Prepare Your Server
A. this guide assumes that Microsoft windows 2003 Server or later will be used for product set
up. the server must have a 10/100/1000 Gbps NIC. All updates, Service Packs, and drivers
for the operating system and NIC must be installed. your server will need to install the latest
supported version of Microsoft iSCSI initiator software. the software can be downloaded
from http://www.microsoft.com/downloads
B. your server will need to install the latest supported version of Java Runtime Environment 6
(JRE 6) or later version. the Java software is available at: http://java.com
C. the DSN series SAN array management port has an IP address of
192.168.1.1
. therefore,
the NIC of your server must have a fixed IP address of 192.168.1.x (e.g., 192.168.1.2). After
you set up the SAN array via the web-based wizard, you can change the management port
to the desired IP address.
Note
: Attempting to install the Java Runtime Environment 6 on a non supported version of
windows or a computer whose Service Packs are out of date will display an error
message.
First-Time Startup
A. Power up the SAN array. the system will start to boot:
•
the left (Power) LED turns green when power is applied.
• The SAN array goes through its power-on procedure, which takes up to five minutes, after which
the right (Ready/Fault) LED turns green.
B. Point your web browser on the management computer to the following default IP address:
192.168.1.1
C. when the Start-up wizard’s welcome screen appears, click the
“
I Accept the End User License Agreement
” button.
D. At the Administrator Account screen, enter a case-sensitive password for the administrator
account, if you wish to change the default value. the default username is
admin
and the default
password is
admin
. Click
Next
.
E. At the Management Port screen, enter the IP address, subnet mask, and default gateway that
computers will use to access the management port. Change the host name if desired. Click
Next
.
F. At the Data Port screen, enter the IP address, subnet mask, and default gateway for each iSCSI
data port. you can skip any or all of these items, and assign them later. Click
Next
or “
Skip To
Email Notification
”.
G. At the Email Notification screen, enable email notifications. Enter an SMTP server IP address
and port number, return email address, and email address where alerts are to be sent. Click
Next
.
D. the diagnostic port can optionally be used for diagnostics. It connects to an RS-232C port on your
host computer configured for a baud rate of 9600bps at eight data bits, no parity bit, one stop bit and
no hardware handshake, using a standard DB9 cable.