D-Link DGS-6604 Modular Switch
u
9
EN
G
LIS
H
Figure 10. Installation Check
Installation Check
Verify that the external AC power supply
provides the correct voltage and frequency.
Verify that the cabinet has been fastened
completely, and does not move or tilt.
Verify that the Power Supplies, CM and Line
Cards have been installed in the chassis.
Verify that the optical fiber and twisted pair
cables match their respective interfaces.
Verify that the cables have been bound
appropriately and are not subject to any
excess stress.
Verify that the power cables are in good
condition and comply with safety requirements.
Verify that the power module has been firmly
installed into the backplane connector.
Turn on the power switch and verify that the
power module is operating correctly.
Unpacking Inspection
Requirements
Checklist
1. DGS-6604 Chassis Carton
• DGS-6604 Chassis (no cards installed)
1. Card Module Carton (s)
• 1 CM Card DGS-6600-CM
• Line Cards (specific per order)
• Power Supplies Units (number specific per
order)
2. DGS-6604 Accessories Carton including:
• AC Power Cord
• RS-232 Console Cable (9 pin D-Sub)
• USB Console Cable (Type A to Type B)
• Fan Tray
• Air Filter
• CD software and manual
• QIG
Management Options
The system may be managed out-of-band
through the console port(s) and Ethernet port
on the Control Module or in-band using Telnet/
SSH. Each Switch must be assigned its own IP
address, which is used for communication with
an SNMP network manager or other TCP/IP
application (for example BOOTP, TFTP). The
Switch’s default IP address is 10.90.90.90 (out-
of-band IP address). The user can change the
default IP address to meet the specifications of
your networking address scheme.
Connecting the Console Port (USB or 9
Pin D-Sub)
The switch provides a USB or 9 Pin D-Sub
Serial Connection to a computer or terminal
for monitoring and configuration. To use
the console port, you need the following
equipment:
• A terminal or a computer with a 9 pin serial
port /USB port and the ability to emulate a
terminal.
• A null modem or cross-over RS-232 cable
with a female DB-9 connector for the
switch’s console port.
- or -