ANNEX : DASnet cables

11

With each system, 

cabling and patch panels are provided

. It is very important to use the system 

with the intended cables to prevent electromagnetic interferences between the analog audio signal, 
the  DASnet  data  and  the  power.  Be  sure  to  check  the  specifications  provided  by  the  cable 
manufacturer. It is also especially important when installing connectors yourself,  to note that when 
termination is not accurate, a cable will be unable to achieve its maximum performance and could 
have interferences.

There are 4 different types of cables. 

 

- The main feeds which include power and a STP, CAT7 cable. These cables are named 

eCP_xx

 (xx refers to cable length).

 

- The links between cabinets (aero40A/Convert15A/LX-218CAnet), which are STP CAT7 

cables. Cable code 

eC_09

 

- Power Links between cabinets.Cable code 

Plink1_09

 

Links for RoadNet series. Power+STP CAT7. eCPk_1/eCPk_5

The main feed cable eCP_xx has the following structure:

AL Shield

2

2

ecP_xx:   Power cable 3x2,5mm  + CAT7 4x (2 x 0,14mm  )

Jacket

Jacket

STP CAT 7 cable with Aluminium Shield for 
each individual pair and a main aluminium 
Shield.
The main Shield has to be soldered to the 
etherCon housing.

The eC_09 cable is a CAT5e cable with 
global Aluminium Shield.

Important

The pin out of the EtherCon to XLR is the following on the eCP cables:

Orange-White  

 

Audio+ 2

Orange 

 

 

Audio- 3

Green-White   

 

Audio Earth 1

Blue      

Blue-White        

Green   

 

 

Data Earth 1

Brown-White   

 

Data- (A) 3

Brown   

 

 

Data+ (B) 2

etherCon

XLR

Manual del Usuario

 / DASnet Splitter / 

User’s Manual

Содержание 20503060

Страница 1: ... Antes de utilizar el equipo lea la sección Precauciones de seguridad de este manual Conserveestemanualparafuturasconsultas Before operating the device please read the Safety precautions section of this manual Retainthismanualforfuturereference DASnet ...

Страница 2: ...6 LX 218CA 12 AERO 40A 9 LX 218CA INTRODUCTION LINE DRAWINGS 3 4 5 10 9 11 SPECIFICATIONS ANNEX CONFIGURATIONS DASnet cables SAFETY PRECAUTIONS WARRANTY DECLARATION OF CONFORMITY Manual del Usuario DASnet Splitter User s Manual ...

Страница 3: ...permanently the electrical system of the building must incorporate a multipolar switch with a separation of contact of at least 3mm in each pole Limpie con un paño seco No use limpiadores con disolventes Clean only with a dry cloth Do not use any solvent based cleaners No existen partes ajustables por el usuario en el interior de este equipo Cualquier operación de mantenimiento o reparación debe s...

Страница 4: ...el comprador en todos los casos Para solicitar reparación en garantía es imprescindible que el producto no haya sido previamente manipulado e incluir una fotocopia de la factura de compra All our products are warrantied against any manufacturing defect for a period of 2 years from date of purchase The warranty excludes damage from incorrect use of the product All warranty repairs must be exclusive...

Страница 5: ...or professional use Part 2 Immunity l EN 50581 2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances Cumple con los objetivos esenciales de las Directivas Abide by essential objectives relating Directives l de Baja Tensión Low Voltage Directive 2014 35 UE l de Compatibilidad Electromagnética EMC 2014 30 UE l Ro...

Страница 6: ...ximum number of units will depend on the system s current consumption It includes one power input by means of one powercon true 1 connector black yellow and one analog audio plus monitoring data input by the use of an ethercon connector It includes three power outputs by means of three powercon NAC3MPB connectors white PowerCon True1 in the DASNET SPLITTER TR1 and three analog audio plus monitorin...

Страница 7: ... 4A RMS 2 x 40A 80A Peak 2 x LX 218CA NET 2 x 6 2A 12 4A RMS 2 x 40A 80A Peak 2 x LX 218CA NET 2 x 6 2A 12 4A RMS 2 x 40A 80A Peak 3 x AERO 40A 3 x 6A 18A RMS 3 x 16A 48A Peak 3 x AERO 40A 3 x 6A 18A RMS 3 x 16A 48A Peak 3 x AERO 40A 3 x 6A 18A RMS 3 x 16A 48A Peak 115V DASNET RACK maximum number of cabinets 9 AERO 40A 6 LX 218CA NET With these values in one phase we will have RMS current 3 x AERO...

Страница 8: ...0A peak 60A 3 x LX 218CA NET 3 x 3 1A 9 3A RMS 3 x 20A peak 60A 3 x LX 218CA NET 3 x 3 1A 9 3A RMS 3 x 20A peak 60A 4 x AERO 40A 4 x 3A RMS 12A 4 x 16A peak 64A 4 x AERO 40A 4 x 3A RMS 12A 4 x 16A peak 64A 4 x AERO 40A 4 x 3A RMS 12A 4 x 16A peak 64A With these values in one phase we will have RMS current 4 x AERO 40A and 3 x LX 218CA NET 12A 9 3A RMS 21 3A RMS phase max RMS current is 32A Peak cu...

Страница 9: ...15A Breakers type C 16A Breakers type D 20A Short term current peak 5In I 10In Short term current peak 10In I 20In 3A 6 2A 6A 20A 16A 40A 32A 230V 230V 115V 115V 230V 230V 115V 115V Important considerations Check the system s configurations AERO 20A AERO 40A for more information regarding the quantity of cabinets that should be connected to the DASNET SPLITTER Consider if you are using different p...

Страница 10: ... DIMENSIONS IN MILLIMETERS ALL DIMENSIONS IN MILLIMETERS OPENED CLOSED Top View Top View Front View Front View Left View Left View Rear View Rear View Manual del Usuario DASnet Splitter User s Manual 250 276 206 65 250 197 ...

Страница 11: ...to cable length The links between cabinets aero40A Convert15A LX 218CAnet which are STP CAT7 cables Cable code eC_09 Power Links between cabinets Cable code Plink1_09 Links for RoadNet series Power STP CAT7 eCPk_1 eCPk_5 The main feed cable eCP_xx has the following structure AL Shield 2 2 ecP_xx Power cable 3x2 5mm CAT7 4x 2 x 0 14mm Jacket Jacket STP CAT 7 cable with Aluminium Shield for each ind...

Страница 12: ... 888 DAS 4 USA DAS Audio Asia PTE LTD 3 Temasek Avenue Centennial Tower 34 36 Singapore 039190 Tel 65 6549 7760 DAS Audio Group S L C Islas Baleares 24 46988 Fuente del Jarro Valencia SPAIN Tel 34 96 134 0860 DAS do Brasil LTDA Rua Dos Andradas 382 SL Santa Efigênia São Paulo Brasil CEP 01208 000 Tel 551133330764 ...

Отзывы: