background image

 

COI

 

Combination Output Interface 

USER’S AND INSTALLATION MANUAL

 

V1.2 

 

 

 

Содержание COI

Страница 1: ...COI Combination Output Interface USER S AND INSTALLATION MANUAL V1 2...

Страница 2: ...ersion control Important BEP strives to ensure all information is correct at the time of printing However the company reserves the right to change without notice any features and specifications of eit...

Страница 3: ...nstallation Precautions 6 2 6 3 OVERVIEW 7 Description 7 3 1 Features 7 3 2 COI Overview 8 3 3 Led Indicators 9 3 4 Labelling 10 3 5 USB Port 10 3 6 3 6 1 General Requirements Tips 10 3 6 2 Reading Co...

Страница 4: ...ure 6 CZone COI Masterbus System Example 12 Figure 7 Detusch HDT 48 00 Crimp Tool 13 Figure 8 Output Channel Specifications 14 Figure 9 COI Bilge Pump Wiring Example 14 Figure 10 COI Deutsch Connector...

Страница 5: ...f this manual Please keep this manual in a secure place GUARANTEE SPECIFICATIONS 1 2 BEP Marine guarantees that this unit has been built according to the legally applicable standards and specification...

Страница 6: ...locations where there is danger of gas or dust explosion or potentially flammable products 3 Use of the COI other than mentioned in point 2 is not considered to be consistent with the intended purpose...

Страница 7: ...onnectors provide plug and play installation FEATURES 3 2 High density 30 channel module minimizes installation interconnections and footprint while delivering best value per circuit Full mechanical f...

Страница 8: ...able Red Low Volts COI POWER Manual Fuse Bypass Warning Inserting fuse creates ignition hazard ensure area is free of explosive gases BYPASS NORMAL FUSE NMEA IN D OUT L 5 16 IN A 1 8 BILGE PUMP AFT An...

Страница 9: ...LIGHT CABIN LIGHTS NIGHT LIGHTS CABIN CTSY LIGHTS COCKPIT CTSY LIGHTS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Green Power Red Flash Traffic NETWORK STATUS Green Available Red Low Volts COI POWER Manua...

Страница 10: ...From Network To read the existing configuration from the network to the USB drive you must 1 Insert a USB drive with NO existing zcf or czfwp files in the root folder 2 Press the USB button for 5sec...

Страница 11: ...ext file describing the result of the last operation performed as well as these instructions 3 6 4 Updating Device Firmware To update firmware of devices on the network you must 1 Insert a USB drive w...

Страница 12: ...ATER TANK LEVEL BLACK WATER TANK LEVEL LPG LEVEL MAIN BATTERY VOLTS KEYFOB BUTTON 1 KEYFOB BUTTON 2 PATIO LIGHT FRESH WATER TANK LEVEL Terminator Mbus CZone MasterBus Bridge Interface Red Fault Orange...

Страница 13: ...ts Electrical Tools Figure 7 Deutsch HDT 48 00 Crimp Tool ENIVRONMENT 4 2 Obey the following stipulations during installation Ensure the COI is located in an easily accessible location for quick acces...

Страница 14: ...urrent it is possible to parallel output channels up to 80A for OUT H connector and 100A for OUT L connector do not parallel outputs between connectors Plug Position Max Current External Alarm Light D...

Страница 15: ...S MALE PLUG Accepts Size 16 Contacts 1 W12S DEUTSCH LOCKING WEDGE FOR DT06 12S 1 DT06 08SA DEUTSCH DT 8 POS MALE PLUG Accepts Size 16 Contacts 1 W8S DEUTSCH LOCKING WEDGE FOR DT06 8S 1 0462 203 12141...

Страница 16: ...ions 1 Remove the COI top cover and locate the 4 mounting screw locators as shown in Figure 11 2 Place the COI on a solid flat surface 3 Screw the COI to the surface with 4 x 8G or 10G 4mm or 5mm self...

Страница 17: ...IPX5 rating 4 Insert the connector into the COI and lock into place 5 Load negatives are not connected to the COI they must be connected to a common negative bus Best wiring practice is to locate the...

Страница 18: ...ect an appropriately sized and fused cable from the battery positive terminal to the COI s M8 positive stud 2 The positive cable must be of sufficient size to carry the maximum current of all loads co...

Страница 19: ...13 14 15 16 Green Power Red Flash Traffic NETWORK STATUS Green Available Red Low Volts COI POWER Manual Fuse Bypass Warning Inserting fuse creates ignition hazard ensure area is free of explosive gase...

Страница 20: ...erly around fuses 3 Power up the NMEA2000 network 4 Check that the NMEA2000 Network LED lights up It may also be flashing if other devices are present and transmitting data 5 Turn the switch circuit b...

Страница 21: ...se ATC Fuse Alarms Overcurrent Short Circuit Low Run Current Fuse Tripped Fuse In Over ride alarms Maximum Continuous Current 150A 40 C derating above 40 C NMEA 2000 Power Consumption 250mA 12V 180mA...

Страница 22: ...ce 22 DIMENSIONS 5 4 Figure 16 COI Dimensions no covers Figure 17 COI Dimensions with covers 65 2 9 16 69 2 3 4 339 13 5 16 235 9 1 4 339 13 3 8 339 13 5 16 194 7 5 8 68 2 11 16 339 13 3 8 1 2 3 4 5 6...

Страница 23: ...UE LED 80 911 0071 00 ROCKER SWITCH ON OFF ON BLUE LED 80 911 0060 00 PUSH BUTTON SWITCH ON OFF RED LED 80 911 0063 00 PUSH BUTTON SWITCH ON OFF RED LED 80 911 0062 00 PUSH BUTTON SWITCH ON OFF BLUE L...

Страница 24: ...and Declare under our sole responsibility that the products 80 911 0119 00 CZone COI C W Connectors 80 911 0120 00 CZone COI No Connectors To which this declaration related is in conformity with the f...