Hardware Installation 

Before You Begin

Observe the following precautions to help prevent 

shutdowns, equipment failures, and personal injury:
•  Install the DGS-1010MP in a cool and dry 

place. Refer to the technical specifications in 

the user manual for the acceptable operating 

temperature and humidity ranges.

•  Install the switch in a site free from strong 

electromagnetic sources, vibration, dust, and 

direct sunlight.

•  Leave at least 10 cm of space to the left and right-

hand side of the switch for ventilation.

•  Visually inspect the power connector and make 

sure that it is fully secured to the power cord.

•  Do not stack any devices on top of the switch.

Using the Switch on a Flat Surface

The included rubber pads can be placed on the 

bottom of the device to prevent it from damaging 

the surface it is placed on.
1.  Remove the rubber pads from the adhesive strip.

2.  Stick one pad on each corner on the bottom 

panel of the switch.

Figure 4

Mounting the Switch in a Rack

The DGS-1010MP can be mounted into a standard 

19” server rack. 
1.  Attach the included mounting brackets to the 

sides of the switch and secure them using the 

provided screws.

Figure 5

2.  Install the switch into the rack.
3.  Use the screws that were provided with the rack 

to secure the switch to the rack.

Figure 6

Grounding the Switch

This step must be completed before powering on 

the switch.

Required tools and equipment for grounding

•  Grounding screw (included) and one M4x6 

(metric) pan-head screw (not included).

•  Grounding cable (not included). The grounding 

cable should be sized according to local and 

national installation requirements. Depending 

on the power supply and system, a 12 to 6 AWG 

copper conductor is required for installation. 

Commercially available 6 AWG wire is 

recommended. The length of the cable depends 

on the proximity of the switch to proper 

grounding facilities.

•  A screwdriver (not included).

Note: 

Verify that the system is powered off.

1.  Remove the grounding screw from the back of 

the device and place the #8 terminal lug ring of 

the grounding cable on top of the grounding 

screw opening.

2.  Insert the grounding screw back into the screw 

opening and use a screwdriver to tighten the 

grounding screw.

Содержание DGS-1010MP

Страница 1: ... Unmanaged Gigabit PoE Switch Неуправляемый коммутатор с 9 портами 10 100 1000Base T 1 портом 1000Base X SFP функцией энергосбережения и поддержкой QoS 8 портов с поддержкой PoE 802 3af at 30 Вт PoE бюджет 125 Вт Краткое руководство по установке ...

Страница 2: ... Slot This is used for securing the power cord retainer to the switch 3 Switch GND This is used to connect the switch to ground 4 Kensington Lock Input This is used to attach a Kensington security lock Table 3 Before You Begin This Quick Installation Guide gives you step by step instructions for setting up your DGS 1010MP 10 Port Unmanaged Gigabit PoE Switch The model you have purchased may appear...

Страница 3: ...ed into a standard 19 server rack 1 Attach the included mounting brackets to the sides of the switch and secure them using the provided screws Figure 5 2 Install the switch into the rack 3 Use the screws that were provided with the rack to secure the switch to the rack Figure 6 Grounding the Switch This step must be completed before powering on the switch Required tools and equipment for grounding...

Страница 4: ...acingup insertthetieinto the opening below the power socket Figure 7 2 Plug the power cord into the power socket on the switch Figure 8 3 Slide the retainer through the tie until it has reached the end of the power cord Figure 9 4 Wrap the tie of the retainer strip around the power cord and back into the retainer to lock it Fasten the tie until the power cord is secured Figure 10 Connecting to the...

Страница 5: ... SFP uplink ports Switch to Server Connect the switch to a network backbone or network server using the RJ 45 or SFP uplink ports Additional Information For additional support please refer to the user manual or visit http support dlink com which will direct you to your local D Link support website ...

Страница 6: ...вовать параметрам электропитания указанным в технических характеристиках устройства Не вскрывайте корпус устройства Перед очисткой устройства от загрязнений и пыли отключите питание устройства Удаляйте пыль с помощью влажной салфетки Не используйте жидкие аэрозольные очистители или магнитные статические устройства для очистки Избегайте попадания влаги в устройство Устройство должно быть заземлено ...

Страница 7: ...блица 2 Компоненты задней панели 1 2 3 4 Рисунок 3 Компонент Описание 1 Разъем питания Разъем предназначен для подключения кабеля питания Перед началом работы Данное руководство содержит инструкции по установке неуправляемого коммутатора DGS 1010MP Помните что приобретенная Вами модель может незначительно отличаться от изображенной в руководстве Комплект поставки КомплектпоставкиDGS 1010MPдолженсо...

Страница 8: ... комплект поставки DGS 1010MP входят резиновые ножки которые помогают защитить корпус коммутатора и поверхность на которую он устанавливается от царапин 1 Снимите липкую ленту с резиновых ножек 2 Прикрепите резиновые ножки к нижней панели коммутатора расположив их по углам Рисунок 4 Установка коммутатора в стойку Коммутатор DGS 1010MP может быть установлен в 19 дюймовую стойку 1 Прикрепите входящи...

Страница 9: ...разъемом питания Рисунок 7 2 Подключите кабель питания к коммутатору Рисунок 8 3 Наденьте зажим на стяжку и сместите его в сторону разъема питания Рисунок 9 4 Оберните ленту зажима вокруг кабеля питания и вставьте ее в фиксирующий замок Затяните ленту зажима для надежной фиксации кабеля питания Рисунок 10 Подключение коммутатора к сети Коммутатор можно подключить к сети одним из следующих способов...

Страница 10: ... к концентратору или другому коммутатору Подключение коммутатора к магистрали сети или серверу Uplink порт SFP или 10 100 1000Base T может использоваться для подключения коммутатора к магистрали сети или серверу Дополнительная информация Для получения дополнительной информации обратитесь к руководству пользователя или посетите Web сайт http www dlink ru ...

Страница 11: ...t 2000 Мбит с полный дуплекс Производительность Коммутационная матрица 20 Гбит с Метод коммутации Store and forward Макс скорость перенаправления 64 байтных пакетов 14 88 Mpps Размер таблицы МАС адресов 4K записей Буфер пакетов 192 КБ PoE Стандарт PoE IEEE 802 3af IEEE 802 3at Порты с поддержкой PoE Порты 1 8 Бюджет мощности PoE 125 Вт макс 30 Вт на порт PoE Физические параметры Размеры Д x Ш x В ...

Страница 12: ...р ООО Д Линк Трейд 390043 г Рязань пр Шабулина д 16 Тел 7 4912 503 505 Россия Москва Графский переулок 14 Тел 7 495 744 00 99 E mail mail dlink ru Україна Київ вул Межигірська 87 А Тел 38 044 545 64 40 E mail ua dlink ua Moldova Chisinau str C Negruzzi 8 Tel 373 22 80 81 07 E mail info dlink md Беларусь Мінск пр т Незалежнасці 169 Тэл 375 17 218 13 65 E mail support dlink by Қазақстан Алматы Құрма...

Отзывы: