10
REMOVING THE LID
Step 4:
Before putting the gate back into operational mode, place the gate back in the position it was
in step 2.
Step 5:
Turn the thumbwheel anti-clockwise to re-engage the operator. Move the gate until you hear a
click.
Step 6:
The gate must always be operated at least three times after it has been placed back into op-
erational mode. This is called Calibration Mode as it recalibrates the gates end stoppers.
PLACING THE OPERATOR IN MANUAL OVERRIDE
STEP 2
Pull out the pin (the pin will move about 5 mm).
The lid can now be removed
STEP 1
Open the access door
SOLO/CONDO
OPERATORS
Step 1:
Unlock and open the access door (as in step 1 above).
Step 2:
To prevent the gate from knocking the end stoppers after reactivating the gate later, be sure to
take note of the current position of the gate before proceeding to step 3.
Step 3:
Turn the thumbwheel clockwise until the gate is free to move.
Thumbwheel