9
EN / CZone® COI
– Combination Output Interface
LED INDICATORS
3.4
Figure 3. LED Indicators
1.
Circuit Status LED’s
Colour
Description
Extinguished
Channel Off
Green Solid On
Channel On
1 Red Flash
Module Not Configured
2 Red Flash
Configuration Conflict
3 Red Flash
DIP Switch Conflict
4 Red Flash
Memory Failure
5 Red Flash
No Modules Detected
6 Red Flash
Low Run Current
7 Red Flash
Over Current
8 Red Flash
Short Circuit
9 Red Flash
Missing Commander
10 Red Flash
Over Temperature
11 Red Flash
Reverse Current
12 Red Flash
Current Calibration
2. Power LED
Colour
Description
Extinguished
Power Disconnected
Green
Power Available (>12V for 12V System, >20V for 24V System)
Red
Low Volts (<12V for 12V System, <20V for 24V System)
3. Network Status LED
Colour
Description
Extinguished
Network Power Disconnected
Green
Network Power Connected
Red Flash
Network traffic
B
IL
G
E
P
U
M
P
FWD
WATE
R
P
U
M
P
E
N
GIN
E
R
O
O
M
FA
N
N
A
V
IGA
T
IO
N
L
IGHT
S
A
N
C
H
O
R
L
IGHT
S
A
L
OO
N
L
T
S
P
ORT
S
A
L
OO
N
L
T
S
S
T
B
D
GAL
L
E
Y
L
IGHT
S
C
OC
K
P
IT
L
IGHT
S
T
E
P
L
IGHT
S
H
E
A
D
L
IGHT
C
A
B
IN
L
IGHT
S
N
IGHT
L
IGHT
S
C
A
B
IN
C
T
S
Y
L
IGHT
S
C
OC
K
P
IT
C
T
S
Y
L
IGHT
S
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Green - Power
Red Flash - Traffic
NETWORK
STATUS
Green - Available
Red - Low Volts
COI
POWER
Manual Fuse Bypass
Warning! Inserting
fuse creates ignition
hazard, ensure area is
free of explosive
gases
BYPASS
NORMAL
F
U
S
E
NMEA
IN-D
OUT-L (5-16)
IN-A (1-8)
B
IL
G
E
P
U
M
P
A
F
T
Analogue Inputs (IN-A)
1 _________________________
2 _________________________
3 _________________________
4 _________________________
5 _________________________
6 _________________________
7 _________________________
8 _________________________
Digital Switch Inputs (IN-D)
1 _____________________
2 _____________________
3 _____________________
4 _____________________
5 _____________________
6 _____________________
1
DIP
COI
2 3 4 5 6 7 8
__________________
Channel LED Status Codes
GRN solid on = Channel on
1 x RED = Module not configured
2 x RED = Configuration conflict
3 x RED = Dip switch conflict
4 x RED = Memory failure
5 x RED = No modules detected
6 x RED = Low run current
7 x RED = Over current
8 x RED = Short circuit
9 x RED = Missing commander
10 x RED = Over temperature
11 x RED = Reverse current
12 x RED = Current calibration
OUT-H (1-4)
1
2
3