CDP 1500 BSY+
Operating voltage 24 V DC!
Observe enclosed red safety slip!
Do not connect directly to the mains supply!
- Connection has to be carried out only by an
authorized electrical specialist
- Danger of violent pressure in handaccessible area
- Keep away People from the operating area of the
drive
- Keep away children from the control
- Observe pressure load diagram of the chain!
- Use only in dry rooms
- Only for inside mounting.
Use rain detector with danger of rain
(e.g. at domelights or roof windows)
- Just use unchanged original D+H parts
- Observe mounting instructions of bracket set!
A synchron-group (CDP-BSY+) can be count up to 8
drives, which communicate by a bus. Each drive has
it’s own adress. This adress is configurable with
SW-BSY+.
The last drive of a synchron-group is the master,
which controls the other drives, the slaves. Different
forces between the drives of a group will balanced
with intelligent force- and position control. In case of
malfunction respective cutoff of a drive or a position
difference > 30 mm, all drives will shut down from the
master-drive.
Visual inspection:
Wiring:
Null balance:
Call D+H Service:
Only one master-drive allowed.
The master has the last address, corresponding
to the total number of drives.
The adress is sticked on the drive.
Slaves are numbered downwards.
Example: In a group, composed of 3 drives,
there is a master 3, a slave 2 and a slave 1drive.
Attention: only applies by factory set.
As soon as the drives were reprogrammed with
SW-BSY+ the addressing might vary from
factory set addressing.
Is the group wired correctly?
Therefore look connection diagrams.
It should be null balanced. (Page 12)
Software SW-BSY+ or the special magnet
MAG 502 is required.
Drives must be configured.
Software SW-BSY+ is required.
Safety notes
Observe maximum pressure load of the chain!
Maximum pressure load of the chain is not
automatically identical with maximum pressure force
of the drive!
Pressure load diagram
250
500
750
1000
1250
1500
1750
2000
1500
1000
500
0
max.
Load
(N)
Stroke / (mm)
Intended use
- Chain drive for electric opening and closing of
heavy windows and roof area
- Operating voltage 24 V DC
-
seable for smoke ventilation, D+H Euro-SHEV
according to DIN EN 12101-2 (in check) as well as
daily natural ventilation
- Only for inside mounting
U
Performance features
Drive unit with 2,5 m silicone cable. Dependent on
the type of window, different bracket sets are
available separately.
Extent of supply
Functional description
Trouble shooting
-
icroprocessor controlled synchro electronics
BSY + for a precise synchronous run of up to
4 drives
-
ndividually programmable (via software SW BSY+)
- SHEV-high speed function (fast-running
feature in OPEN-direction)
- Clamping protection for the main closing edge
-
ocking relief after closing
- Especially quiet motor running in ventilation mode
- Symmetrical chain outlet
- Connection via pin-and-socket connector
M
I
L
- Optinal with "-AS2" = protection class 2 and
"-AS3" as well as "-LS" = protection class 3