 00 17 00 Teknisk Support D Link teknisk support over telefonen Tl...

Страница 54: ...pport Center http dlink com Καλύμνου 12 112 51 Αθήνα Τηλ 213 0020353 Δευτέρα Παρασκευή 09 00 19 00 Fax 210 8653172 Assistência Técnica Assistência Técnica da D Link na Internet http dlink com e mail soporte dlink es Teknisk Support D Link Teknisk Support via Internet http dlink com D Link Teknisk Support via telefon 0770 33 00 35 Vardagar 08 00 17 00 ...

Страница 55: ...ink com Tehnična podpora Zahvaljujemo se vam ker ste izbrali D Link proizvod Za vse nadaljnje informacije podporo ter navodila za uporabo prosimo obiščite D Link ovo spletno stran www dlink eu http dlink com Suport tehnic Vă mulţumim pentru alegerea produselor D Link Pentru mai multe informaţii suport şi manuale ale produselor vă rugăm să vizitaţi site ul D Link www dlink eu http dlink com ...

Страница 56: ...day 9 30AM to 6 30PM Thursdays 9 30AM to 2 00 PM E mail Support sa dlink me com D Link Middle East Dubai U A E Plot No S31102 Jebel Ali Free Zone South P O Box 18224 Dubai U A E Tel 971 4 8809022 Fax 971 4 8809066 8809069 Technical Support 971 4 8809033 General Inquiries info me dlink me com Tech Support support me dlink me com Egypt 1 Makram Ebeid Street City Lights Building Nasrcity Cairo Egypt ...

Страница 57: ...one 212 663 72 73 24 Email support na dlink me com Lebanon RMA center Dbayeh Lebanon PO Box 901589 Tel 961 4 54 49 71 Ext 14 Fax 961 4 54 49 71 Ext 12 Email taoun dlink me com Bahrain Technical Support 973 1 3332904 Kuwait Technical Support 965 22453939 965 22453949 Türkiye Merkez İrtibat Ofisi Ayazağa Maslak yolu Erdebil Cevahir İş Merkezi No 5 A Ayazağa Maslak İstanbul Tel 90 212 2895659 Ücretsi...

Страница 58: ...0 г Киев ул Межигорская 87 А офис 18 Тел 38 044 545 64 40 E mail kiev dlink ru Беларусь 220114 г Минск проспект Независимости 169 БЦ XXI Век Тел 375 17 218 13 65 E mail minsk dlink ru Казахстан 050008 г Алматы ул Курмангазы 143 уг Муканова Tел факс 7 727 378 55 90 E mail almaty dlink ru Армения 0038 г Ереван ул Абеляна 6 1 4 этаж Тел Факс 374 10 398 667 E mail erevan dlink ru Грузия Тел Факс 995 5...

Страница 59: ...s siguientes teléfonos de D Link PAIS NUMERO Argentina 0800 12235465 Chile 800 260200 Colombia 01800 510070 Costa Rica 0800 0521478 Ecuador 1800 035465 El Salvador 800 6335 Guatemala 1800 8350255 México 01800 0626270 Panamá 011 008000525465 Perú 0800 00968 Venezuela 0800 1005767 Soporte Técnico de D Link a través de Internet Horario de atención Soporte Técnico en www dlinkla com e mail soporte dli...

Страница 60: ...Suporte Técnico Caso tenha dúvidas na instalação do produto entre em contato com o Suporte Técnico D Link Acesse o site www dlink com br suporte ...

Страница 61: ...區技術支援工程師聯絡 D Link 免付費技術諮詢專線 0800 002 615 手機付費電話 02 6600 0123 8715 服務時間 週一至週五 早上9 00到晚上9 00 不含周六 日及國定假日 網 站 http www dlink com tw 電子郵件 dssqa_service dlink com tw 如果您是台灣地區以外的用戶 請參考D Link網站全球各地 分公司的聯絡資訊以取得相關支援服務 產品保固期限 台灣區維修據點查詢 請參考以下網頁說明 http www dlink com tw 產品維修 使用者可直接送至全省聯強直營維修站或請洽您的原購買經銷商 ...

Страница 62: ...okumentasi pengguna dapat diperoleh pada situs web D Link Dukungan Teknis untuk pelanggan Dukungan Teknis D Link melalui telepon Tel 62 21 5731610 Dukungan Teknis D Link melalui Internet Email support dlink co id Website http support dlink co id ...

Страница 63: ...Technical Support この度は弊社製品をお買い上げいただき 誠にありがとうご ざいます 下記弊社 Web サイトからユーザ登録及び新製品登録を 行っていただき ダウンロードサービスにて サポート情報 ファームウェア ユーザマニュアルを ダウンロードすることができます ディーリンクジャパン Web サイト URL http www dlink jp com ...

Страница 64: ...技术支持 办公地址 北京市东城区北三环东路 36 号 环球贸易中心 B 座 26F 02 05 室 邮编 100013 技术支持中心电话 400 629 6688 技术支持中心传真 028 87300889 各地维修中心地址请登陆官方网站查询 网址 http www dlink com cn 400电话工作时间 工作日9 00 19 00 节假日9 00 18 00 ...

Страница 65: ... site 1 employee 2 9 10 49 50 99 100 499 500 999 1000 or more 3 What network protocol s does your organization use XNS IPX TCP IP DECnet Others_____________________________ 4 What network operating system s does your organization use D Link LANsmart Novell NetWare NetWare Lite SCO Unix Xenix PC NFS 3Com 3 Open Cisco Network Banyan Vines DECnet Pathwork Windows NT Windows 98 Windows 2000 ME Windows...

Страница 66: ......

Отзывы: