DGS-1250 Series Gigabit Ethernet Smart Managed Switch Web UI Reference Guide
289
Log Description
Severity
Parameter Description:
new_version: Running under which version of STP.
Event Description: Used to record the configuration name and revision level changed in
the MST Configuration Identification.
Log Message: Spanning Tree MST configuration ID name and revision level change
(name:<name> revision level:<revision_level>)
Parameter Description:
name: The name given for a specified MST region.
revision_level: Switches using the same given name but with a different revision level are
considered members of different MST regions.
Informational
Event Description: Use to record action to maps a VLAN(s) to an MST instance.
Log Message: Spanning Tree MST configuration ID VLAN mapping table change
(instance:<Instance-id> add vlan:<startvlanid> [- <endvlanid>])
Parameter Description:
Instance-id: MST instance id. Instance 0 represents for default instance, CIST.
startvlanid: The start vid of add vlan range.
endvlanid: The end vid of add vlan range.
Informational
Event Description: Use to record action to delete a VLAN(s) from an MST instance.
Log Message: Spanning Tree MST configuration ID VLAN mapping table change
(instance:<Instance-id> delete vlan:<startvlanid> [- <endvlanid>])
Parameter Description:
Instance-id: MST instance id. Instance 0 represents for default instance, CIST.
startvlanid: The start vid of delete vlan range.
endvlanid: The end vid of delete vlan range.
Informational
Event Description: Used to record the event that port role change to alternate due to guard
root.
Log Message: Spanning Tree port role change (Instance:<instance-id>, <interface-id>) to
alternate port due to the guard root
Parameter Description:
Instance-id: MST instance id. Instance 0 represents for default instance, CIST.
Interface_id: The port number that detect the event.
Informational
Peripheral
Log Description
Severity
Event Description: Fan Recovered.
Log Message: <fan-descr> back to normal
Parameter Description:
fan-descr: The FAN ID and position.
Critical
Event Description: Fan Fail.
Log Message: <fan-descr> failed
Parameter Description:
fan-descr: The FAN ID and position.
Critical
Event Description: Temperature sensor enters alarm state.
Log Message: <thermal-sensor-descr> detects abnormal temperature <degree>
Parameter Description:
thermal-sensor-descr: The sensor ID and position.
degree: The current temperature.
Critical
Event Description: Temperature recovers to normal.
Log Message: <thermal-sensor-descr> temperature back to normal
Critical
Содержание DGS-1250 Series
Страница 1: ......