72
First, connect the system and APC UPS via RS-232 for communication. Then set up the
shutdown values (shutdown battery level %) when power is failed. UPS in other
companies can work well, but they have no such communication feature with the system.
Figure 4.5.2.2
(Figure 4.5.2.2: With Smart-UPS.)
UPS column description:
UPS Type
Select UPS Type. Choose Smart-UPS for APC, None for other
vendors or no UPS.
Shutdown
Battery
Level (%)
When below the setting level, system will shutdown. Setting
level to “0” will disable UPS.
Shutdown
Delay (s)
If power failure occurs, and system power can not recover, the
system will shutdown. Setting delay to “0” will disable the
function.
Shutdown
UPS
Select ON, when power is gone, UPS will shutdown by itself after
the system shutdown successfully. After power comes back, UPS
will start working and notify system to boot up. OFF will not.
Status
The status of UPS:
“Detecting…”
“Running”
“Unable to detect UPS”
“Communication lost”
“UPS reboot in progress”