background image

3 of 17 

 

 

 

IMPORTANT SAFETY INSTRUCTIONS 

1.  Read these instructions. 
2.  Keep these instructions. 
3.  Heed all warnings. 
4.  Follow all instructions. 
5.  Do not use this apparatus near water. 
6.  Clean only with dry cloth. 
7.  Do not block any ventilation openings.  Install in accordance with the manufacturer's instructions. 
8.  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus 

(including amplifiers) that produce heat.  

9.  Do not defeat the safety purpose of the polarized or grounding-type plug.  A polarized plug has two 

blades with one wider than the other.  A grounding type plug has two blades and a third grounding 
prong.  The wide blade or the third prong are provided for your safety.  If the provided plug does not fit 
into your outlet, consult an electrician for replacement of the obsolete outlet.  

10.  Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, 

and the point where they exit from the apparatus. 

11.  Only use attachments/accessories specified by the manufacturer. 
12.  Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the 

apparatus.  When a cart is used, use caution when moving the cart/apparatus combination to avoid 
injury from tip-over.   

13.  Unplug this apparatus during lightning storms or when unused for long periods of time.  
14.  Refer all servicing to qualified service personnel.  Servicing is required when the apparatus has been 

damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects 
have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate 
normally, or has been dropped.  

15.  Do not expose this apparatus to dripping or splashing and ensure that no objects filled with liquids, such 

as vases, are placed on the apparatus.  

16.  To completely disconnect this apparatus from the AC Mains, disconnect the power supply cord plug 

from the AC receptacle.  

17.  The mains plug of the power supply cord shall remain readily operable.  
18.  Do not expose batteries to excessive heat such as sunshine, fire or the like. 
 

 

 

 

The lightning flash with arrowhead symbol within an equilateral 
triangle is intended to alert the user to the presence of uninsulated 
"dangerous voltage" within the product's enclosure that may be of 
sufficient magnitude to constitute a risk of electric shock to 
persons. 

 

 

 

The exclamation point within an equilateral triangle is intended to 
alert the user to the presence of important operating and 
maintenance (servicing) instructions in the literature accompanying 
the product.   

 

This symbol indicates that you must communicate with the 
manufacturer for disposal of the equipment. 

 

WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. 

Содержание 2250i

Страница 1: ...150 914 0001 EN2 2250i 2400i ACTUATORS 2 actuators 2 axis system INSTALLATION GUIDE Technical Support 1 888 442 3269 ext 264 Fax 450 442 3230 E mail techsupport d box com Visit us at www d box com...

Страница 2: ...mounting hole dimensions 9 6 Setting up the actuators in the seat 9 7 Connecting the actuators to the ACM Actuator Control Module 10 8 D BOX 2250i 2400i Electrical diagram 11 9 Pictures of D BOX 2250i...

Страница 3: ...g lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supp...

Страница 4: ...ding a steel bar that will join the two side armrest together The front reinforcement part can also be made of hard wood or steel See pictures at the end of this document for more details Each actuato...

Страница 5: ...2 Washer Lock 1 4 Black 102 0051 12 Included with the L bracket option 2 Actuators 801 0007 Washer Lock tooth 1 4 Zn 102 0053 8 Screw Bolt Hex Cap 1 4 20 X 1 Black 000 100 0555 Z00 8 Tiewrap 7 3 8 190...

Страница 6: ...as the connections to each actuator will be easier and because each actuator is supplied with a 51 cable Below you will find the dimensions of the 2250i 2400i actuators and the ACM unit D BOX 2250i 24...

Страница 7: ...o be installed into armrest of qualified home theater seating Each Actuator must be inserted into the armrest hole especially made for that purpose Please see drawing below Also refer to armrest hole...

Страница 8: ...f each armrest For that purpose an actuator mounting hole and an actuator cable access hole should be provided See drawing below for more details 4 Positioning the actuators Bottom view of seating Typ...

Страница 9: ...bly hole Before making the connections between each ACM unit and its associated pair of actuators you should insert and screw down one actuator in each armrest and run the cable through the actuator c...

Страница 10: ...ge inside the ACM unit and only service qualified technician are allowed to do the connections B In order to connect each actuator into the ACM unit you need to take the ACCESS COVER off by removing t...

Страница 11: ...ssemble and secure the access cover there is one 1 screw on each side and two 2 screws on the rear Note that the screws attaching the rear cover passes through the actuator metal door 8 D BOX 2250i 24...

Страница 12: ...cables motor cables power cables and Cat 5 cables are properly secured Also make sure that none of the cables can rub against a moving part such as the reclining mechanism because it may damage the in...

Страница 13: ...13 of 17 Pictures of D BOX 2250i 2400i installation in a loveseat NOTE Cables must be positioned so they won t interfere with the recliner s mechanism...

Страница 14: ...14 of 17 Pictures of D BOX 2250i 2400i installation in a loveseat NOTE Cables must be positioned so they won t interfere with the recliner s mechanism...

Страница 15: ...15 of 17 Pictures of D BOX 2250i 2400i installation in a single electrical reclining seat NOTE Cables must be positioned so they won t interfere with the recliner s mechanism...

Страница 16: ...16 of 17 Pictures of D BOX 2250i 2400i installation in a single electrical reclining seat...

Страница 17: ...17 of 17 Appendix 1 Installation of the ACM bracket...

Отзывы: