EN / CZone® COI
– Combination Output Interface
20
SET DIPSWITCH
4.9
Using a small screwdriver carefully set the dipswitch on the COI. The dipswitch number must be unique for all
modules on the CZone network and must match the dipswitch setting in the configuration to function correctly.
The example in Figure 15 shows a dipswitch number of 01101100 where 0 = Off and 1 = On
Figure 15. Setting Dipswitch
INITIAL POWER UP
4.10
1. Check all plugs are securely seated and connections are tight.
2.
Ensure the COI’s top cover is clipped securely in place and gasket is seated properly around fuses.
3. Power up the NMEA2000 network.
4. Check that the NMEA2000 Network LED lights up. It may also be flashing if other devices are present and
transmitting data.
5. Tu
rn the switch/circuit breaker on supplying the COI’s main positive stud.
6. Check that the Power indicator LED is green.
7. Check the
circuit’s status LED’s for each individual circuit. Refer to LED codes to diagnose any faults which
need to be rectified.
8. Check the software version on the COI with the CZone Configuration Tool and update if necessary.
9. Write configuration file to the COI and the rest of the CZone modules on the system (Refer to the CZone
Configuration Tool Instructions for details on how to configure the COI).
10. Test all inputs and outputs for configured functionality.