10BASE-T Stackable Hubs
contact information for the person responsible for administering the hub.
The
string
can be up to 64 characters long.
♦
syslocation
string
Takes
string
as the System Location, corresponding to the SNMP MIB II
variable
sysLocation.
This field is used to indicate the physical
location of the hub for administrative purposes. The
string
can be up to
64 characters long.
♦
baud-rate
n
Sets the console port transmission rate used when the port is being used
in out-of-band mode. Legal values for the parameter
n
are: 1200, 2400,
9600, and 19200.
♦
snmpt-image
string
Takes
string
(which may be up to 64 characters long) as the filename on
the TFTP server of the image file to be used. When the hub boots, it will
load the given image file from the server and execute it. This command
may be used to update the hub’s software when a new version is available
from SNMP.
♦
ip-netmask
mask
Uses
mask
as the network mask for the local network. The
mask
should
be in the form
xxx
.
xxx
.
xxx
.
xxx
, where each
xxx
is a number between 0 and
255. For a class C network with no subnetting, the netmask should be
255.255.255.0.
♦
ip-default
address
Uses
address
as the hub’s IP address. The
address
should be in the form
xxx
.
xxx
.
xxx
.
xxx
, where each
xxx
is a number between 0 and 255.
♦
auth-trap
enable/disable