D-Link DGS-1100 MP/MPP Series Switch User Manual

 

49 

Parameter 

Description 

Source File 

Enter the source filename and path of the firmware file 
located on the local PC. Alternatively click the 

Browse

 

button to navigate to the location of the firmware file located 
on the local PC. 

Click the 

Upgrade

 button to initiate the firmware upgrade. 

 

Firmware Backup to HTTP 

This window is used to initiate a firmware backup to a local PC using HTTP. 

To view the following window, click 

Tools > Firmware Upgrade & Backup > Firmware Backup to 

HTTP

, as shown below: 

 

Figure 15-3 Firmware Backup to HTTP window 

 

The fields that can be configured are described below: 

Parameter 

Description 

Source 

Select the source image to use for the firmware backup. 

Click the 

Backup

 button to initiate the firmware backup. 

 

 

 

Содержание DGS-1100-10MP

Страница 1: ...1 ...

Страница 2: ...ot installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference...

Страница 3: ...Installation 12 Step 1 Unpacking 12 Packing Contents 12 Step 2 Switch Installation 12 Desktop or Shelf Installation 12 Rack Installation 12 Step 3 Plugging in the AC Power Cord 14 Power Failure 14 Grounding the Switch 14 4 Web based Switch Configuration 16 Management Options 16 Connecting using the Web User Interface 16 Logging onto the Web User Interface 17 Smart Wizard 18 Web User Interface 22 A...

Страница 4: ...guration Restore from HTTP 50 Configuration Backup to HTTP 50 Reset 51 Reboot System 51 16 Appendix A Ethernet Technology 53 Gigabit Ethernet Technology 53 Fast Ethernet Technology 53 Switching Technology 53 17 Appendix B Technical Specifications 55 Hardware Specifications 55 Key Components Performance 55 Port Functions 55 Physical Environment 55 Emission EMI Certifications 55 Safety Certification...

Страница 5: ... presented when you access the web interface of the device For more information please refer to the Web UI Interface Guide for the appropriate mode Other Documentation The documents below are a further source of information in regards to configuring and troubleshooting the switch All the documents are available either from the CD bundled with this switch or from the D Link website Other documents ...

Страница 6: ... should pay special attention to these indicators Each example below provides an explanatory remark regarding each type of indicator NOTE A note indicates important information that helps you make better use of your device NOTICE A notice indicates either potential damage to hardware or loss of data and tells you how to avoid the problem CAUTION A caution indicates a potential for property damage ...

Страница 7: ... switches can change modes between Smart Switch and Surveillance Switch modes making them suitable for a variety of applications A new generation of web user interface design make surveillance options more accessible than ever and the standard web interface ensures that advanced technology is made available in an easy to use interface The DGS 1100 MPP series provides multiple PoE ports that suppor...

Страница 8: ... Solid Amber Indicates that the port is running at 10 100Mbps Light off No link PoE Mode Ports 1 8 Green Indicates that PoE mode is active Amber Indicates that there is an issue with the PoE mode activating properly Light off Indicates that PoE mode is not active Link Act Speed LED Ports 9 10 Solid Green There is a secure 1000Mbps connection at the port Blinking Green There is reception or transmi...

Страница 9: ...wer The power port is where to connect the AC power cord CAUTION The SFP ports should use UL listed Optical Transceiver product Rated Laser Class I 3 3Vdc CAUTION This equipment is to be connected only to PoE networks without routing to the outside plant ...

Страница 10: ...t Solid Amber Indicates that the port is running at 10 100Mbps Light off No link PoE Mode Ports 1 8 Green Indicates that PoE mode is active Amber Indicates that there is an issue with the PoE mode activating properly Light off Indicates that PoE mode is not active Link Act Speed LED Ports 9 10 Solid Green There is a secure 1000Mbps connection at the port Blinking Green There is reception or transm...

Страница 11: ...Power Connect the supplied AC power cable to this port CAUTION The SFP ports should use UL listed Optical Transceiver product Rated Laser Class I 3 3Vdc CAUTION This equipment is to be connected only to PoE networks without routing to the outside plant ...

Страница 12: ...n Indicates that PoE mode is active Amber Indicates that there is an issue with the PoE mode activating properly Light off Indicates that PoE mode is not active Link Act Speed LED Ports 25 26 Solid Green There is a secure 1000Mbps connection at the port Blinking Green There is reception or transmission occurring at the port Solid Amber Indicates that the port is running at 10 100Mbps Light off No ...

Страница 13: ...GS 1100 26MP Rear Panel Power Connect the supplied AC power cable to this port CAUTION The SFP ports should use UL listed Optical Transceiver product Rated Laser Class I 3 3Vdc CAUTION This equipment is to be connected only to PoE networks without routing to the outside plant ...

Страница 14: ...en Indicates that PoE mode is active Amber Indicates that there is an issue with the PoE mode activating properly Light off Indicates that PoE mode is not active Link Act Speed LED Ports 25 26 Solid Green There is a secure 1000Mbps connection at the port Blinking Green There is reception or transmission occurring at the port Solid Amber Indicates that the port is running at 10 100Mbps Light off No...

Страница 15: ...GS 1100 26MPP Rear Panel Power Connect the supplied AC power cable to this port CAUTION The SFP ports should use UL listed Optical Transceiver product Rated Laser Class I 3 3Vdc CAUTION This equipment is to be connected only to PoE networks without routing to the outside plant ...

Страница 16: ...tarted Guide One CD with User Manual Step 2 Switch Installation For safe switch installation and operation it is recommended that you Visually inspect the power cord to see that it is secured fully to the AC power connector Make sure that there is proper heat dissipation and adequate ventilation around the switch Do not place heavy objects on the switch Desktop or Shelf Installation When installin...

Страница 17: ...nvironment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer B Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised C Mechanical Loading M...

Страница 18: ...this procedure before powering your switch Required Tools and Equipment Ground screws included in the accessory kit One M4 x 6 mm metric pan head screw Ground cable not included in the accessory kit The grounding cable should be sized according to local and national installation requirements Depending on the power supply and system a 12 to 6 AWG copper conductor is required for U S installation Co...

Страница 19: ... appropriate grounding stud or bolt on rack where the switch is installed Step 6 Verify if the connections at the ground connector on the switch and the rack are securely attached Figure 3 5 Ground cable screw and 8 terminal lug rings CAUTION This equipment is to be connected only to PoE networks without routing to the outside plant ...

Страница 20: ...agent decodes the incoming SNMP messages and responds to requests with MIB objects stored in the database The SNMP agent updates the MIB objects to generate statistics and counters D Link Network Assistant DNA D Link Network Assistant included on the installation CD is a program for discovering DGS 1100 MP MPP Series switches with the same L2 network segment connected to your PC This tool can supp...

Страница 21: ...n a web browser and enter the switch s default IP address into the address bar Make sure that the IP address of the management PC is in the same subnet as the IP address of the switch you are trying to connect to NOTE The default IP address of the switch is 10 90 90 90 with a subnet mask of 255 0 0 0 NOTE The default username is admin and password is admin After successfully connecting to the Web ...

Страница 22: ...tandard Mode and Surveillance Mode on the switch This can be changed at any time by returning to the Smart Wizard For more information on the Standard Mode features of the switch please refer to the Standard Mode Web UI Reference Guide Figure 4 2 Web Mode window The fields that can be configured are described below Parameter Description Web Mode Select the Surveillance Mode option to continue the ...

Страница 23: ...tion In this window the user can configure the IP address assignment method the static IP address netmask and gateway address NOTE The switch will probe IP Cameras every 30 seconds If an IP Camera is not in the same subnet as the switch the IP Camera will not be automatically discovered Place the switch management IP in the same subnet as the IP Cameras for the cameras to be automatically added to...

Страница 24: ...netmask option here Gateway Enter the default gateway IP address here Tick the Ignore the wizard next time option to skip the Smart Wizard on the next login Click the Exit button to discard the changes made exit the Smart Wizard and continue to the Standard Mode Web UI Click the Next button to accept the changes made and continue to the next step Step 3 Admin Password In this window the user can s...

Страница 25: ...ue to the Web UI NOTE Standard Mode and Surveillance Mode Web UIs share the same configuration files Any features enabled in one interface will be made available in the other interface for example PoE scheduling SNMP settings and the surveillance VLAN in use NOTE Settings are saved between interface types It is possible to switch interface types and re run the Smart Wizard without losing settings ...

Страница 26: ...anual 22 Web User Interface When you complete the Surveillance Mode Smart Wizard you will be presented with the following screen Figure 4 5 Congratulations window Scroll to the bottom of the page and click the OK button to continue to the Web UI ...

Страница 27: ...n the table Figure 4 6 Main Web UI Window Area Number Description AREA 1 The navigation menu is displayed in this area Click on the links and navigate the folder structure to display information on the main page AREA 2 This is the main page for displaying information and configuration options for the switch The page displayed here is based on the selection in AREA 1 AREA 1 AREA 2 ...

Страница 28: ... Switch Model Number Surveillance Topology This is the default tab on the Surveillance Overview page It contains a diagram of the surveillance topology including an overview of the devices connected to the switch To view the following window click on the model number of the switch at the top of the navigation menu Figure 5 2 Surveillance Topology Window There is a device count at the top of the pa...

Страница 29: ... link to get more information about the devices connected to a port Each port can also be powered on and off using PoE by clicking the power symbol on each port CAUTION Before connecting the Powered Device PD and enabling 60 70 W PoE make sure it supports IEEE 802 3bt as otherwise it will become damaged See below for more information on enabling and disabling PoE A breakdown of each device icon is...

Страница 30: ...onds The icon border indicates the PoE status for the port Icon Border Description The device is operational but not powered by PoE The device is operational and is powered by PoE The device has malfunctioned and there is a problem with the port or device The port status indicators dictate the speed and status of the link Port Status Description The link is down The port is connected at 1 Gbps The...

Страница 31: ...of each port can be changed by clicking the power icon on each port The default setting for PoE is on To change the PoE type first disable PoE and then re enable it using the type of PoE required The following dialogue box will be displayed when enabling PoE on a port Figure 5 3 PoE Configuration Choose the type of PoE required This can be either 15 30 W 60 W or 75 W is for MPP Series only Click t...

Страница 32: ...such as the device type system name serial number IP address settings MAC address settings firmware versions and system uptime The PoE utilization area contains PoE utilization statistics for the switch On the left is the total PoE utilization with the total power budget and overall utilization shown On the right is a per port usage graph showing the PoE utilization for each individual port The ba...

Страница 33: ...e Port Information link in the navigation menu Figure 6 1 Port Information Window A breakdown of the devices connected the number of ports in use and the total throughput is listed at the top of the page The icon descriptions are as follows Icon Description The total amount of ports that are currently active The total inbound throughput for all ports on the switch The total number of ONVIF IP Came...

Страница 34: ...he port This is listed as one negative integer and one positive integer A negative value for PoE means that power is being consumed by the port The positive integer is the PoE budget for PoE standard in use The Loopback Detection status If a loop is detected the icon will change to include a link to the Health Diagnostics page The Group Details page If an ONVIF device is detected as being connecte...

Страница 35: ...criptions are as follows Icon Description The port number that the Group Details apply to Click to go back to the Port Information page Hover over each field to get more information about each value A breakdown of each field is below Icon Description The Group Number that the device belongs to All devices managed by an NVR belong to the same Group Number These are assigned sequentially with NVR1 h...

Страница 36: ...D Link DGS 1100 MP MPP Series Switch User Manual 32 The device description This can be edited on the IP Camera Information page or NVR Information page ...

Страница 37: ...riptions are as follows Icon Description The total number of ONVIF IP Cameras detected The total inbound throughput for all ports on the switch The PoE consumption of the switch This is listed as one negative integer and one positive integer The negative integer is the power being consumed by the PoE devices connected to the switch The positive integer is the total PoE budget for the ports current...

Страница 38: ...r and one positive integer A negative value for PoE means that power is being consumed by the port The positive integer is the PoE budget for PoE standard in use The IP address of the IP Camera The location of the IP Camera The description of the IP Camera This can be edited by clicking the black pencil icon next to the field and then the green pencil icon when the description has been entered ...

Страница 39: ... listed at the top of the page The icon descriptions are as follows Icon Description The total number of NVRs detected The total inbound throughput for all ports on the switch Hover over each field to get more information about each value A breakdown of each field is below Icon Description The port number of the port The device icon or photo A generic photo is displayed for all NVR types The total...

Страница 40: ...Number 1 If an NVR is removed the Group Numbers will be updated accordingly if NVR1 is removed then Group Number 2 will become Group Number 1 The number of ONVIF IP Cameras managed by this NVR Information relating to an IP Camera in the group such as port number and IP address ...

Страница 41: ...E Information Window The total power budget power consumption power budget consumption and the types of PoE in use are listed at the top of the page The icon descriptions are as follows Icon Description The total PoE power budget The PoE consumption of the switch This is listed as one negative integer and one positive integer The negative integer is the power being consumed by the PoE devices conn...

Страница 42: ...wer budget for this port This can be 30 W or 30W 60W 75W if this port supports 4 pair PoE The PoE state If any fault is detected the icon changes to include a description of the problem and a link to the Health Diagnostic page The PoE consumption of the port This is listed as one negative integer and one positive integer A negative value for PoE means that power is being consumed by the port The p...

Страница 43: ...nfigured for the Time Profile are described below Parameter Description Range Name Enter a descriptive name for the PoE schedule Daily Check this tick box to enable the schedule daily and gray out the day of week fields in the From Time To Time sections From Time Day Hour The start day and time for the PoE schedule Click the calendar icon to pick this using a graphic calendar tool To Time Day Hour...

Страница 44: ...D Link DGS 1100 MP MPP Series Switch User Manual 40 Time Profile The Time Profile created above Click the Apply button to accept the changes made ...

Страница 45: ...Date DD MM YYYY Use this to set the date in the format DD MM YYYY Click the Apply button to accept the changes made SNTP Settings This sub menu is used to configure an external time source on the switch Simple Network Time Protocol SNTP is a lightweight version of the NTP protocol and can be used to keep the system clock in sync by using a network based time source To view the following window go ...

Страница 46: ...rval for SNTP The default is 720 seconds and the range is 30 99999 seconds Click the Apply button to accept the changes made The fields that can be configured for the SNTP Server Setting are described below Parameter Description IPv4 Address Enter the IP address of the SNTP server you would like to synchronize with Click the Apply button to accept the changes made ...

Страница 47: ... Settings are described below Parameter Description VLAN ID 2 4094 Enter a VLAN number for the surveillance VLAN in the range 2 4094 Click the Apply button to accept the changes made The fields that can be configured for the IP Settings are described below Parameter Description Get IP From Choose how the management IP for this VLAN is assigned to the switch Options are DHCP Static or BOOTP If Stat...

Страница 48: ...below Parameter Description Password Configure the password that will be used to restrict access to the device via the Web UI Password length is a maximum of 20 characters Confirm Password Confirm the password that will be used to restrict access to the device via the Web UI Password length is a maximum of 20 characters Click the Apply button to accept the changes made The fields that can be confi...

Страница 49: ...ther switches as the IP Camera discovery process is disabled on these ports Use the Uplink Port Settings section of the interface to define which ports connect to other switches NOTE The default uplink ports of the DGS 1100 10MP 10MPP are port9 and port10 The default uplink ports of DGS 1100 26MP 26MPP are port25 and port26 ...

Страница 50: ...gging server The messages are ordered in date order with the latest message at the top of the list Please consult an external source for more information on Syslog logging levels To view the following window click on the Surveillance Log link in the navigation menu Figure 13 1 Surveillance Log Window Refresh This will refresh the page Backup This will allow you to save a local copy of the Syslog m...

Страница 51: ...on status Cable Link status PoE Status Tx Rx Error Counter number of Discovered Surveillance Devices on the port which links to the Group Details page and the detected cable length The page automatically refreshes every 30 seconds To view the following window click on the Health Diagnostic link in the navigation menu Figure 14 1 Health Diagnostic Window Detect Detect the cable length of the listed...

Страница 52: ...ected firmware make sure that the switch is rebooted Firmware Upgrade Backup NOTE When upgrading the firmware on the DGS 1100 MP MPP Series switch only the image not currently active can be upgraded All DGS 1100 MP MPP Series switches come with two images however only one can be active at any time e g If image 1 is currently in use only image 2 can be upgraded and vice versa NOTE If the switch is ...

Страница 53: ... Upgrade button to initiate the firmware upgrade Firmware Backup to HTTP This window is used to initiate a firmware backup to a local PC using HTTP To view the following window click Tools Firmware Upgrade Backup Firmware Backup to HTTP as shown below Figure 15 3 Firmware Backup to HTTP window The fields that can be configured are described below Parameter Description Source Select the source imag...

Страница 54: ...vigate to the location of the configuration file located on the local PC Click the Restore button to initiate the configuration restore Click Effective immediately running config to have the uploaded configuration loaded immediately Click Take effect after the next boot startup config to load the configuration after the switch has been rebooted Configuration Backup to HTTP This window is used to i...

Страница 55: ...nged Select the The Switch will be reset to its factory defaults including IP address option to reset the switch s configuration to its factory default settings Click the Apply button to initiate the factory default reset and reboot the switch NOTE Performing a factory reset in one version of the interface Standard Mode or Surveillance Mode will cause settings to be reset in the other version of t...

Страница 56: ...D Link DGS 1100 MP MPP Series Switch User Manual 52 Figure 15 8 Reboot System Rebooting window ...

Страница 57: ...y improving switching and routing internetworking technologies And with expected advances in the coming years in silicon technology and digital signal processing that will enable Gigabit Ethernet to eventually operate over unshielded twisted pair UTP cabling outfitting your network with a powerful 1000 Mbps capable backbone server connection which will create a flexible foundation for the next gen...

Страница 58: ...n capacity The switch acts as a high speed selective bridge between the individual segments The switch without interfering with any other segments automatically forwards traffic that needs to go from one segment to another By doing this the total network capacity is multiplied while still maintaining the same network cabling and adapter cards ...

Страница 59: ...ll half Duplex operations at 10 100Mbps Supports Full Duplex operation at 1000Mbps Supports IEEE 802 3x Flow Control Support Auto Negotiation Compliant to IEEE 802 3az Energy Efficiency Ethernet SFP ports compliant with the following standards IEEE 802 3z compliance Physical Environment Power input 100 240 VAC 50 60Hz internal universal power supply Acoustic Value DGS 1100 10MP 45 4dB DGS 1100 10M...

Страница 60: ...ration backup restoration via Web based management Firmware backup upgrade via Web based management Reset Reboot system Factory reset by pressing reset button SNMP LLDP Dual Image 2 level user account SNTP Power Saving IEEE 802 3az Compliant Energy Efficient Ethernet D Link Green Technologies Power saving by link status Power Saving by LED Shut Off Power Saving by Port Shut Off Power Saving by Sys...

Страница 61: ...e equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised C Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading D Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effe...

Страница 62: ...D Link DGS 1100 Series Switch User Manual ...

Отзывы: