cytiva 29011362 Скачать руководство пользователя страница 11

Step

Action

2

Select 

Fraction collectors from the Component types list.

Result:
All available fraction collectors are shown in the 

Component selection list.

Click the checkbox to select the added fraction collector.

Note:
Instrument modules are referred to as 

Components in UNICORN.

3

Click 

OK to apply the changes.

Check/Set delay volume

When a module has been installed after the UV monitor in the flow path, the delay
volume has to be adjusted in the 

System Settings dialog in UNICORN, to make sure that

the collected fractions correspond to the fractions indicated in the chromatogram.
Delay volumes can be set for the options 

Monitor to outlet valveMonitor to frac,

Monitor to frac 2, and pH valve. Depending on the system configuration used, different
delay volume options will be available for selection in the 

System Settings dialog. The

delay volume has to be set for all displayed options.

ÄKTA avant and ÄKTA pure Instructions 29021462 AD

11

Содержание 29011362

Страница 1: ...eusedfor Timeorvolumebasedfractionation Peakfractionation Combinedtimeorvolumebasedfractionationandpeakfractionation ItispossibletoinstalluptotwoFractioncollectorF9 Rmoduleswhenusing KTApure KTAavanth...

Страница 2: ...re Itis recommendedtoplaceFractioncollectorF9 Rontheleftsideoftheinstrument FractioncollectorF9 Rcanalsobeplacedonashelflocatedbeneaththesystem KTAavant In KTAavantitisrecommendedtoplaceFractioncollec...

Страница 3: ...Note Consider the tubing going to Fraction collector F9 R if KTA avant is turned on its swivel foot KTAavantand KTApureInstructions29021462AD 3...

Страница 4: ...tioncollectorF9 R 1 3 4 5 7 6 8 2 Part Function 1 Lockknob 2 Stationarypartofdeliveryarm 3 Deliveryarm 4 Tubingconnector 5 Tubesensor 6 Collectiontubes 7 Tuberack 8 Baseunit 4 KTAavantand KTApureInstr...

Страница 5: ...onbelowtounpacktheFractioncollectorandtoremovethe transportfixations Step Action 1 Openthetransportationbox 2 Liftoffthepieceoffoamandcheckthecontentaccordingtothesupplied packagelist KTAavantand KTAp...

Страница 6: ...iftoutFractioncollectorF9 RbytheBaseunitandplaceitonthebench NOTICE NeverliftFractioncollectorF9 RbytheDeliveryarm ThismaydamagetheFractioncollector 4 Removetheplasticbag 6 KTAavantand KTApureInstruct...

Страница 7: ...terstop 6 RemovethepieceoffoamfromundertheTuberack Installation ForinformationonhowtoassembleFractioncollectorF9 R pleaserefertothe respectiveinstrumentUser manualandFraction collector F9 C and F9 R O...

Страница 8: ...uish betweenseveralunitsofthesametype Allstandardvalvesandavailableoptional modulesarepre configuredtogivethedesiredfunction However thefunctionofavalve ormodulecanbechangedbychangingtheNodeID Also in...

Страница 9: ...p Action 1 SetNodeIDto0forFractioncollectorF9 Randto1forFractioncollectorF9 R 2nd 2 ConnectFractioncollectorF9 Rand orFractioncollectorF9 R 2ndtothe instrument KTAavantand KTApureInstructions29021462A...

Страница 10: ...ructionsbelowtoupdatethesysteminUNICORN Step Action 1 OntheToolsmenuintheAdministrationmodule clickSystem PropertiesorclicktheSystemPropertiesicontoopenthedialog Result TheSystemPropertiesdialogisdisp...

Страница 11: ...ulehasbeeninstalledaftertheUVmonitorintheflowpath thedelay volumehastobeadjustedintheSystemSettingsdialoginUNICORN tomakesurethat thecollectedfractionscorrespondtothefractionsindicatedinthechromatogra...

Страница 12: ...ns 2 Selectasystem SelectControlmode ClickOK Result Theselectedinstrumentcannowbecontrolledbythesoftware 3 OntheSystemmenu clickSettingswhenthesystemisinstateReady Result TheSystemSettingsdialogisdisp...

Страница 13: ...rF9 R 2nd Step Action 1 LiftouttheTubingholder 4 fromtheDeliveryarm 1 3 4 5 6 Part Function 1 Deliveryarm 2 Tubeadjustmentcavity 3 Sensorcontrol 4 Tubingholder 5 Tubingholdernut 6 Exposedtubingend 2 L...

Страница 14: ...ctiontube Usethe sensorcontroltopositiontheTubeholder 7 Connectionto KTApure ForFractioncollectorF9 R ConnectthetubingfromtheFractioncollector to portFraconOutletvalveV9 O V9H O V9 OsorV9H Os ForFract...

Страница 15: ...ngdiameter mm KTApure25 400 0 50 KTApure150 400 0 75 KTAavant25 500 0 50 KTAavant150 500 1 00 Note Precut standard tubing for KTA pure are delivered with the fraction collector For KTA avant cut the t...

Страница 16: ...AnyuseofUNICORNissubjecttoCytivaStandardSoftwareEnd UserLicenseAgreementforLifeSciencesSoftwareProducts A copyofthisStandardSoftwareEnd UserLicenseAgreementisavailableonrequest Allgoodsandservicesares...