3.11. DateTime
Description
Set the date, time and time zone information for this system.
Properties
TimeZone
Specifies the time zone. (Default: GMT)
DSTEnabled
Enable daylight saving time. (Default: Yes)
DSTOffset
Daylight saving time offset in minutes. (Default: 60)
DSTStartMonth
What month daylight saving time starts. (Default:
March)
DSTStartDay
What day of month daylight saving time starts.
(Default: 1)
DSTEndMonth
What month daylight saving time ends. (Default:
October)
DSTEndDay
What day of month daylight saving time ends.
(Default: 1)
TimeSynchronization
Enable time synchronization. (Default: Disable)
TimeSyncServerType
Type of server for time synchronization, UDPTime
or SNTP (Simple Network Time Protocol). (Default:
SNTP)
TimeSyncServer1
DNS hostname or IP Address of Timeserver 1.
TimeSyncServer2
DNS hostname or IP Address of Timeserver 2.
(Optional)
TimeSyncServer3
DNS hostname or IP Address of Timeserver 3.
(Optional)
TimeSyncInterval
Seconds between each resynchronization. (Default:
86400)
TimeSyncMaxAdjust
Maximum time drift in seconds that a server is al-
lowed to adjust. (Default: 600)
TimeSyncGroupIntervalSize
Interval according to which server responses will be
grouped. (Default: 10)
Comments
Text describing the current object. (Optional)
Note
This object type does not have an identifier and is identified by the name of the type
only. There can only be one instance of this type.
3.11. DateTime
Chapter 3. Configuration Reference
100
Содержание NetDefend DFL-260E
Страница 18: ...1 6 User roles Chapter 1 Introduction 18...
Страница 75: ...2 4 5 script Chapter 2 Command Reference 75...
Страница 139: ...Comments Text describing the current object Optional 3 32 IPsecAlgorithms Chapter 3 Configuration Reference 139...
Страница 195: ...3 55 UserAuthRule Chapter 3 Configuration Reference 195...