Module Type
RG-PA1200
RG-PA1200E
RG-PA1200I
Rated
Voltage
Range
100-240VAC, 50/60Hz
100-240VAC, 50/60Hz
100-120VAC, 200-240VAC, 50/60Hz
Maximum
Voltage Range
90-264VAC, 47/-63Hz
90-264VAC, 47-63Hz
90-264VAC, 47-63Hz
Maximum
Output Power
1200W
1200W
90-176VAC power: 530W
176-264VAC power: 1400W
Power Cable
10A
16A
16A
Module Type
RG-PA2000I
RG-PA2000
RG-PA800IF
Rated
Voltage
Range
100-120VAC, 200-240VAC, 50/60Hz
100-240VAC, 50/60Hz
100-240VAC, 50-60Hz
Maximum
Voltage Range
90-264VAC, 47-63Hz
90-264VAC, 47-63Hz
90-264VAC, 47-63Hz
Maximum
Output Power
90-176VAC power: 1080W
176-264VAC power: 2000W
90-176VAC power: 1200W
176-264VAC
power:
2000W
90-176VAC power: 400W
176-264VAC
power:
800W
Power Cable
16A
16A
10A
The RG-S8614/S8610/S8606/S8606 B system supports 1+1 redundancy for the power supply. For higher stability
and reliability of the entire system, you are recommended to configure 1+1 power module redundancy for the
RG-S8614/S8610/S8606/S8606 B.
In dual power mode, shut down the power switch if PA1200/PA1200E/PD1200/PD2000 and PA2000
V1.00/V1.01/V1.02 coexist. No matter if the power cord is removed or not, the system prompts
“LinkAndNoPower”
when you are viewing the power status.
In dual power mode, shut down the power switch if RG-PA1200I, RG-PA2000I, RG-PA2000 V1.10 and later version
coexist. If the power cord is connected, the system prompts
“LinkAndPower” when you are viewing the power status;
if the power cord is removed, the system prompts
“LinkAndNoPower” when you are viewing the power status. It is
recommended remove the power cord when you are shutting down the power.
RG-PD1200/PD2000
The DC power module RG-PD1200/PD2000 provides 48 V DC power input interface for RG-S8614/S8610/S8606.
LED
Sign
Status
Details
IN
Off
No power input.
Solid green
Power input is operational.
OUT
Off
No power output.
Solid green
Power output is operational.
FAIL
Off
The power supply is operational.
Solid red
The power supply fails.
Specifications
Module type
RG-PD1200
RG-PD2000
Rated
Voltage
Range
-36VDC to -72VDC
-36VDC to -72VDC
Maximum
Output Power
1200W
2000W
Power Cable
63A
80A
RG-S8614/S8610/S8606/S8606 B system supports 1+1 redundancy for the power supply. For higher stability and
reliability of the entire system, you are recommended to configure 1+1 power module redundancy for the
RG-S8614/S8610/S8606/S8606 B.
Содержание RG-S8614
Страница 1: ...RG S8600 Series Switch Hardware Installation and Reference Guide V1 78 ...
Страница 58: ...Figure 2 3 Moving the RG S8606 Switch Figure 2 4 Moving the RG S8606 B Switch ...
Страница 62: ...Figure 2 6 Ventilation of RG S8614 ...
Страница 63: ...Figure 2 7 Ventilation of RG S8610 Figure 2 8 Ventilation of RG S8606 ...
Страница 76: ...Figure 3 8 Installing the Power Supply of the RG S8606 Switch ...
Страница 92: ...Figure 3 34 Board Components of the RG S8610 Figure 3 35 Board Components of RG S8606 ...
Страница 116: ......