background image

 

 
 
 
 
 
 

 

 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Technical Support

 

 

この度は弊社製品をお買い上げいただき、誠にありがとうご

ざいます。 

 

下記弊社

Web

サイトからユーザ登録及び新製品登録を 

行っていただき、ダウンロードサービスにて 

サポート情報、ファームウェア、ユーザマニュアルを 

ダウンロードすることができます。 

 

ディーリンクジャパン  Web サイト 

URL:http://www.dlink-jp.com 

 

Содержание DGS-3620-28SC-EI

Страница 1: ......

Страница 2: ... may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate m...

Страница 3: ...24 Installing the Switch in a rack 24 Mounting the Switch in a Standard 19 Rack 25 Power On 25 Power Failure 25 Installing SFP and SFP Ports 26 Connecting to a Redundant Power Supply 28 External Redundant Power System 29 DPS 900 29 DPS 800 30 Chapter 3 Connecting the Switch 32 Switch to End Node 32 Switch to Switch 32 Connect to a Network Backbone or Server 33 Chapter 4 Introduction to Switch Mana...

Страница 4: ...tion Guide iv Appendix Section 42 Appendix A Technical Specifications 42 General 42 Physical and Environmental 42 Performance 43 Port Functions 44 Appendix B Cables and Connectors 45 Ethernet Cable 45 Console Cable 46 Redundant Power Supply RPS Cable 47 Warranties Technical Support ...

Страница 5: ...present filenames program names and commands For example use the copy command Boldface Typewriter Font Indicates commands and responses to prompts that must be typed exactly as printed in the manual Initial capital letter Indicates a window name Names of keys on the keyboard have initial capitals For example Click Enter Italics Indicates a window name or a field Also can indicate a variables or pa...

Страница 6: ...overs or touching internal components Operate the product only from the type of external power source indicated on the electrical ratings label If unsure of the type of power source required consult your service provider or local power company To help avoid damaging the system be sure the voltage selection switch if provided on the power supply is set to match the power available at the Switch s l...

Страница 7: ...t one time The weight of more than one extended component could cause the rack to tip over and may result in serious injury Before working on the rack make sure that the stabilizers are secured to the rack extended to the floor and that the full weight of the rack rests on the floor Install front and side stabilizers on a single rack or front stabilizers for joined multiple racks before working on...

Страница 8: ...he chassis The following steps can also be taken prevent damage from electrostatic discharge ESD 1 When unpacking a static sensitive component from its shipping carton do not remove the component from the antistatic packing material until ready to install the component in the system Just before unwrapping the antistatic packaging be sure to discharge static electricity from your body 2 When transp...

Страница 9: ...15GT 1000BASE ZX Single mode 80km DGS 712 1000BASE TX DEM 330T R 1000BASE BX WDM transceiver Single Mode 10km DEM 331T R 1000BASE BX WDM transceiver Single Mode 40km DEM 210 100Base FX Multi mode 2km DEM 211 100Base FX Single mode 15km DEM 220T 100Base BX Wavelength Tx 1550nm Rx 1310nm Single mode 20km DEM 220R 100Base BX Wavelength Tx 1310nm Rx 1550nm Single mode 20km All D Link DGS 3620 Series s...

Страница 10: ...Log support Maximum packet forwarding rate 130 95Mpps High performance switching engine performs forwarding and filtering at full wire speed up 176Gbps Full and half duplex for all ports Full duplex allows the switch port to simultaneously transmit and receive data It only works with connections to full duplex capable end stations and switches Connections to a hub must take place at half duplex Su...

Страница 11: ...000 Base T SFP 4 Port 10GE SFP 20 Port 10 100 1000Mbps 4 Combo 10 100 1000 Base T SFP 4 Port 10GE SFP with DC power 20 Port SFP 4 Combo 10 100 1000 Base T SFP 4 Port 10GE SFP 20 Port SFP 4 Combo 10 100 1000 Base T SFP 4 Port 10GE SFP with DC power 20 Port 10 100 1000Mbps with PoE 4 Combo 10 100 1000 Base T SFP 4 Port 10GE SFP 48 Port 10 100 1000Mbps 4 Port 10GE SFP 48 Port 10 100 1000Mbps with PoE...

Страница 12: ... Base T SFP Four SFP ports SD Card slot 2 Digital in and 1 Digital out Alarm connector LEDs for Power Console RPS SD card slot MGMT and Link Act Speed for each port Console and Management Port DGS 3620 28TC DC Figure 1 2 Front panel view of a DGS 3620 28TC DC Switch Twenty 10 100 1000BASE T ports Four Combo 10 100 1000 Base T SFP Four SFP ports SD Card slot 2 Digital in and 1 Digital out Alarm con...

Страница 13: ...out Alarm connector LEDs for Power Console SD Card slot MGMT and Link Act Speed for each port Console and Management Port DGS 3620 28PC Figure 1 5 Front panel view of a DGS 3620 28PC Switch Twenty 10 100 1000 PoE Base T Four Combo 10 100 1000 Base T SFP Four SFP ports SD Card slot 2 Digital in and 1 Digital out Alarm connector LEDs for Power Console RPS SD Card slot MGMT PoE and Link Act Speed for...

Страница 14: ... and Link Act Speed for each port NOTE The alarm PIN s 1 2 and 3 works under 60V while pins 4 5 6 and 7 works under 3V CAUTION The alarm port on the DGS 3620 Series is provided to trigger external events that may affect the switch These could be fan or temperature failures Connect the alarm input pins on the switch to the alarm output terminals on other devices Connect the alarm output pins on ext...

Страница 15: ...e Light off No link Red Solid light Read Write failure RPS Green Solid light RPS in use Light off RPS off Blinking When the switch detects that the RPS cable is connected Link Act Speed Green Solid light Each Port functions like this when the LED is in Link Act Speed mode PoE Green Solid Light Each Port functions like this when the LED is in PoE mode Stacking ID Green 1 12 H or h When the switches...

Страница 16: ...eption or transmission i e Activity Act of data occurring at a 1000Mbps port Orange Solid light When there is a secure connection or link to 100Mbps Ethernet device at any of the ports Blinking When there is reception or transmission i e Activity Act of data occurring at a 100Mbps port Off Light off No Link SFP Port Link Act Green Solid light When there is a secure connection or link to 10G bps Et...

Страница 17: ...SD Card Management Figure 2 1 LED indicators for a DGS 3620 28TC Switch DGS 3620 28TC DC LED Panel Power Console SD Card Management Figure 2 2 LED indicators for a DGS 3620 28TC DC Switch DGS 3620 28SC LED Panel Power Console RPS SD Card Management Figure 2 3 LED indicators for a DGS 3620 28SC Series Switch DGS 3620 28SC DC LED Panel Power Console SD Card Management ...

Страница 18: ...0 28SC DC Switch DGS 3620 28PC LED Panel Power Console RPS SD Card LINK ACT SPD POE Management Figure 2 5 LED indicators for a DGS 3620 28PC Switch DGS 3620 52T LED Panel Power Console RPS SD Card Management Figure 2 6 LED indicators for a DGS 3620 52T Switch DGS 3620 52P LED Panel Power Console RPS SD Card LINK ACT SPD POE Management ...

Страница 19: ...xStack DGS 3620 Series Layer 3 Managed Stackable Gigabit Switch Hardware Installation Guide 19 Figure 2 7 LED indicators for a DGS 3620 52P Switch ...

Страница 20: ...ternal power fails the Redundant Power Supply RPS takes over power responsibilities similar to a UPS system DGS 3620 28TC DC Figure 3 2 Rear panel view of a DGS 3620 28TC DC Switch NOTE The DGS 3620 28TC does not support the Redundant Power Supply function even thought it has the device on the back panel DGS 3620 28SC Figure 3 3 Rear panel view of a DGS 3620 28SC Switch On the left side of the DGS...

Страница 21: ...is the Redundant Power Supply jack Use this accessory as backup power When the internal power fails the Redundant Power Supply RPS takes over power responsibilities similar to a UPS system On the right side of the device are two RJ 45 ports one for management and the other for the console There is also an alarm port to attach a General I O Terminal block This accessory can give better security pro...

Страница 22: ...tion system components might overheat which could lead to system failure or even severely damaged components The following switches have similar side panels and two fans DGS 3620 28TC DGS 3620 28TC DC DGS 3620 28SC DGS 3620 28SC DC Figure 4 1 Side panels of the DGS 3260 28TC Switch The DGS 3620 52T is the only DGS 3620 Series switch with three fans DGS 3620 52T Figure 4 2 Side panels of the DGS 32...

Страница 23: ...idelines Please follow these guidelines for setting up the Switch Install the Switch on a sturdy level surface that can support at least 6 6 lb 3kg This is without PoE functionality of weight Do not place heavy objects on the Switch The power outlet should be within 1 82 meters 6 feet of the Switch Visually inspect the power cord and see that it is fully secured to the AC power port Make sure that...

Страница 24: ...e 2 1 Attach rubber feet to the switch Installing the Switch in a rack The Switch is mounted to a standard 19 rack using mounting brackets Use the following diagrams as a guide Figure 2 2 Attach mounting brackets to the switch Fasten the mounting brackets to the Switch using the screws provided With the brackets attached securely the Switch can be mounted in a standard rack as shown below Note Ple...

Страница 25: ...r On 1 Plug one end of the AC power cord into the power connector of the Switch and the other end into the local power source outlet 2 Once the system is powered on the LED s blink green to indicate that the system is resetting Power Failure In the event of a power failure just as a precaution unplug the Switch After the power returns plug the switch back in to the power socket ...

Страница 26: ... 220T 100Base BX Wavelength Tx 1550nm Rx 1310nm Single mode 20km DEM 220R 100Base BX Wavelength Tx 1310nm Rx 1550nm Single mode 20km The following list of tranceivers or cables is supported in the SFP ports DEM 431XT 10GBASE SR SFP Transceiver 80m OM1 OM2 MMF 300m OM3 MMF DEM 431XT DD 10GBASE SR SFP Transceiver 80m OM1 OM2 MMF 300m OM3 MMF DEM 432XT 10GBASE LR SFP Transceiver 10km DEM 432XT DD 10G...

Страница 27: ...xStack DGS 3620 Series Layer 3 Managed Stackable Gigabit Switch Hardware Installation Guide 27 Figure 2 4 Inserting fiber optic transceivers into a DGS 3620 Series Switch ...

Страница 28: ...the switch and the other end into the redundant power supply 2 Using a standard AC power cable connect the redundant power supply to the main AC power source A green LED on the front of the DPS 500 will glow to indicate a successful connection 3 Re connect the switch to the AC power source The LED indicator will show that a redundant power supply is now in operation 4 Do not make any changes on th...

Страница 29: ...e DPS 900 is a standard size rack mount 5 standard units in height designed to hold up to eight DPS 500 redundant power supplies However it cannot hold eight DGS 700 modules Figure 2 6 Inserting the DPS 500 into the DPS 900 The RPS can be mounted in a standard 19 rack Use the following diagram to guide you CAUTION DO NOT connect the RPS to AC power before the DC power cable is connected This might...

Страница 30: ...y injury under certain circumstances Therefore always install the stabilizers before installing components in the rack After installing components in a rack do not pull more than one component out of the rack on its slide assembly at a time The weight of more than one extended component could cause the rack to tip over and may result in injury DPS 800 The DPS 800 is a standard size rack mount 1 st...

Страница 31: ...d Stackable Gigabit Switch Hardware Installation Guide 31 Figure 2 8 Install the DPS 500 in the DPS 800 The RPS can be mounted in a standard 19 rack Use the following diagram to guide you Figure 2 9 Install the DPS 800 in an Equipment Rack ...

Страница 32: ...he Switch The Link Act LEDs for each Ethernet port turns green or amber when the link is active A blinking LED indicates packet activity on that port Figure 3 1 Connect a DGS 3620 Series Switch to an end node Switch to Switch There is a great deal of flexibility on how connections are made using the appropriate cabling Connect a 10BASE T switch port to the Switch via a twisted pair Category 3 4 or...

Страница 33: ...e ideal for uplinking to a network backbone server or server farm The copper ports operate at a speed of 10 100 1000Mbps in half or full duplex mode The fiber optic ports can operate at both 100Mbps and 1000Mbps in full duplex mode You can connect to the Gigabit Ethernet ports using a fiber optic cable or a Category 5E copper cable depending on the type of port The Link LED turns green when a conn...

Страница 34: ...ial console port to access the DGS 3620 range The command line interface provides complete access to all DGS 3620 Series of switches management features Connecting the Console Port The console port on the front panel of the DGS 3620 Series is used to connect a computer that monitors and configures the switch The console port is an RJ 45 port and requires a special cable that is included with the s...

Страница 35: ...le making a connection make sure the emulation is set to VT 100 The emulation settings can be configured by 1 Click File Menu in HyperTerminal 2 Click Properties from the drop down menu 3 Click the Settings Tab This is where you will find the Emulation options If you still do not see anything try rebooting the Switch by disconnecting its power supply Once connected to the console the image in Figu...

Страница 36: ...Series Switch Connecting to the Management Port The front panel of the DGS 3620 Series Switch features an out of band RJ 45 Management port which can easily connect to a notebook Connect to the out of bound management console using a web browser or Telnet command prompt interface This is the default login interface and is the tool you can use when connecting to the DGS 3620 Series Switch for the f...

Страница 37: ...s by the factory This MAC address cannot be changed and can be found by entering the command show switch into the command line interface The Switch s MAC address also appears in the Device Information and System Information windows of the Web based management interface The IP address for the Switch must be set before using the Web based manager The Switch IP address can be automatically set using ...

Страница 38: ...s using SNMP v3 Using SNMP v3 individual users or groups of SNMP managers can be allowed to perform or be restricted from performing specific SNMP management functions The functions allowed or restricted are defined using the Object Identifier OID associated with a specific MIB An additional layer of security is available for SNMP v3 in that SNMP messages may be encrypted To read more about how to...

Страница 39: ...gram and Telnet are different ways to access the same internal switching software and configure it Thus all settings encountered in web based management are the same as those found in the console program Logging onto the Web Manager To begin managing the Switch simply run the browser installed on your computer and point it to the IP address you have defined for the device The URL in the address ba...

Страница 40: ...w Area Function AREA 1 Select the folder or window to display Open folders and click the hyperlinked window buttons and subfolders contained within them to display windows AREA 2 Presents a graphical near real time image of the front panel of the Switch This area displays the Switch s ports and expansion modules and shows port activity depending on the specified mode Some management functions incl...

Страница 41: ...s When connecting to the management mode of the Switch with a Web browser a login screen is displayed Enter a user name and password to access the Switch s management mode Note Be sure to configure the user name and password in the User Accounts window before connecting the Switch to the greater network ...

Страница 42: ...etwork Cables Cat 5 Enhanced for 1000BASE T UTP Cat 5 Cat 5 Enhanced for 100BASE TX UTP Cat 3 4 5 for 10BASE T EIA TIA 568 100 ohm screened twisted pair STP 100m Physical and Environmental Feature Detailed Description Internal Power Supply AC input for DGS 3620 28TC 28SC 28PC 52T 52P 100 240 VAC 50 60Hz DC input for DGS 3620 28TC DC 28SC DC 36Vdc 72Vdc Optional Redundant Power Supply One connector...

Страница 43: ...1mm W x 380mm D x 44mm H DGS 3620 28TC 28SC 28TC DC 28SC DC 441mm W x 310mm D x 44mm H Weight Model Weight DGS 3620 28TC 4 15kg DGS 3620 28TC DC 4 15kg DGS 3620 28SC 4 10kg DGS 3620 28SC DC 4 10kg DGS 3620 28PC 5 76kg DGS 3620 52TC 5 13kg DGS 3620 52P 6 30kg EMI CE Class A FCC Class A VCCI Class A C Tick Report Safety UL CB Report Performance Feature Detailed Description Transmission Method Store ...

Страница 44: ...0km DEM 311GT 1000ase SX Mutli mode 550m DEM 312GT2 1000Base SX Multi mode 2km DEM 314GT 1000BASE LHX Single mode 50km DEM 315GT 1000BASE ZX Single mode 80km DGS 712 1000BASE TX DEM 330T R 1000BASE BX WDM transceiver Single Mode 10km DEM 331T R 1000BASE BX WDM transceiver Single Mode 40km DEM 210 100Base FX Multi mode 2km DEM 211 100Base FX Single mode 15km DEM 220T 100Base BX Wavelength Tx 1550nm...

Страница 45: ...E ZR SFP Transceiver 80km DEM 435XT 10GBASE LRM SFP Transceiver 220m OM1 OM2 MMF 300m OM3 MMF DEM 435XT DD 10GBASE LRM SFP Transceiver 220m OM1 OM2 MMF 300m OM3 MMF DEM 436XT BXU 10GBASE LR BiDi SFP Transceiver 20km TX 1270nm RX 1330nm DEM 436XT BXD 10GBASE LR BiDi SFP Transceiver 20km TX 1330nm RX 1270nm SFP Tranceivers Supported DEM 310GT 1000Base LX Single mode 10km DEM 311GT 1000ase SX Mutli m...

Страница 46: ... RD receive 4 1000BASE T 1000BASE T 5 1000BASE T 1000BASE T 6 TD transmit RD receive 7 1000BASE T 1000BASE T 8 1000BASE T 1000BASE T Console Cable When connecting the Switch to a PC a Console cable is necessary The following diagrams and tables show the standard Console to DJ 45 receptacle connector and their pin assignments Figure 5 4 Console to RJ 45 Cable Console RJ 45 Pin Assignments Pin Conso...

Страница 47: ...s for matching cable pins The following diagrams and tables show the standard RPS connector and their pin assignments NOTE The DGS 3620 28PC and the DGS 3620 52P use the RPS 700 and not the RPS 500 Both devices have their own cables included in the package Figure 5 5 Redundant Power Supply RPS Cable DPS 500 DPS 700 RPS Cable Pin Assignments Pin Device DPS 500 1 GND GND 2 NC NC 3 12V 12V 4 12V 12V ...

Страница 48: ...e DPS 700 1 54Vrtn 54Vrtn 2 54V 54V 3 12V 12V 4 12V 12V 5 12V 12V 6 12V 12V 7 NC GND NC GND 8 12vsen 12Ven 9 LS 54v LS 54V 10 54V 54V 11 54Vrtn 54Vrtn 12 GND GND 13 GND NC GND NC 14 RPS Present RPS Present 15 Status_1 RPS PG 16 Status_2 GND 17 RPS PG Status_1 18 GND Status_2 19 12VRTNsen 12VRTNsen 20 LS 12V LS 12V 21 54Vsen 54Vsen ...

Страница 49: ...ation pertaining to the product and in that case the product is being sold As Is without any warranty whatsoever including without limitation the Warranty as described herein notwithstanding anything stated herein to the contrary Submitting A Claim The customer shall return the product to the original purchase point based on its return policy In case the return policy period has expired and the pr...

Страница 50: ...ms Inc Other trademarks or registered trademarks are the property of their respective owners Copyright Statement No part of this publication or documentation accompanying this product may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from D Link Corporation D Link Systems Inc as stipulated by the United ...

Страница 51: ...Registration Register your D Link product online at http support dlink com register Product registration is entirely voluntary and failure to complete or return this form will not diminish your warranty rights ...

Страница 52: ...e warranty period on this product U S and Canadian customers can contact D Link technical support through our website or by phone Tech Support for customers within the United States D Link Technical Support over the Telephone USA 877 DLINK 55 877 354 6555 D Link Technical Support over the Internet http support dlink com Tech Support for customers within Canada D Link Technical Support over the Tel...

Страница 53: ...2 00pm 0 05ppm peak 0 045ppm off peak Times Internet http www dlink co uk ftp ftp dlink co uk Technische Unterstützung Deutschland Web http www dlink de Telefon 49 0 1805 2787 0 14 pro Minute Zeiten Mo Fr 08 30 17 30 Uhr Österreich Web http www dlink at Telefon 43 0 820 480084 0 116 pro Minute Zeiten Mo Fr 08 30 17 30 Uhr Schweiz Web http www dlink ch Telefon 41 0 848 331100 0 08 CHF pro Minute Ze...

Страница 54: ...r minuut Tech Support for customers within Belgium www dlink be 033039971 0 175per minuut spitsuren 0 0875per minuut daluren Technische ondereuning voor klanten in Luxemburg www dlink be 32 70 66 06 40 Asistencia Técnica Asistencia Técnica Telefónica de D Link 34 902 30 45 45 0 067 min De Lunes a Viernes de 9 00 a 19 00 http www dlink es Supporto tecnico Supporto Tecnico dal lunedì al venerdì dall...

Страница 55: ...9 00 do 17 00 Volání je zpoplatněno dle příslušných tarifů Vašeho operátora Technikai Támogatás Tel 06 1 461 3001 Fax 06 1 461 3004 Land Line 14 99 HUG min Mobile 49 99 HUF min email support dlink hu URL http www dlink hu Teknisk Support D Link Teknisk Support over Internett http www dlink no D Link Teknisk telefonsupport 815 69 755 Hverdager 08 00 17 00 Teknisk Support D Link teknisk support over...

Страница 56: ...ter Κεφαλληνίας 64 11251 Αθήνα Τηλ 210 86 11 114 ευτέρα Παρασκευή 09 00 17 00 Φαξ 210 8611114 http www dlink gr support Assistência Técnica Assistência Técnica da D Link na Internet http www dlink pt e mail soporte dlink es Teknisk Support D Link Teknisk Support via Internet http www dlink se D Link Teknisk Support via telefon 0770 33 00 35 Vardagar 08 00 17 00 ...

Страница 57: ...k biz hr Tehnična podpora Zahvaljujemo se vam ker ste izbrali D Link proizvod Za vse nadaljnje informacije podporo ter navodila za uporabo prosimo obiščite D Link ovo spletno stran www dlink eu www dlink biz sl Suport tehnic Vă mulţumim pentru alegerea produselor D Link Pentru mai multe informaţii suport şi manuale ale produselor vă rugăm să vizitaţi site ul D Link www dlink eu www dlink ro ...

Страница 58: ...day 9 30AM to 6 30PM Thursdays 9 30AM to 2 00 PM E mail Support sa dlink me com D Link Middle East Dubai U A E Plot No S31102 Jebel Ali Free Zone South P O Box 18224 Dubai U A E Tel 971 4 8809022 Fax 971 4 8809066 8809069 Technical Support 971 4 8809033 General Inquiries info me dlink me com Tech Support support me dlink me com Egypt 1 Makram Ebeid Street City Lights Building Nasrcity Cairo Egypt ...

Страница 59: ...ne 212 663 72 73 24 Email support na dlink me com Lebanon RMA center Dbayeh Lebanon PO Box 901589 Tel 961 4 54 49 71 Ext 14 Fax 961 4 54 49 71 Ext 12 Email taoun dlink me com Bahrain Technical Support 973 1 3332904 Kuwait Technical Support 965 22453939 965 22453949 Türkiye Merkez İrtibat Ofisi Ayazağa Maslak yolu Erdebil Cevahir İş Merkezi No 5 A Ayazağa Maslak İstanbul Tel 90 212 2895659 Ücretsiz...

Страница 60: ...исимости 169 БЦ XXI Век Тел 375 17 218 13 65 E mail minsk dlink ru Казахстан 050008 г Алматы ул Курмангазы дом 143 уг Муканова Тел факс 7 727 378 55 90 E mail almaty dlink ru Узбекистан 100015 г Ташкент ул Нукусская 89 Тел Факс 998 71 120 3770 150 2646 E mail tashkent dlink ru Армения 0038 г Ереван ул Абеляна 6 1 4 этаж Тел Факс 374 10 398 667 E mail erevan dlink ru Грузия 0162 г Тбилиси проспект ...

Страница 61: ...s siguientes teléfonos de D Link PAIS NUMERO Argentina 0800 12235465 Chile 800 260200 Colombia 01800 9525465 Costa Rica 0800 0521478 Ecuador 1800 035465 El Salvador 800 6335 Guatemala 1800 8350255 México 01800 1233201 Panamá 011 008000525465 Perú 0800 00968 Venezuela 0800 1005767 Soporte Técnico de D Link a través de Internet Horario de atención Soporte Técnico en www dlinkla com e mail soporte dl...

Страница 62: ...br Acionar Garantia para 4 ou mais equipamentos Telefones São Paulo 11 2755 6950 GO 4052 1850 Ligação local Nordeste 0800 7024104 Demais Estados 4062 1850 Ligação local Apenas Modems ADSL Garantia diferenciada vendida pela internet Agilidade e tranquilidade para suas atividades Conheça http garantiapremium dlink com br Atendimento disponível das 9h as 21h de segunda a sexta feira e aos sábados das...

Страница 63: ...方式與D Link台灣 地區技術支援工程師聯絡 D Link 免付費技術諮詢專線 0800 002 615 服務時間 週一至週五 早上9 00到晚上9 00 不含周六 日及國定假日 網 站 http www dlink com tw 電子郵件 dssqa_service dlink com tw 如果您是台灣地區以外的用戶 請參考D Link網站全球各地 分公司的聯絡資訊以取得相關支援服務 產品保固期限 台灣區維修據點查詢 請參考以下網頁說明 http www dlink com tw 產品維修 使用者可直接送至全省聯強直營維修站或請洽您的原購買經銷商 ...

Страница 64: ...okumentasi pengguna dapat diperoleh pada situs web D Link Dukungan Teknis untuk pelanggan Dukungan Teknis D Link melalui telepon Tel 62 21 5731610 Dukungan Teknis D Link melalui Internet Email support dlink co id Website http support dlink co id ...

Страница 65: ...Technical Support この度は弊社製品をお買い上げいただき 誠にありがとうご ざいます 下記弊社 Web サイトからユーザ登録及び新製品登録を 行っていただき ダウンロードサービスにて サポート情報 ファームウェア ユーザマニュアルを ダウンロードすることができます ディーリンクジャパン Web サイト URL http www dlink jp com ...

Страница 66: ...技术支持 办公地址 北京市东城区北三环东路 36 号 环球贸易中心 B 座 26F 02 05 室 邮编 100013 技术支持中心电话 8008296688 028 66052968 技术支持中心传真 028 87300889 各地维修中心地址请登陆官方网站查询 网址 http www dlink com cn 办公时间 周一到周五 早09 00到晚18 00 ...

Страница 67: ... site 1 employee 2 9 10 49 50 99 100 499 500 999 1000 or more 3 What network protocol s does your organization use XNS IPX TCP IP DECnet Others_____________________________ 4 What network operating system s does your organization use D Link LANsmart Novell NetWare NetWare Lite SCO Unix Xenix PC NFS 3Com 3 Open Cisco Network Banyan Vines DECnet Pathwork Windows NT Windows 98 Windows 2000 ME Windows...

Страница 68: ......

Отзывы: