![D-Link DES-3250TG Скачать руководство пользователя страница 142](http://html1.mh-extra.com/html/d-link/des-3250tg/des-3250tg_user-manual_3331186142.webp)
D-Link DES-3250TG Standalone Layer 2 Switch
Figure 9- 10. Rx Error Analysis window (table)
The following fields can be set:
Parameter
Description
Time Interval [
1s
]
Select the desired setting between
1s
and
60s
,
where “s” stands for seconds. The default
value is one second.
Record Number [
200
]
Select number of times the Switch will be
polled between
20
and
200
. The default value
is
20.
CrcError
Counts otherwise valid frames that did not
end on a byte (octet) boundary.
UnderSize
The number of frames detected that are less
than the minimum permitted frame size of 64
bytes and have a good CRC. Undersize
frames usually indicate collision fragments, a
normal network occurrence.
OverSize
Counts packets received that were longer
than 1518 octets, or if a VLAN frame 1522
octets, and less than the MAX_PKT_LEN.
Internally, MAX_PKT_LEN is equal to
1522.
Fragment
The number of packets less than 64 bytes
with either bad framing or an invalid CRC.
These are normally the result of collisions.