DES-3010F/DES-3010FL/DES-3010G/DES-3018/DES-3026 Fast Ethernet Switch Manual
Authenticator Diagnostics
This table contains the diagnostic information regarding the operation of the Authenticator associated with each port. An
entry appears in this table for each port that supports the Authenticator function. To view the
Authenticator Diagnostics
,
click
Monitoring > Port Access Control > Authenticator Diagnostics
.
Figure 11- 24. Authenticator Diagnostics window
The user may select the desired time interval to update the statistics, between
1s
and
60s
, where “s” stands for seconds. The
default value is one second.
The following fields can be viewed:
Parameter Description
Port
The identification number assigned to the Port by the System in which the Port
resides.
EntersConnecting
Counts the number of times that the state machine transitions to the
CONNECTING state from any other state.
EapLogOffsConnecting
Counts the number of times that the state machine transitions from
CONNECTING to DISCONNECTED as a result of receiving an EAPOL-Logoff
message.
EntersAuthenticating
Counts the number of times that the state machine transitions from
CONNECTING to AUTHENTICATING, as a result of an EAP-Response/Identity
message being received from the Supplicant.
SuccessAuthenticating
Counts the number of times that the state machine transitions from
AUTHENTICATING to AUTHENTICATED, as a result of the Backend
Authentication state machine indicating successful authentication of the
Supplicant (authSuccess = TRUE).
TimeoutsAuthenticating
Counts the number of times that the state machine transitions from
AUTHENTICATING to ABORTING, as a result of the Backend Authentication
state machine indicating authentication timeout (authTimeout = TRUE).
FailAuthenticating
Counts the number of times that the state machine transitions from
AUTHENTICATING to HELD, as a result of the Backend Authentication state
machine indicating authentication failure (authFail = TRUE).
ReauthsAuthenticating
Counts the number of times that the state machine transitions from
AUTHENTICATING to ABORTING, as a result of a reauthentication request
(reAuthenticate = TRUE).
EapStartsAuthenticating
Counts the number of times that the state machine transitions from
AUTHENTICATING to ABORTING, as a result of an EAPOL-Start message
157
Содержание DES-3010F
Страница 8: ...Warranties and Registration 173 Technical Support 184 International Offices 210...
Страница 204: ...D Link D Link D Link D Link 095 744 00 99 http www dlink ru email support dlink ru 191...
Страница 222: ...209...
Страница 225: ...212...