99.825.20 2.0/07/12
12/28
English
CDP 1500 BSY+
Emergency control / Zeroing
Required distances for magnetic storage devices as well as electric and electronic devices (e. g.
pacemakers, EC cards).
Avoid injury caused by attractive forces or potential splintering of the magnet.
When the drive is by magnetic force, there are dangerous moments, which must be avoided by
advance precautions.
In particular, it must be ensured that the
to
avoid the
. There is an acute risk as
.
D+H Mechatronic AG assumes no liability for damages
attributed to improper or even negligent operation.
chain has a uniform length
risk of breaking glass
synchronous operation has been
disengaged
Attention!
1
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
3
+
-
+
=
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
-
+
+
=
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
4
Disconnect data A / B
If an overload occurs while the drive moves into the closed position, it stops and zeroes
again. A brief and quiet hum is heard.
Each drive in a set within the synchronous group must be zeroed individually (be advised
of the risk of glass breakage).
2
Reconnect data A / B
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
5
24 V DC
24 V DC
MAG 502
~280 mm
~40 mm
Klick... Klick
OPEN – emergency control
CLOSED – emergency control
CLOSED – zeroing