AES diagnostics and status information
AES Device Status
V1: E V2: E V3: A
AES Device Status
V: 96k0 V: 96k0
Also under the AES/EBU Sub Menu is the AES Status Information option, which can be used to check
the incoming sample rate(s) and confirm that the data is being received correctly.
Pressing ENTER will first show
This display shows the correct operation of the three AES transmitters V1, V2 and V3. The letter after
each is the silicon version (and is of no importance to the user).
Pressing ENTER again will show
This display shows the status of the two AES receivers, input A on the left, and Input C on the right. The
sample rate the unit has been able to lock to is shown, or UNLOCKED will be displayed in its place. The unit
will lock to sample rates from 32kHz up to and including 192kHz.
The unit's own processing sample rate is 96kHz, and AES output data is always at 96kHz. Internal
sample rate converters will translate all incoming rates to 96kHz – one converter for each AES input. This
allows the two input streams to be at different rates if necessary.
24
DSP-4080
User’s Manual
Содержание DSP-4080
Страница 2: ...DSP 4080 ...
Страница 6: ...DSP 4080 User s Manual ...
Страница 8: ...DSP 4080 User s Manual ...
Страница 46: ...DSP 4080 User s Manual ...
Страница 47: ......