Supported Accessories 

DIS-200G Series Accessories 

DIS-RK200G 

Standard 19” rack mounting kit  

DIS-PWR40AC 

40 W, 100 ~ 240 V AC input, 12 V DC output power adapter with 60 °C operating temperature 

DIS-PWR180AC 

180 W, 100 ~ 240 V AC input, 54 V DC output power adapter with 60 °C operating temperature 

DIS-200G-RPK40 

Rack mounting kit and 40 W, 100 ~ 240 V AC input, 12 V DC output power adapter with 60 °C operating temperature 

DIS-200G-RPK180 

Rack mounting kit and 180 W, 100 ~ 240 V AC input, 54 V DC output power adapter with 60 °C operating temperature 

 

Supported SFP Transceivers 

Optional SFP Transceivers 

DEM-310GT 

1000BASE-LX, single-mode, 10 km, 0 to 70 °C operating temperature 

DIS-S310LX 

1000BASE-LX, single-mode, 10 km, -40 to 85 °C operating temperature 

DEM-311GT 

1000BASE-SX, multi-mode, 550 m, 0 to 70 °C operating temperature 

DIS-S301SX 

1000BASE-SX, multi-mode, 550 m, -40 to 85 °C operating temperature 

DEM-312GT2 

1000BASE-SX, multi-mode, 2 km, 0 to 70 °C operating temperature 

DIS-S302SX 

1000BASE-SX, multi-mode, 2 km, -40 to 85 °C operating temperature 

DEM-314GT 

1000BASE-LHX, single-mode, 50 km, 0 to 70 °C operating temperature 

DIS-S330EX 

1000BASE-EX, single-mode, 30 km, -40 to 85 °C operating temperature 

DIS-S350LHX 

1000BASE-LHX, single-mode, 50 km, -40 to 85 °C operating temperature 

DIS-S380ZX 

1000BASE-ZX, single-mode, 80 km, -40 to 85 °C operating temperature 

 

Optional Accessories 

Optional Accessories 

DPE-SP110 

Outdoor PoE Ethernet Surge Protector 

DPE-SP110I 

Ethernet Surge Protector 

 

Содержание Dis-200G Series

Страница 1: ......

Страница 2: ...ither the entities claiming the marks and names or their products D Link Corporation disclaims any proprietary interest in trademarks and trade names other than its own 2018 D Link Corporation All rig...

Страница 3: ...example press the Enter key Blue Courier Font This convention is used to represent a Command Line Interface CLI example Notes and Cautions NOTE A note indicates important information that helps you m...

Страница 4: ...ngs limit for the extension cable or power strip To help protect the system from sudden transient increases and decreases in electrical power use a surge suppressor line conditioner or uninterruptible...

Страница 5: ...o not overload the AC supply branch circuit that provides power to the rack The total rack load should not exceed 80 percent of the branch circuit rating Ensure that proper airflow is provided to comp...

Страница 6: ...Switch on a Wall 14 Using the Wall Mounting Brackets 14 Using the Screw Hooks 15 Installing the Switch into a Rack 16 Grounding the Switch 16 Installing Transceivers into the Transceiver Ports 17 Conn...

Страница 7: ...e Web UI 32 Web Pages 32 Appendix A Technical Specifications 34 General 34 Software Features 35 Supported Accessories 37 Supported SFP Transceivers 37 Optional Accessories 37 Appendix B Cables and Con...

Страница 8: ...llance settings The DIS 200G Series furthermore integrates advanced management and security functions to provide a complete solution The DIS 200G Series consists of the following switch models DIS 200...

Страница 9: ...ich is used to connect to the DIS 200G switch using a RJ 45 to serial cable 3 Ports 1 10 These are 10 100 1000 Mbps ports that can be used to connect to any device using a standard Category 5 5e RJ 45...

Страница 10: ...er adapter to the switch Top Panel Components Figure 1 3 Top panel view of the DIS 200G Series switches Ports that can be found on the top panel of this switch are listed in the table below LED Descri...

Страница 11: ...ections Blinking green A firmware update is in progress Solid amber The DIS 200G switch is not ready for communication Blinking amber The DIS 200G switch is booting up or PoE has failed during system...

Страница 12: ...he power budget is between 25 and 0 but still has more than 15 4 W of power remaining Blinking amber The power budget is between 25 and 0 and has less than 15 4 W of power remaining 2 Left Ports 1 10...

Страница 13: ...olid green Port is connected at 1 Gbps Blinking green The port is undergoing cable diagnostics Solid amber Port is connected at 10 100 Mbps 2 Right Ports 1 8 Blinking green There is activity on the po...

Страница 14: ...please ensure that the DIN rail is level and that the DIN rail mounting kit is installed correctly on the DIS 200G switch Use the following instructions to install the DIS 200G switch on a DIN rail 1...

Страница 15: ...secure the switch to the wall using the appropriate screws for the wall anchors Using the Screw Hooks Use the following instructions to mount the DIS 200G switch on a wall using the screw hooks on th...

Страница 16: ...the provided screws Figure 2 3 Attaching rack mount brackets to the Switch 2 Use the screws that were provided with the rack to install the switch in the rack Figure 2 4 Installing the Switch in a Rac...

Страница 17: ...nnect various other networking devices to this switch that do not support the standard RJ 45 wiring connection These ports are generally used to connect this switch to optical fiber connections and ca...

Страница 18: ...ector on the back of the switch Connect the other end of the power adapter to a main power source Figure 2 6 Connecting the power adapter Using the Terminal Connections Before proceeding ensure that a...

Страница 19: ...utomatically be designated as the main power source Any additional power sources connected afterwards will be designated redundant power sources When one of the power source is behaving abnormally or...

Страница 20: ...cate that network activity is taking place on that port The diagram below displays a typical end node connected to the switch Figure 3 1 Connecting the Switch to an End Node Switch to Another Switch T...

Страница 21: ...DIS 200G Series Layer 2 Gigabit Industrial Smart Managed Switch Hardware Installation Guide 21 Figure 3 2 Connecting the Switch to another switch hub...

Страница 22: ...as been successfully installed you can begin configuration monitor the LED panel and display graphical statistics using a web browser Supported browsers include Microsoft Internet Explorer Firefox Chr...

Страница 23: ...le port on the switch These are widely available and can be easily downloaded from the Internet You need the following equipment to use the console port of your device A PC with both an RS 232 serial...

Страница 24: ...ppear in the terminal 3 tests completed successfully RedBoot fis load d managed Image loaded from 0x80040000 0xB12d1d30 RedBoot go Press ENTER to get started After the boot sequence has been completed...

Страница 25: ...t for the switch called user Switch enable Switch configure terminal Switch config username user password pass1234 Switch config In the example above 1 At the CLI command prompt enter the enable comma...

Страница 26: ...com to download the software and get more information The Simple Network Management Protocol SNMP is an OSI Layer 7 Application Layer protocol designed specifically for managing and monitoring network...

Страница 27: ...d or restricted are defined using the Object Identifier OID associated with a specific MIB An additional layer of security is available for SNMPv3 in that SNMP messages may be encrypted Traps Traps ar...

Страница 28: ...web browsers are supported Internet Explorer Firefox Google Chrome Safari Logging into the Web UI To access the Web UI open a standard web browser enter the switch s default IP address 10 90 90 90 in...

Страница 29: ...elect this option to obtain IP address settings from a DHCP server IP Address If you selected Static enter the IP address of the switch here Netmask If you selected Static select the netmask here Gate...

Страница 30: ...word Enter the new password again for confirmation Tick the Ignore the wizard next time option to skip the Smart Wizard on the next login Click the Exit button to discard the changes made exit the Sma...

Страница 31: ...lick the Exit button to discard the changes made exit the Smart Wizard and continue to the Web UI Click the Back button to discard the changes made and return to the previous step Click the Apply Save...

Страница 32: ...n them to display windows AREA 2 Presents switch status based on user selection and the entry of configuration data In addition a hyperlink to Settings is offered to enable quick Gateway configuration...

Страница 33: ...this folder Security Features regarding the switch s security can be viewed and configured in this folder OAM Features regarding the switch s Operations Administration and Maintenance OAM can be viewe...

Страница 34: ...Interface Exchange Auto MDI MDIX adjustment for all twisted pair ports Performance Switching Capacity 24 Gbps Maximum Forwarding Rate 17 85 Mpps MAC Address Table Size Up to 8K entries Transmission M...

Страница 35: ...0 to 65 C 40 to 149 F 40 to 75 C 40 to 167 F Storage Temperature 40 to 85 C 40 to 185 F Operating Humidity 0 to 95 RH non condensing Storage Humidity 0 to 95 RH non condensing Material IP30 rated meta...

Страница 36: ...s per port Queue handling Strict Priority Queue SPQ Weighted Round Robin WRR Port based bandwidth control rate limiting Ingress 8 kbps Egress 64 kbps Security D Link Safeguard Traffic segmentation Bro...

Страница 37: ...Transceivers DEM 310GT 1000BASE LX single mode 10 km 0 to 70 C operating temperature DIS S310LX 1000BASE LX single mode 10 km 40 to 85 C operating temperature DEM 311GT 1000BASE SX multi mode 550 m 0...

Страница 38: ...view these products for matching cable pin assignment The following diagrams and tables show the standard RJ 45 socket connector and their pin assignments Figure B 1 Standard RJ45 socket and connector...

Страница 39: ...to the console port of the switch to access the command line interface The following diagram and table show the standard RJ 45 to RS 232 cable and pin assignments Figure B 2 Console to RJ45 Cable Cont...

Страница 40: ...ged Switch User Manual This manual describes the general installation and how to connect the switch in various scenarios Online Support If there are any issues that are not in the user manual please v...

Страница 41: ...the equipment Caution This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must ac...

Страница 42: ...rn die W rme erzeugen Trennen Sie das Produkt immer von der Stromzufuhr bevor Sie es reinigen und verwenden Sie dazu ausschlie lich ein trockenes fusselfreies Tuch CONSIGNES DE S CURIT Les consignes g...

Страница 43: ...alore Scollegare sempre il prodotto dalla presa elettrica prima di pulirlo e usare solo un panno asciutto che non lasci filacce VEILIGHEIDSINFORMATIE De volgende algemene veiligheidsinformatie werd ve...

Страница 44: ...r Verpackung helfen Sie die Umwelt zu schonen und die menschliche Gesundheit zu sch tzen D Link und die Umwelt D Link ist sich den m glichen Auswirkungen seiner Gesch ftst tigkeiten und seiner Produkt...

Страница 45: ...tto ambientale visitate il sito all indirizzo www dlinkgreen com NEDERLANDS NL Dit symbool op het product of de verpakking betekent dat dit product volgens de plaatselijke wetgeving niet mag worden we...

Страница 46: ...gol sainkr l tov bbi inform ci kat a www dlinkgreen com weboldalon tudhat meg NORSK NO Dette symbolet p produktet eller forpakningen betyr at dette produktet if lge lokale lover og forskrifter ikke sk...

Страница 47: ...t bevara milj n och skydda m nniskors h lsa D Link och milj n P D Link f rst r vi och r fast beslutna att minska den p verkan v ra verksamheter och produkter kan ha p milj n F r att minska denna p ver...

Отзывы: