background image

DES-3010F/DES-3010FL/DES-3010G/DES-3018/DES-3026 Fast Ethernet Switch Manual 

IP Address Assignment 

Each Switch must be assigned its own IP Address, which is used for communication with an SNMP network manager or 
other TCP/IP application (for example BOOTP, TFTP). The Switch's default IP address is 10.90.90.90. You can change 
the default Switch IP address to meet the specification of your networking address scheme. 

The Switch is also assigned a unique MAC address by the factory. This MAC address cannot be changed, and can be found 
by entering the command "

show switch

" into the command line interface, as shown below.  

 

Figure 4- 4.  “show switch” command 

The Switch's MAC address can also be found from the Web management program on the 

DES-3018 Web Management 

Tool

The IP address for the Switch must be set before it can be managed with the Web-based manager. The Switch IP address 
can be automatically set using BOOTP or DHCP protocols, in which case the actual address assigned to the Switch must be 
known. 

The IP address may be set using the Command Line Interface (CLI) over the console serial port as follows: 

Starting at the command line prompt, enter the commands 

config ipif System ipaddress 

xxx.xxx.xxx.xxx/yyy.yyy.yyy.yyy.

 Where the x's represent the IP address to be assigned to the IP interface named System 

and the y's represent the corresponding subnet mask. 

Alternatively, you can enter 

config ipif System ipaddress xxx.xxx.xxx.xxx/z. 

Where the x's represent the IP address to be 

assigned to the IP interface named System and the z represents the corresponding number of subnets in CIDR notation. 

The IP interface named System on the Switch can be assigned an IP address and subnet mask, which can then be used to 
connect a management station to the Switch's Telnet or Web-based management agent. 

 

21

Содержание DES-3010F

Страница 1: ...D Link DES 3010F DES 3010FL DES 3010G DES 3018 DES 3026 Managed 8 16 24 Port 10 100Mbps Fast Ethernet Switch with Optional Slots Release III Manual...

Страница 2: ...ration is strictly forbidden Trademarks used in this text D Link and the D LINK logo are trademarks of D Link Computer Corporation Microsoft and Windows are registered trademarks of Microsoft Corporat...

Страница 3: ...anel Description 6 Installation 7 Package Contents 7 Before You Connect to the Network 7 Installing the Switch without the Rack 8 Installing the Switch in a Rack 8 Mounting the Switch in a Standard 19...

Страница 4: ...rface 30 Port Configurations 31 Port Description 33 Port Err Disabled 34 User Accounts 35 Admin and User Privileges 36 Port Mirroring 37 System Log Settings 38 SNTP Settings 40 Time Setting 40 Time Zo...

Страница 5: ...tering 69 Unicast Forwarding 69 Multicast Forwarding 70 Multicast Filtering 71 SMTP Service 72 SMTP Server Settings 73 SMTP Service 74 L2 Features 75 VLANs 75 VLAN Description 75 Notes about VLANs on...

Страница 6: ...Port Mapping Priority CoS 102 MAC Priority Setting 102 CPU Interface Filtering 103 CPU Interface Filtering State Settings 103 CPU Interface Filtering Table 103 Security 114 Traffic Control 114 Port S...

Страница 7: ...eceived RX 143 Transmitted TX 145 Packet Size 147 MAC Address 148 Switch History Log 150 Log Settings 151 IGMP Snooping Group 152 Browse Router Port 153 Browse ARP Table 153 Session Table 153 Port Acc...

Страница 8: ...Warranties and Registration 173 Technical Support 184 International Offices 210...

Страница 9: ...of the Switch including accessing the Switch information using the Switch s utilities and setting up network configurations such as assigning an IP address Port Configurations User Accounts Port Mirr...

Страница 10: ...and commands For example use the copy command Boldface Typewriter Font Indicates commands and responses to prompts that must be typed exactly as printed in the manual Initial capital letter Indicates...

Страница 11: ...in a wet environment If the system gets wet see the appropriate section in your troubleshooting guide or contact your trained service provider Do not push any objects into the openings of your system...

Страница 12: ...h care ensure that all casters and or stabilizers are firmly connected to the system Avoid sudden stops and uneven surfaces General Precautions for Rack Mountable Products Observe the following precau...

Страница 13: ...s are connected Completed power and safety ground wiring must be inspected by a qualified electrical inspector An energy hazard will exist if the safety ground cable is omitted or disconnected Protect...

Страница 14: ...switch Comprising 10 100Mbps switched unshielded twisted pair UTP and Auto MDI X MDI II convertible ports and each model having its own uplink port capability this Switch will be ideal for segmenting...

Страница 15: ...ort port based enable and disable Address table Supports up to 8K MAC addresses per device Port Trunking with flexible load distribution and fail over function IGMP Snooping support SNMP support SMTP...

Страница 16: ...enal bandwidth delivered by Gigabit Ethernet is the most cost effective method to take advantage of today s and tomorrow s rapidly improving switching and routing internetworking technologies Switchin...

Страница 17: ...Speed 8 16 24 Fast Ethernet ports two optional module ports DES 3018 3026 only a gigabit 1000BASE T copper port DES 3010F G a 100BASE FX Ethernet port DES 3010F DES 3010FL and a SFP Gigabit Ethernet...

Страница 18: ...a valid link A blinking LED indicates activity on the port Speed To the right of every Link Act LED lies the speed LED corresponding to every port Depending on the switch model these lights will assu...

Страница 19: ...G and DES 3018 DES 3026 Side Panel Description Both panels of the Switch contain a heat vent used to dissipate heat Do not block these openings and leave at least 6 inches of space at the rear and sid...

Страница 20: ...he Switch may greatly affect its performance Please follow these guidelines for setting up the Switch Install the Switch on a sturdy level surface that can support the weight of the Switch Do not plac...

Страница 21: ...following diagrams to guide you Figure 2 2 Fasten mounting brackets to Switch Fasten the mounting brackets to the Switch using the screws provided With the brackets attached securely you can mount the...

Страница 22: ...EDs for Speed Link and Act ivity Supports auto negotiation in 10 100 1000M full duplex back pressure in half duplex and IEEE802 3x compliant flow control for full duplex Single Port SFP gigabit uplink...

Страница 23: ...o the individual but to the Switch as well At the front of the Switch to the right is the slot for the optional module as shown in Figure 2 7 and Figure 2 8 This slot should be covered with a faceplat...

Страница 24: ...DES 3010F DES 3010FL DES 3010G DES 3018 DES 3026 Fast Ethernet Switch Manual Figure 2 10 Inserting the optional module into the Switch The upgraded DES 3018 DES 3026 is now ready for use 11...

Страница 25: ...ons Switch to End Node End nodes include PCs outfitted with a 10 100 or 1000 Mbps RJ 45 Ethernet Network Interface Card NIC and most routers An end node can be connected to the Switch via a twisted pa...

Страница 26: ...STP cable A 100BASE TX hub or switch can be connected to the Switch via a twisted pair Category 5 UTP STP cable A 1000BASE T switch can be connected to the Switch via a twisted pair Category 5e UTP S...

Страница 27: ...s are endless but be sure that connections coming from the DES 3018 are at a equal or slower speed than the ISP uplink to avoid bottlenecking The copper ports operate at a speed of 100Mbps or 10Mbps i...

Страница 28: ...ersion 5 0 SNMP Based Management You can manage the Switch with an SNMP compatible console program The Switch supports SNMP version 1 0 version 2 0c and version 3 0 The SNMP agent decodes the incoming...

Страница 29: ...ey at the User name and password prompts There is no default user name and password for the Switch User names and passwords must first be created by the administrator If you have previously set up use...

Страница 30: ...rs from accessing the Switch or changing its settings This section tells how to log onto the Switch NOTE The passwords used to access the Switch are case sensitive therefore S is not the same as s Whe...

Страница 31: ...ername and Password fields You will be given access to the command prompt DES 3018 4 as shown below There is no initial username or password Leave the Username and Password fields blank Figure 4 3 Com...

Страница 32: ...t with the user name newmanager DES 3018 4 create account admin newmanager Command create account admin newmanager Enter a case sensitive new password Enter the new password again for confirmation Suc...

Страница 33: ...view read only information or receive traps using SNMP v 1 while assigning a higher level of security to another group granting read write privileges using SNMP v 3 Using SNMP v 3 individual users or...

Страница 34: ...before it can be managed with the Web based manager The Switch IP address can be automatically set using BOOTP or DHCP protocols in which case the actual address assigned to the Switch must be known T...

Страница 35: ...and the CLI or via the Web based management Connecting Devices to the Switch After you assign IP addresses to the Switch you can connect devices to the Switch To connect a device to an SFP transceive...

Страница 36: ...ess tool and can communicate directly with the Switch using the HTTP protocol The Web based management module and the Console program and Telnet are different ways to access the same internal switchin...

Страница 37: ...management features available in the web based manager are explained below Web based User Interface The user interface provides access to various Switch configuration and management screens allows yo...

Страница 38: ...a displays the Switch s ports and expansion modules showing port activity duplex mode or flow control depending on the specified mode Various areas of the graphic can be selected for performing manage...

Страница 39: ...g IGMP Snooping and Spanning Tree CoS Contains screens concerning configurations for Port Bandwidth 802 1p Default Priority 802 1p User Priority CoS Scheduling Mechanism and CoS Output Scheduling CPU...

Страница 40: ...thernet Switch Manual Section 6 Administration Device Information IP Address Port Configuration User Accounts Port Mirroring System Log Settings SNTP Settings TFTP Services Ping Test SNMP Manager Sing...

Страница 41: ...le if necessary The user may also enter a System Name System Location and System Contact to aid in defining the Switch to the user s preference In addition this screen displays the status of functions...

Страница 42: ...me The default VLAN contains all of the Switch ports as members If VLANs have been previously configured on the Switch you will need to enter the VLAN ID of the VLAN that contains the port connected t...

Страница 43: ...nfiguration file name information in the DHCP reply packet The TFTP server must be running and have the requested configuration file stored in its base directory when the request is received from the...

Страница 44: ...ical ports including port speed Clicking on Port Configurations in the Administration menu will display the following window for the user Figure 6 3 Port Configuration and The Port Information Table w...

Страница 45: ...s running a 1000BASE T cable for connection between the Switch port and other device capable of a gigabit connection The master setting 1000M Full_M will allow the port to advertise capabilities relat...

Страница 46: ...s ports click the Port Description on the Administration menu Figure 6 4 Port Description Setting and Port Description Table Use the From and To pull down menu to choose a port or range of ports to de...

Страница 47: ...n can be viewed in the preceding window Parameter Description Port Denotes the port on the Switch that has been disabled State Describes the current running state of the port in question whether enabl...

Страница 48: ...click on the Modify button for that user Figure 6 7 User Account Modify Table Add Add a new user by typing in a User Name and New Password and retype the same password in the Confirm New Password Choo...

Страница 49: ...agement Admin User Configuration Yes Read Only Network Monitoring Yes Read Only Community Strings and Trap Stations Yes Read Only Update Firmware and Configuration Files Yes No System Utilities Yes No...

Страница 50: ...configure a mirror port Select the Source Port from where you want to copy frames and the Target Port which receives the copies from the source port Select the Source Direction Ingress Egress or Both...

Страница 51: ...cription of the parameters in the following window Figure 6 11 Configure System Log Server Add The following parameters can be set Parameter Description Index Syslog server settings index 1 4 Server I...

Страница 52: ...1 local1 18 local use 2 local2 19 local use 3 local3 20 local use 4 local4 21 local use 5 local5 22 local use 6 local6 23 local use 7 local7 UDP Port 514 or 6000 65535 Enter the UDP port number used...

Страница 53: ...ttings SNTP State Use this pull down menu to Enable or Disable SNTP SNTP Primary Server The IP address of the primary server the SNTP information will be taken from SNTP Secondary Server The IP addres...

Страница 54: ...will allow its corresponding field to be configured Daylight Saving Time Offset in Minutes Use this pull down menu to specify the amount of time that will constitute your local DST offset 30 60 90 or...

Страница 55: ...l enable DST seasonal time adjustment Annual mode requires that the DST beginning and ending date be specified concisely For example specify to begin DST on April 3 and end DST on October 14 From Mont...

Страница 56: ...Settings MAC Notification is used to monitor MAC addresses learned and entered into the forwarding database To globally set MAC notification on the Switch open the following window by opening the MAC...

Страница 57: ...tory Size The maximum number of entries listed in the history log used for notification Up to 500 entries can be specified Port Settings To change MAC notification settings for a port or group of port...

Страница 58: ...elected an operation to perform enter the Server IP Address and the path of the filename in use and click Start to initiate the file transfer Figure 6 15 TFTP Services screen Ping Test Ping is a small...

Страница 59: ...on that list can do as an SNMP manager The Switch allows groups of users to be listed and configured with a shared set of privileges The SNMP version may also be set for a listed group of SNMP manager...

Страница 60: ...ay page as shown below Figure 6 18 SNMP User Table Display The following parameters are displayed Parameter Description User Name An alphanumeric string of up to 32 characters This is used to identify...

Страница 61: ...selected in the SNMP Version field and the Encryption field has been checked This field will require the user to enter a password SHA Specifies that the HMAC SHA authentication protocol will be used T...

Страница 62: ...The following parameters can set Parameter Description View Name Type an alphanumeric string of up to 32 characters This is used to identify the new SNMP view being created Subtree OID Type the Object...

Страница 63: ...le entry The following screen should appear Figure 6 22 SNMP Group Table To delete an existing SNMP Group Table entry click the corresponding under the Delete heading To display the current settings f...

Страница 64: ...supports both centralized and distributed network management strategies It includes improvements in the Structure of Management Information SMI and adds some security features SNMPv3 Specifies that th...

Страница 65: ...nk which will open the following screen Figure 6 25 SNMP Community Table window The following parameters can set Parameter Description Community Name Type an alphanumeric string of up to 32 characters...

Страница 66: ...NMP Host Table Configuration page as shown below Figure 6 27 SNMP Host Table Configuration window The following parameters can set Parameter Description Host IP Address Type the IP address of the remo...

Страница 67: ...o identify the SNMP engine on the Switch To display the Switch s SNMP Engine ID open the SNMP Manger folder located in the Administration folder and click on the SNMP Engine ID link This will open the...

Страница 68: ...um number of IP MAC Binding entries is 500 The creation of authorized users can be manually configured by CLI or Web The function is port based this means a user can enable or disable the function on...

Страница 69: ...ing checking on specific ports the ports must first be enabled in the IP MAC Binding Ports menu see above The ports are specified in the Port field as a range of integers for example 1 3 or select the...

Страница 70: ...MAC Binding Blocked in the IP MAC Binding folder to open the IP MAC Binding Blocked window Figure 6 31 IP MAC Binding Blocked window To find an unauthorized device that has been blocked by the IP MAC...

Страница 71: ...e IP subnet broadcast domain however a single switch can only belong to one group If multiple VLANs are configured the SIM group will only utilize the default VLAN on any switch SIM allows intermediat...

Страница 72: ...Figure 6 32 SIM Settings window disabled Change the SIM State to Enabled using the pull down menu and click Apply The screen will then refresh and the SIM Settings window will look like this Figure 6...

Страница 73: ...logy window will be used to configure and manage the Switch within the SIM group and requires Java script to function properly on your computer The Java Runtime Environment on your server should initi...

Страница 74: ...Name Displays the full Model Name of the corresponding Switch To view the Topology Map click the View menu in the toolbar and then Topology which will produce the following screen The Topology View w...

Страница 75: ...the mouse plays an important role in configuration and in viewing device information Setting the mouse cursor over a specific device in the topology window tool tip will display the same information...

Страница 76: ...various functions depending on the role of the Switch in the SIM group and the icon associated with it Group Icon Figure 6 38 Right Clicking a Group Icon The following options may appear for the user...

Страница 77: ...tch Icon Figure 6 40 Right Clicking a Commander Icon The following options may appear for the user to configure Collapse to collapse the group that will be represented by a single icon Expand to expan...

Страница 78: ...d to expand the SIM group in detail Remove from group remove a member from a group Configure launch the web management to configure the Switch Property to pop up a window to display the device informa...

Страница 79: ...d will display the Device Name of the switches in the SIM group configured by the user If no Device Name is configured by the name it will be given the name default and tagged with the last six digits...

Страница 80: ...nd the views to open at SIM startup Group Add to group add a candidate to a group Clicking this option will reveal the following screen for the user to enter a password for authentication from the Can...

Страница 81: ...e enter the Server IP Address where the firmware resides and enter the Path Filename of the firmware Click Download to initiate the file transfer Figure 6 49 Firmware Upgrade window Configuration File...

Страница 82: ...parameters and then click Add Modify Parameter Description VLAN ID VID The VLAN ID number of the VLAN on which the above Unicast MAC address resides MAC Address The MAC address to which packets will...

Страница 83: ...tic Multicast Forwarding Table The following parameters can be set Parameter Description VID The VLAN ID of the VLAN to which the corresponding MAC address belongs Multicast MAC Address The MAC addres...

Страница 84: ...ulticsast packets Forward unregistered groups This default setting will forward all multicast streams Filter unregistered groups This settings will forward multicasts only to registered multicast grou...

Страница 85: ...server ensuring the reliability of this function The Switch will send out e mail to recipients when one or more of the following events occur When a cold start occurs on the Switch When a port enters...

Страница 86: ...r Address Table window The following parameters can be set Parameter Description SMTP State Use the pull down menu to enable or disable the SMTP service on this device SMTP Server Address Enter the IP...

Страница 87: ...es made SMTP Service The following window is used to send test messages to all mail recipients configured on the Switch thus testing the configurations set and the reliability of the SMTP server To ac...

Страница 88: ...se nodes VLAN membership packets cannot cross VLANs without a network device performing a routing function between the VLANs The Switch supports IEEE 802 1Q VLANs The port untagging function can be us...

Страница 89: ...the following three types of rules Ingress rules rules relevant to the classification of received frames belonging to a VLAN Forwarding rules between ports decides whether to filter or forward the pac...

Страница 90: ...N information intact The VLAN information in the tag can then be used by other 802 1Q compliant devices on the network to make packet forwarding decisions Ports with untagging enabled will strip the 8...

Страница 91: ...actory default setting assigns all ports on the Switch to the default As new VLANs are configured in Port based mode their respective member ports are removed from the default Packets cannot cross VLA...

Страница 92: ...button in the 802 1Q Static VLANs menu A new menu will appear as shown below to configure the port settings and to assign a unique name and number to the new VLAN See the table below for a descriptio...

Страница 93: ...ew VLAN in the Add dialog box or for editing the VLAN name in the Modify dialog box Port Settings Allows an individual port to be specified as member of a VLAN Tag Specifies the port as either 802 1Q...

Страница 94: ...ct as a single link This gives a bandwidth that is a multiple of a single link s bandwidth Link aggregation is most commonly used to link a bandwidth intensive network device or devices such as a serv...

Страница 95: ...TP will block a single port that has a redundant link To configure port trunking click L2 Features Trunking Link Aggregation to bring up the Port Trunking Group table Figure 7 8 Port Trunking Group wi...

Страница 96: ...oping the Switch can open or close a port to a specific Multicast group member based on IGMP messages sent from the device to the IGMP host or vice versa The Switch monitors IGMP messages and disconti...

Страница 97: ...mbership report Default 260 Leave Timer This specifies the maximum amount of time in seconds between the Switch receiving a leave group message from a host and the Switch issuing a group membership qu...

Страница 98: ...port will be dynamically configured when IGMP query packets RIPv2 multicast DVMRP multicast or PIM DM multicast packets are detected flowing into a port Open the IGMP Snooping folder and the click on...

Страница 99: ...t forward packets In the STP port transition states disabled blocking or listening or in the RSTP port state discarding there is no functional difference the port is not active in the network topology...

Страница 100: ...message will be placed in the Switch s Syslog and will be defined there as BPDU Loop Back on Port Setting the LoopBack Timer The LoopBack timer plays a key role in the next step the switch will take...

Страница 101: ...ree folder in the L2 features menu and click the STP Bridge Global Settings link Figure 7 14 STP Bridge Global Settings NOTE The Hello Time cannot be longer than the Max Age Otherwise a configuration...

Страница 102: ...oot Switch A low number indicates a high priority and a high probability that this Switch will be elected as the root Switch Default Path Cost This read only field displays the protocol used in determ...

Страница 103: ...oup will use the switch level parameters entered above with the addition of Port Priority and Port Cost An STP Group spanning tree works in the same way as the switch level spanning tree but the root...

Страница 104: ...es a potential for a loop An edge port normally should not receive BPDU packets If a BPDU packet is received it automatically loses edge port status Choosing the false parameter indicates that the por...

Страница 105: ...are given values from 0 to 7 with 0 being assigned to the lowest priority data and 7 assigned to the highest The highest priority tag 7 is generally only used for data associated with video or audio...

Страница 106: ...3 has the highest priority of the four priority classes of service on the Switch In order to implement CoS the user is required to instruct the Switch to examine the header of a packet to see if it ha...

Страница 107: ...configured to empty the buffer using strict priority NOTICE The default CoS scheduling arrangement is a strict priority schedule which means the switch will consider the highest class of service to h...

Страница 108: ...arting with the selected port Type This drop down menu allows you to select between RX receive TX transmit and Both This setting will determine whether the bandwidth ceiling is applied to receiving tr...

Страница 109: ...own below Figure 8 3 802 1p Default Priority and the 802 1p Default Priority window This page allows you to assign a default 802 1p priority to any given port on the Switch The priority tags are numbe...

Страница 110: ...n the CoS folder click CoS Scheduling Mechanism to view the screen shown below Figure 8 5 CoS Scheduling Mechanism and CoS Scheduling Mechanism Table window NOTICE The default CoS scheduling arrangeme...

Страница 111: ...tomize this setting it is important to monitor network performance especially during peak demand as bottlenecks can quickly develop if the CoS settings are not suitable In the CoS folder click CoS Out...

Страница 112: ...Select the general priority setting for the ports configured Priority option include port_priority port based ethernet_priority MAC based or 802 1p Priority ip_priority TOS IP or DSCP IP none no prior...

Страница 113: ...Fast Ethernet Switch Manual Figure 8 8 TOS Priority Setting Select the TOS value from the pull down menu and the Class ID of the priority level mapped to and click the Apply button The new mapping is...

Страница 114: ...DSCP Priority Setting menu to configure DSCP priority mapping for Class of Service on the Switch Figure 8 9 DSCP Priority Setting Type the DSCP bit level and the Class ID priority from the pull down m...

Страница 115: ...riority CoS Use the From To menu to select the ports being configured the selected ports must frist be configured for port based priority in the Priority Setting menu Select the Class level for the po...

Страница 116: ...th the frame The entire process is described below CPU Interface Filtering State Settings In the following window the user may globally enable or disable the CPU Interface Filtering mechanism by using...

Страница 117: ...h to examine the IP address in each frame s header Select Packet Content Mask to specify a mask to hide the content of the packet header VLAN Selecting this option instructs the Switch to examine the...

Страница 118: ...t to instruct the Switch to examine the layer 2 part of each packet header Select IP to instruct the Switch to examine the IP address in each frame s header Select Packet Content Mask to specify a mas...

Страница 119: ...k and or a destination port mask The user may also identify which flag bits to filter Flag bits are parts of a packet that determine what to do with the packet The user may filter packets by filtering...

Страница 120: ...ts for the type of profile Select Ethernet to instruct the Switch to examine the layer 2 part of each packet header Select IP to instruct the Switch to examine the IP address in each frame s header Se...

Страница 121: ...the corresponding Modify button of the entry to configure Ethernet IP and Packet Content Each entry will open a new and unique window as shown in the examples below Figure 9 7 CPU Interface Filtering...

Страница 122: ...cts the Switch to examine the packet header VLAN Name Allows the entry of a name for a previously configured VLAN Source MAC Source MAC Address Enter a MAC Address for the source MAC address Destinati...

Страница 123: ...IP Figure 9 10 CPU Interface Filtering Rule Table IP To create a new rule set for an access profile click the Add button A new window is displayed To remove a previously created rule click the corresp...

Страница 124: ...e the layer 2 part of each packet header IP instructs the Switch to examine the IP address in each frame s header Packet Content Mask instructs the Switch to examine the packet header VLAN Name Allows...

Страница 125: ...eters Description Profile ID This is the identifier number for this profile set Mode Select Permit to specify that the packets that match the access profile are forwarded by the Switch according to an...

Страница 126: ...lue in hex form to mask the packet from byte 16 to byte 31 value 32 47 Enter a value in hex form to mask the packet from byte 32 to byte 47 value 48 63 Enter a value in hex form to mask the packet fro...

Страница 127: ...rity including Traffic Control Port Security 802 1X Trusted Host and Traffic Segmentation all discussed in detail in the following section Traffic Control Use the Traffic Control menu to enable or dis...

Страница 128: ...is cleared once every second If the broadcast multicast or unknown unicast storm control is enabled the port will discard all broadcast multicast or unknown unicast packets received when the counter e...

Страница 129: ...be set Parameter Description From To A consecutive group of ports may be configured starting with the selected port Admin State This pull down menu allows you to enable or disable Port Security locked...

Страница 130: ...lete heading of the corresponding MAC address to be deleted Click the Next button to view the next page of entries listed in this table This window displays the following information Parameter Descrip...

Страница 131: ...ol over LAN EAPOL packets between the Client and the Server The following figure represents a basic EAPOL packet Figure 10 4 The EAPOL Packet Utilizing this method unauthorized devices are restricted...

Страница 132: ...Switch whether or not the Client is granted access to the LAN and or switches services Figure 10 6 The Authentication Server Authenticator The Authenticator the Switch is an intermediary between the A...

Страница 133: ...ll endstations must be running software that is compliant with the 802 1x protocol For users running Windows XP that software is included within the operating system All other users are required to at...

Страница 134: ...owed to pass through the port The following figure displays a more detailed explanation of how the authentication process is completed between the three roles stated above Figure 10 9 The 802 1x Authe...

Страница 135: ...s the Port Based Network Access Control Port Based Network Access Control 802 1X Client 802 1X Client 802 1X Client 802 1X Client 802 1X Client 802 1X Client 802 1X Client 802 1X Client 802 1X Client...

Страница 136: ...In order to successfully make use of 802 1X in a shared media LAN segment it would be necessary to create logical Ports one for each attached device that required access to the LAN The Switch would re...

Страница 137: ...k Security 802 1X 802 1X Authenticator Settings Figure 10 12 802 1X Authenticator Settings window To configure the settings by port click on the hyperlinked port number under the Port heading which wi...

Страница 138: ...d The Switch then requests the identity of the client and begins relaying authentication messages between the client and the authentication server The default setting is Auto TxPeriod This sets the Tx...

Страница 139: ...word and confirmation of that password Properly configured local users will be displayed in the 802 1x Local User Table in the same window Port Capability Click Security 802 1X 802 1X Capability Setti...

Страница 140: ...he window below Click Security 802 1X Initialize Ports to view the following window Figure 10 16 Initialize Port window This window allows you to initialize a port or group of ports The Initialize Por...

Страница 141: ...w Click Security 802 1X 802 1X Initialize Ports to view the following window Figure 10 17 Initialize Ports MAC based 802 1x To initialize ports first choose the range of ports in the From and To field...

Страница 142: ...MAC Address Displays the physical address of the Switch where the port resides Auth PAE State The Authenticator State will display one of the following Initialize Disconnected Connecting Authenticati...

Страница 143: ...and To field Then the user must specify the MAC address to be reauthenticated by entering it into the MAC Address field and checking the corresponding check box To begin the reauthentication click App...

Страница 144: ...thentic Port Set the RADIUS authentic server s UDP port The default port is 1812 Accounting Port Set the RADIUS account server s UDP port The default port is 1813 Key Set the key the same as that of t...

Страница 145: ...lege through the web manager or Telnet session To define a management station IP setting type in the IP address and click the Apply button Traffic Segmentation Traffic segmentation is used to limit tr...

Страница 146: ...itch using the Port pull down menu Then specify the different ports that you want to be able to receive packets from the port you specified in the first part Clicking the Apply button will enter the c...

Страница 147: ...3010FL DES 3010G DES 3018 DES 3026 Fast Ethernet Switch Manual Clicking the Apply button will enter the combination of transmitting port and allowed receiving ports into the Switch s Traffic Segmentat...

Страница 148: ...zation displays the percentage of the CPU being used expressed as an integer percentage and calculated as a simple average by time interval To view the CPU Utilization window open the Monitoring folde...

Страница 149: ...centage of the total available bandwidth being used on the port To view the port utilization open the Monitoring folder and then the Port Utilization link Figure 11 2 Port Utilization window The user...

Страница 150: ...ts folder of the Monitoring menu to view the following graph of packets received on the Switch To select a port to view these statistics for use the Port pull down menu The user may also use the real...

Страница 151: ...ort Packets Counts the number of packets received on the port Unicast Counts the total number of good packets that were received by a unicast address Multicast Counts the total number of good packets...

Страница 152: ...ckets received on the Switch To select a port to view these statistics for use the Port pull down menu The user may also use the real time graphic of the Switch at the top of the web page by simply cl...

Страница 153: ...ult value is 200 Unicast Counts the total number of good packets that were received by a unicast address Multicast Counts the total number of good packets that were received by a multicast address Bro...

Страница 154: ...f packets transmitted from the Switch To select a port to view these statistics for use the Port pull down menu The user may also use the real time graphic of the Switch at the top of the web page by...

Страница 155: ...m the port Packets Counts the number of packets successfully sent on the port Unicast Counts the total number of good packets that were transmitted by a unicast address Multicast Counts the total numb...

Страница 156: ...ink in the Error folder of the Monitoring menu to view the following graph of error packets received on the Switch To select a port to view these statistics for select the port by using the Port pull...

Страница 157: ...rrence OverSize Counts packets received that were longer than 1518 octets or if a VLAN frame is 1522 octets and less than the MAX_PKT_LEN Internally MAX_PKT_LEN is equal to 1522 Fragment The number of...

Страница 158: ...the Switch To select a port to view these statistics for select the port by using the Port pull down menu The user may also use the real time graphic of the Switch at the top of the web page by simply...

Страница 159: ...Counts the number of times that a collision is detected later than 512 bit times into the transmission of a packet ExColl Excessive Collisions The number of packets for which transmission failed due...

Страница 160: ...e Two windows are offered To select a port to view these statistics for select the port by using the Port pull down menu The user may also use the real time graphic of the Switch at the top of the web...

Страница 161: ...ngth inclusive excluding framing bits but including FCS octets 512 1023 The total number of packets including bad packets received that were between 512 and 1023 octets in length inclusive excluding f...

Страница 162: ...Find Allows the user to move to a sector of the database corresponding to a user defined port VLAN or MAC address VID The VLAN ID of the VLAN of which the port is a member MAC Address The MAC address...

Страница 163: ...designated SNMP trap receiving stations and to the PC connected to the console manager Click Next to go to the next page of the Switch History Log Clicking Clear will allow the user to clear the Swit...

Страница 164: ...ode and click the Apply button to put into effect Parameter Description time_interval min 1 65535 Specifies the minimum interval between saves in minutes on_demand Specifies that logs are saved when r...

Страница 165: ...g Group Table The user may search the IGMP Snooping Group Table by VID by entering it in the top left hand corner and clicking Search The following field can be viewed Parameter Description VLAN Name...

Страница 166: ...11 19 Browse Router Port window Browse ARP Table The Browse ARP Table window may be found in the Monitoring menu This window will show current ARP entries on the Switch To clear the ARP Table click Cl...

Страница 167: ...ication window The user may also select the desired time interval to update the statistics between 1s and 60s where s stands for seconds The default value is one second To clear the current statistics...

Страница 168: ...mented due to receipt of an Access Accept Access Reject or Access Challenge a timeout or retransmission AccessResponses The number of malformed RADIUS Access Response packets received from this server...

Страница 169: ...uest as well as a timeout Requests The number of RADIUS Accounting Request packets sent This does not include retransmissions Responses The number of RADIUS packets received on the accounting port fro...

Страница 170: ...message EntersAuthenticating Counts the number of times that the state machine transitions from CONNECTING to AUTHENTICATING as a result of an EAP Response Identity message being received from the Sup...

Страница 171: ...itial Access Challenge packet from the Authentication server i e aReq becomes TRUE causing exit from the RESPONSE state Indicates that the Authentication Server has communication with the Authenticato...

Страница 172: ...e default value is one second The following fields can be viewed Parameter Description Port The identification number assigned to the Port by the System in which the Port resides Frames Rx The number...

Страница 173: ...entication Server is located within the Authenticator s System Authenticator Statistics This table contains the statistics objects for the Authenticator PAE associated with each port An entry appears...

Страница 174: ...hat have been transmitted by this Authenticator Rx RespId The number of EAP Resp Id frames that have been received by this Authenticator Rx Resp The number of valid EAP Response frames other than Resp...

Страница 175: ...hernet Switch Manual Authenticator State The following section describes the 802 1X Status on the Switch To view the Authenticator State click Monitoring Port Access Control Authenticator State Figure...

Страница 176: ...top of the window and clicking OK The information on this window is described as follows Parameter Description MAC Address Displays the Authenticator MAC address Auth PAE State The Authenticator PAE...

Страница 177: ...tion parameters to their factory defaults NOTE Only the Reset System option will enter the factory default parameters into the Switch s non volatile RAM and then restart the Switch All other options e...

Страница 178: ...ast time Save Changes was executed will be lost Click the Restart button to restart the Switch Save Changes The Switch has two levels of memory normal RAM and non volatile or NV RAM Some settings requ...

Страница 179: ...ES 3018 10 5W DES 3026 11 6W Operating Temperature 0 to 40 degrees Celsius Storage Temperature 40 to 70 degrees Celsius Humidity Operating 5 to 95 RH non condensing Storage 0 to 95 RH non condensing D...

Страница 180: ...x 10 Mbps 20Mbps 100Mbps 200Mbps n a 2000Mbps Network Cables 10BASE T 100BASE TX 2 pair UTP Cat 3 4 5 100 m EIA TIA 568 100 ohm STP 100 m 2 pair UTP Cat 5 100 m EIA TIA 568 100 ohm STP 100 m Number of...

Страница 181: ...erformance Transmission Method Store and forward RAM Buffer 32M Bytes per device Filtering Address Table 8K MAC address per device Packet Filtering Forwarding Rate 14 880 pps per 10Mbps 148 809 pps pe...

Страница 182: ...e products for matching cable pin assignment The following diagrams and tables show the standard RJ 45 receptacle connector and their pin assignments Appendix 1 1 The standard RJ 45 port and connector...

Страница 183: ...ndard Media Type Maximum Distance Mini GBIC 1000BASE LX Single mode fiber module 1000BASE SX Multi mode fiber module 1000BASE LHX Single mode fiber module 1000BASE ZX Single mode fiber module 10km 550...

Страница 184: ...n devices on the network broadcast storm Multiple simultaneous broadcasts that typically absorb available network bandwidth and can cause network failure console port The port on the Switch accepting...

Страница 185: ...lly designed to be used in managing TCP IP internets SNMP is presently implemented on a wide range of computers and networking equipment and may be used to manage many aspects of network and end stati...

Страница 186: ...defective Hardware All Hardware or part thereof that is replaced by D Link or for which the purchase price is refunded shall become the property of D Link upon replacement or refund Limited Software W...

Страница 187: ...enance Damage that occurs in shipment due to act of God failures due to power surge and cosmetic damage and Any hardware software firmware or other products or services provided by anyone other than D...

Страница 188: ...tes Copyright Act of 1976 FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to...

Страница 189: ...s attributable to the Software Except as otherwise agreed by D Link in writing the replacement Software is provided only to the original licensee and is subject to the terms and conditions of the lice...

Страница 190: ...RATED WITH ANY PRODUCT RETURNED TO D LINK FOR WARRANTY SERVICE RESULTING FROM THE USE OF THE PRODUCT RELATING TO WARRANTY SERVICE OR ARISING OUT OF ANY BREACH OF THIS LIMITED WARRANTY EVEN IF D LINK H...

Страница 191: ...istration Register your D Link product online at http support dlink com register Product registration is entirely voluntary and failure to complete or return this form will not diminish your warranty...

Страница 192: ...e including failure to operate the product in accordance with specifications or interface requirements c improper handling d failure of goods or services not obtained from D LINK or not subject to a t...

Страница 193: ...after Bedienung d Versagen von Produkten oder Diensten die nicht von D LINK stammen oder nicht Gegenstand einer zum ma geblichen Zeitpunkt g ltigen Garantie oder Wartungsvereinbarung sind e Fehlgebrau...

Страница 194: ...sation du produit non conforme ses sp cifications ou aux interfaces requises c d une mauvaise manipulation d d une panne de biens ou de services acquis aupr s d une soci t tierce non D LINK ou qui ne...

Страница 195: ...equisitos de la interfaz en el funcionamiento del producto c manejo incorrecto d errores en art culos o servicios ajenos a D LINK o no sujetos a una garant a o un contrato de mantenimiento vigentes de...

Страница 196: ...uisiti di connessione c movimentazione impropria d guasto di prodotti o servizi non forniti da D LINK o non soggetti a una garanzia successiva di D LINK o a un accordo di manutenzione e impiego o cons...

Страница 197: ...riday 8 00am to 8 00pm EST Saturday 9 00am to 1 00pm EST D Link Technical Support over the Internet http www dlink com au email support dlink com au Tech Support for customers within New Zealand D Lin...

Страница 198: ...te Tech Support for customers within South Eastern Asia and Korea D Link South Eastern Asia and Korea Technical Support over the Telephone 65 6895 5355 Monday to Friday 9 00am to 12 30pm 2 00pm 6 00pm...

Страница 199: ...stomers within India D Link Technical Support over the Telephone 91 22 26526741 91 22 26526696 ext 161 to 167 Monday to Friday 9 30AM to 7 00PM D Link Technical Support over the Internet http ww dlink...

Страница 200: ...duration of the warranty period on this product Customers can contact D Link technical support through our web site or by phone Tech Support for customers within the Russia D Link Technical Support ov...

Страница 201: ...el D Link Technical Support over the Telephone 972 971 5701 Sunday to Thursday 9 00am to 5 00pm D Link Technical Support over the Internet http www dlink co il forum e mail support dlink co il Tech Su...

Страница 202: ...mers within South Africa and Sub Sahara Region D Link South Africa and Sub Sahara Technical Support over the Telephone 27 12 665 2165 08600 DLINK For South Africa only Monday to Friday 8 30am to 9 00p...

Страница 203: ...or 800 6137 Monday to Friday 06 00am to 19 00pm Guatemala 1800 300 0017 Monday to Friday 06 00am to 19 00pm Panama 0800 560 0193 Monday to Friday 07 00am to 20 00pm Peru 0800 52049 Monday to Friday 07...

Страница 204: ...D Link D Link D Link D Link 095 744 00 99 http www dlink ru email support dlink ru 191...

Страница 205: ...ina Tel fono 0800 6661442 Lunes a Viernes 09 00 am a 22 00 pm Soporte T cnico Help Desk Chile Tel fono 800 214422 Lunes a Viernes 08 00 am a 21 00 pm Soporte T cnico Help Desk Colombia Tel fono 01800...

Страница 206: ...k Brasil www dlinkbrasil com br A D Link fornece suporte t cnico gratuito para clientes no Brasil durante o per odo de vig ncia da garantia deste produto Suporte T cnico para clientes no Brasil Telefo...

Страница 207: ...8 30 a m 7 00 p m Web http www dlinktw com tw FAQ http www dlinktw com tw support asp Email dssqa_service dlinktw com tw Phone 0800 002 615 D Link http www dlinktw com tw suppQuick asp 194...

Страница 208: ...uct U S and Canadian customers can contact D Link technical support through our website or by phone Tech Support for customers within the United States D Link Technical Support over the Telephone 888...

Страница 209: ...d D Link UK Ireland Technical Support over the Telephone 08456 12 0003 United Kingdom 44 8456 12 0003 Ireland Monday to Friday 8 00 am to 10 00 pm GMT Sat Sun 10 00 am to 7 00 pm GMT D Link UK Ireland...

Страница 210: ...sche Unterst tzung ber unsere Website per E Mail oder telefonisch anfordern Web http www dlink de E Mail support dlink de Telefon 49 1805 2787 0 12 Min aus dem Festnetz der Deutschen Telekom Telefonis...

Страница 211: ...D Link par notre site internet ou par t l phone Support technique destin aux clients tablis en France Assistance technique D Link par t l phone 0 820 0803 03 Assistance technique D Link sur internet...

Страница 212: ...e el periodo de garant a del producto Los clientes espa oles pueden ponerse en contacto con la asistencia t cnica de D Link a trav s de nuestro sitio web o por tel fono Asistencia T cnica de D Link po...

Страница 213: ...o D Link Supporto tecnico per i clienti residenti in Italia D Link Mediterraneo S r L Via N Bonnet 6 B 20154 Milano Supporto Tecnico dal luned al venerd dalle ore 9 00 alle ore 19 00 con orario contin...

Страница 214: ...ds D Link Technical Support over the Telephone 0900 501 2007 Monday to Friday 8 00 am to 10 00 pm D Link Technical Support over the Internet www dlink nl Tech Support for customers within Belgium D Li...

Страница 215: ...c techniczn klientom w Polsce w okresie gwarancyjnym produktu Klienci z Polski mog si kontaktowa z dzia em pomocy technicznej firmy D Link za po rednictwem Internetu lub telefonicznie Telefoniczna pom...

Страница 216: ...D Link poskytuje sv m z kazn k m bezplatnou technickou podporu Z kazn ci mohou kontaktovat odd len technick podpory p es webov str nky mailem nebo telefonicky Web http www dlink de E Mail support dli...

Страница 217: ...munkanapokon h tf t l cs t rt kig 9 00 16 00 r ig s p nteken 9 00 14 00 r ig k rhet a 1 461 3001 telefonsz mon vagy a support dlink hu emailc men Magyarorsz gi technikai t mogat s D Link Magyarorsz g...

Страница 218: ...rnett http www dlink no Teknisk Support Du kan finne programvare oppdateringer og bruker dokumentasjon p D Links web sider D Link tilbyr sine kunder gratis teknisk support under produktets garantitid...

Страница 219: ...knisk support til kunder i Danmark i hele produktets garantiperiode Danske kunder kan kontakte D Link s tekniske support via vores hjemmeside eller telefonisk D Link teknisk support over telefonen Tlf...

Страница 220: ...ukea asiakkailleen Tuotteen takuun voimassaoloajan Tekninen tuki palvelee seuraavasti Arkisin klo 9 21 numerosta 0800 114 677 Internetin kautta Ajurit ja lis tietoja tuotteista http www dlink fi S hk...

Страница 221: ...information D Link tillhandah ller teknisk support till kunder i Sverige under hela garantitiden f r denna produkt Teknisk Support f r kunder i Sverige D Link Teknisk Support via telefon 0770 33 00 35...

Страница 222: ...209...

Страница 223: ...h Ryde NSW 2113 Australia TEL 61 2 8899 1800 FAX 61 2 8899 1868 URL www dlink com au India D Link House Kurla Bandra Complex Road Off CST Road Santacruz East Mumbai 400098 India TEL 91 022 26526696 56...

Страница 224: ...us to support your product 1 Where and how will the product primarily be used Home Office Travel Company Business Home Business Personal Use 2 How many employees work at installation site 1 employee 2...

Страница 225: ...212...

Отзывы: