121
INFO
Volt recovery
Voltage of <string> in JBOD <string> is NORMAL
WARNING Therm warn OT
Temperature of <string> read as <string> in JBOD <name>
is OT WARNING
WARNING Therm warn UT
Temperature of <string> read as <string> in JBOD <name>
is UT WARNING
WARNING Therm fail OT
Temperature of <string> read as <string> in JBOD <name>
is OT FAILURE
WARNING Therm fail UT
Temperature of <string> read as <string> in JBOD <name>
is UT FAILURE
INFO
Therm recovery
Temperature of <string> in JBOD <name> is NORMAL
System maintenance events
Level Type
Description
INFO
System shutdown
System shutdown.
INFO
System reboot
System reboot.
INFO
System console
shutdown
System shutdown from <string> via Console UI
INFO
System web
shutdown
System shutdown from <string> via Web UI
INFO
System button
shutdown
System shutdown via power button
INFO
System LCM
shutdown
System shutdown via LCM
INFO
System console
reboot
System reboot from <string> via Console UI
INFO
System web reboot
System reboot from <string> via Web UI
INFO
System LCM reboot
System reboot via LCM
INFO
FW upgrade start
System firmware upgrade starts.
INFO
FW upgrade
success
System firmware upgrade succeeds.
WARNING FW upgrade failure System firmware upgrade is failed.
ERROR
IPC FW upgrade
timeout
System firmware upgrade timeout on another controller
INFO
Config imported
<string> config imported
HAC events
Level Type
Description
INFO
RG owner changed The preferred owner of RG <name> has been changed to
controller <number>.
INFO
Force CTR write
through
Controller <number> forced to adopt write-through mode on
failover.
INFO
Restore CTR cache
mode
Controller <number> restored to previous caching mode on
failback.
INFO
Failover complete
All volumes in controller <number> completed failover
process.
INFO
Failback complete
All volumes in controller <number> completed failback
process.
INFO
CTR inserted
Controller <number> is inserted into system
ERROR
CTR removed
Controller <number> is removed from system
ERROR
CTR timeout
Controller <number> gets no response
ERROR
CTR lockdown
Controller <number> is locked down
Содержание DSN-6110
Страница 70: ...70 4 5 1 Hardware monitor Hardware monitor can view the information of current voltages and temperatures ...
Страница 128: ...128 Figure B 4 Figure B 5 8 Click OK Figure B 6 Figure B 7 ...
Страница 134: ...134 Step 3 Click confirm The system will ask you to shutdown Please shutdown IP SAN storage Click Ok ...