background image

 

    

24

 

 

Registration Card ( Excluding USA) 

 

 

Print, type or use block letters. 

Your name: Mr./Ms______________________________________________________________________ 
Organization: ________________________________________Dept.______________________________ 
Your title at organization:_________________         Telephone:_____________________ Fax:___________ 
Organization's full address:_______________________________________________________________ 
Country:______________________________________________________________________________ 
Date of purchase (Month/Day/Year):_________________________________________________________

 

Product 

Model 

Product Serial No. 

* Product installed in type of 

computer (e.g., Compaq 486) 

* Product installed in computer 

serial No. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(* Applies to adapters only) 

Product was purchased from: 

Reseller's name:________________________________________________________________________ 
Telephone:________________________________ Fax:_________________________________________ 
Reseller's full address:___________________________________________________________________ 
______________________________________________________________________________________ 

Answers to the following questions help us to support your product: 

1. Where and how will the product primarily be used? 

 

Home  Office  Travel  Company Business  Home Business  Personal Use 

2. How many employees work at installation site? 

 

1 employee  2-9  10-49  50-99  100-499  500-999  1000 or more 

3. What network protocol(s) does your organization use ? 

 

XNS/IPX  TCP/IP  DECnet  Others_____________________________________________________ 

4. What network operating system(s) does your organization use ? 

 

D-Link LANsmart  Novell NetWare  NetWare Lite  SCO Unix/Xenix  PC NFS  3Com 3+Open 

 

Banyan Vines  DECnet Pathwork  Windows NT  Windows 2000  Windows XP 

 

Others_____________________________________________________________________________ 

5. What network management program does your organization use ? 

 

D-View  HP OpenView/Windows  HP OpenView/Unix  SunNet Manager  Novell NMS 

 

NetView 6000  Others_________________________________________________________________ 

6. What network medium/media does your organization use ? 

 

Fiber-optics  Thick coax Ethernet  Thin coax Ethernet  10BASE-T UTP/STP 

 

100BASE-TX  100BASE-T4  100VGAnyLAN  Others________________________________________ 

7. What applications are used on your network? 

 

Desktop publishing  Spreadsheet  Word processing  CAD/CAM  Database management  Accounting 

Others____________________________________________________________________ 

8. What category best describes your company? 

 

Aerospace  Engineering  Education  Finance  Hospital  Legal  Insurance/Real Estate  Manufacturing 

Retail/Chainstore/Wholesale  Government  Transportation/Utilities/Communication  VAR  System 

house/company  Other_____________________________________________________ 

9. Would you recommend your D-Link product to a friend? 

 

Yes  No  Don't know yet 

10.Your comments on this product? _____________________________________________________ 

_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
___________________________________

 

 

Содержание DGS-1008D - Switch

Страница 1: ...D Link DGS 1008D 8 Port 10 100 1000Mbps Gigabit Ethernet Switch Manual Rev 2 01 Building Networks for People RECYCLABLE ...

Страница 2: ...adiate radio frequency energy and if not installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class B product In a domestic environment thi...

Страница 3: ...AR PANEL DESCRIPTION 5 INSTALLATION 6 Package Contents 6 BEFORE YOU CONNECT TO THE NETWORK 6 MOUNTING THE SWITCH ON A WALL 7 ATTACHING THE RUBBER FEET 7 PROVIDE FOR ADEQUATE VENTILATION 8 POWER ON 8 Power Failure 8 CONNECTING THE SWITCH 9 SWITCH TO END NODE 9 SWITCH TO HUB OR SWITCH 10 CONNECTING TO NETWORK BACKBONE OR SERVER 10 TECHNICAL SPECIFICATIONS 11 GLOSSARY 12 WARRANTY AND REGISTRATION INF...

Страница 4: ...ub switch or backbone server Appendix A Technical Specifications The technical specifications of the DGS 1008D Glossary Lists definitions for terms and acronyms used in this document Index Index of relevant terms in the DGS 1008D User s Guide Intended Readers The DGS 1008D User s Guide contains information for setup and management and of the DGS 1008D switch This guide is intended for network mana...

Страница 5: ...en you follow the operating instructions Keep your system away from radiators and heat sources Also do not block cooling vents Do not spill food or liquids on your system components and never operate the product in a wet environment If the system gets wet see the appropriate section in your troubleshooting guide or contact your trained service provider Do not push any objects into the openings of ...

Страница 6: ...ollow your local national wiring rules When connecting or disconnecting power to hot pluggable power supplies if offered with your system observe the following guidelines Install the power supply before connecting the power cable to the power supply Unplug the power cable before removing the power supply If the system has multiple sources of power disconnect power from the system by unplugging all...

Страница 7: ...take the following steps to prevent damage from electrostatic discharge ESD 1 When unpacking a static sensitive component from its shipping carton do not remove the component from the antistatic packing material until you are ready to install the component in your system Just before unwrapping the antistatic packaging be sure to discharge static electricity from your body 2 When transporting a sen...

Страница 8: ...necks that frequently develop as computers and their busses get faster and more users use applications that generate more traffic Upgrading key components such as your backbone and servers to Gigabit Ethernet can greatly improve network response times as well as significantly speed up the traffic between your subnetworks Gigabit Ethernet enables fast optical fiber connections to support video conf...

Страница 9: ...ch Description The DGS 1008D Switch module is equipped with eight ports providing dedicated 10 100 or 1000 Mbps bandwidth These ports can be used for connecting PCs servers and hubs The eight multi speed ports use standard twisted pair cabling and are ideal for segmenting networks into small connected subnets Each port can support up to 2000 Mbps of throughput in full duplex mode This stand alone ...

Страница 10: ...tting or receiving data on the network Speed 100Mbps amber 1000Mbps green 10Mbps off This indicator is amber colored when the port is connected to a 100Mbps Fast Ethernet station It is green when the port is connected to a 1000Mbps Ethernet station It is not illuminated when the port is connected to a 10Mbps Ethernet station Cable Diagnostic LED Indications When the Switch is booted the Cable Diag...

Страница 11: ... after the initial port scan The Switch is then reset for normal operation It takes about 2 seconds for the Switch to reset The entire Cable Diagnostic process takes about 17 seconds from the time the Switch is booted So from the time power is first applied to the Switch about 17 seconds is required before the Switch will begin normal operation There is no display of cable faults detected by the C...

Страница 12: ...nal AC power adapter Check the technical specification section for information about the AC power input voltage Figure 1 2 Rear panel view of the Switch 1000BASE T Ports Eight 8 Gigabit Ethernet Auto Negotiating ports 10 100 1000Mbps Comprehensive LED indicators display the conditions of the Switch and status of the network ...

Страница 13: ...nstall the Switch on a sturdy level surface that can support at least 3 kg of weight Do not place heavy objects on the Switch The power outlet should be within 1 82 meters 6 feet of the Switch Visually inspect the power cord and see that it is fully secured to the AC power port Make sure that there is proper heat dissipation from and adequate ventilation around the switch Leave at least 10 cm of s...

Страница 14: ...nt wall 2 Drive the T3 x 15L screws into the Nylon screw anchors 3 Hook the mounting holes of the switch back on the screws you have completed the wall mount B Mounting on a wood wall 1 Drive the T3 x 15 L screws into the wood wall 2 Hook the mounting holes of the switch back on the screws you have completed the wall mount Figure 2 1 Mounting the Switch to a Wall Attaching the Rubber Feet Use rubb...

Страница 15: ...in the event of a power failure unplug the Switch When power is resumed plug the Switch back in CAUTION Do not place any device on top of Switch or place the Switch on top of any device or object that will block the free flow of air through the ventilation slots on the sides top and bottom of the Switch s case In addition care should be taken not to locate the Switch next to on top of or underneat...

Страница 16: ...node can be connected to the Switch via a twisted pair Category 3 4 or 5 UTP STP cable The end node can be connected to any of the ports of the Switch Figure 3 1 Switch connected to an end node The Link Act LEDs for each UTP port light green when the link is valid The LED over the port label indicates a port speed of either 10 100 Mbps or 1000Mbps A blinking LED on the bottom indicates packet acti...

Страница 17: ... to the Switch via a twisted pair Category 5 UTP STP cable A 1000BASE T switch can be connected to the Switch via a twisted pair Category 5e UTP STP cable Figure 3 2 Switch connected to a port on a hub or switch using either a straight or crossover cable any normal cable is fine Connecting To Network Backbone or Server Any of the eight Gigabit Ethernet ports are ideal for uplinking to a network ba...

Страница 18: ...nshield Twisted Pair UTP Cable Gigabit Ethernet 4 pair UTP Cat 5e Unshield Twisted Pair UTP Cable Number of Ports Eight 8 10 100 1000BASE T Gigabit Ethernet ports Physical and Environmental DC Inputs 5V 3A Power Consumption 11 watts maximum Operating Temperature 32 F 131F 0 C 55 Storage Temperature 14 F 158 F 10 C 70 C Humidity 5 95 RH non condensing Dimensions 9 25 in x 6 37 in x 1 4 in 235mm x 1...

Страница 19: ...s started In addition the protocol can assign the subnet mask and default gateway to a device bridge A device that interconnects local or remote networks no matter what higher level protocols are involved Bridges form a single logical network centralizing network administration broadcast A message sent to all destination devices on the network broadcast storm Multiple simultaneous broadcasts that ...

Страница 20: ...pabilities by addressing up to ten different groups of information RPS Redundant Power System A device that provides a backup source of power when connected to the Switch server farm A cluster of servers in a centralized location serving a large user population SLIP Serial Line Internet Protocol A protocol which allows IP to run over a serial line connection SNMP Simple Network Management Protocol...

Страница 21: ...ed Gigabit Ethernet Switch 14 VLT Virtual LAN Trunk A Switch to Switch link which carries traffic for all the VLANs on each Switch VT100 A type of terminal which uses ASCII characters VT100 screens have a text based appearance ...

Страница 22: ...in its documentation D Link further warrants that during the Warranty Period the magnetic media on which D Link delivers the Software will be free of physical defects D Link s sole obligation shall be to replace the non conforming Software or defective media with software that substantially conforms to D Link s functional specifications for the Software or to refund at D Link s sole discretion Exc...

Страница 23: ...mer of Other Warranties EXCEPT FOR THE LIMITED WARRANTY SPECIFIED HEREIN THE PRODUCT IS PROVIDED AS IS WITHOUT ANY WARRANTY OF ANY KIND WHATSOEVER INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NON INFRINGEMENT IF ANY IMPLIED WARRANTY CANNOT BE DISCLAIMED IN ANY TERRITORY WHERE A PRODUCT IS SOLD THE DURATION OF SUCH IMPLIED WARRANTY SHALL BE LIMIT...

Страница 24: ...e pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communication However there is no guarantee that interference will n...

Страница 25: ...lfe dieser Anleitung keine Verbesserung erzielen e Das Gerät ist gefallen und oder das Gehäuse ist beschädigt f Wenn das Gerät deutliche Anzeichen eines Defektes aufweist 16 Bei Reparaturen dürfen nur Orginalersatzteile bzw den Orginalteilen entsprechende Teile verwendet werden Der Einsatz von ungeeigneten Ersatzteilen kann eine weitere Beschädigung hervorrufen 17 Wenden Sie sich mit allen Fragen ...

Страница 26: ...Any package returned to D Link without an RMA number will be rejected and shipped back to Purchaser at Purchaser s expense and D Link reserves the right in such a case to levy a reasonable handling charge in addition mailing or shipping costs Software Warranty service for software products may be obtained by contacting a D Link office within the applicable warranty period A list of D Link offices ...

Страница 27: ...iqiao Road Haidan District 100081 Beijing China TEL 86 10 68467106 FAX 86 10 68467110 URL www dlink com cn E MAIL liweii digitalchina com cn Denmark D Link Denmark Naverland Denmark Naverland 2 DK 2600 Glostrup Copenhagen Denmark TEL 45 43 969040 FAX 45 43 424347 URL www dlink dk E MAIL info dlink dk Egypt D Link Middle East 7 Assem Ebn Sabet Street Heliopolis Cairo Egypt TEL 202 245 6176 FAX 202 ...

Страница 28: ...492 FAX 7 095 737 3390 URL www dlink ru E MAIL vl dlink ru Singapore D Link International 0 1 International Business Park 03 12 The Synergy Singapore 609917 TEL 6 6774 6233 FAX 6 6774 6322 E MAIL info dlink com sg URL www dlink intl com South Africa D Link South Africa Unit 2 Parkside 86 Oak Avenue Highveld Technopark Centurion Gauteng South Africa TEL 27 12 665 2165 FAX 27 12 665 2186 URL www d l...

Страница 29: ...8731 5555 SALES 44 020 8731 5550 FAX 44 020 8731 5511 SALES 44 020 8731 5551 BBS 44 0 181 235 5511 URL www dlink co uk E MAIL info dlink co uk U S A D Link U S A 17395 Mt Herrmann Fountain Valley CA 92708 4160 TEL 1 949 788 0805 FAX 1 949 753 7033 INFO 1 800 326 1688 URL www dlink com E MAIL tech dlink com support dlink com tw ...

Страница 30: ...23 ...

Страница 31: ...__________________ 4 What network operating system s does your organization use D Link LANsmart Novell NetWare NetWare Lite SCO Unix Xenix PC NFS 3Com 3 Open Banyan Vines DECnet Pathwork Windows NT Windows 2000 Windows XP Others_____________________________________________________________________________ 5 What network management program does your organization use D View HP OpenView Windows HP Ope...

Страница 32: ...25 ...

Отзывы: