KT01 KeyTouch Touchscreen Keypad
24
Summary of Security Application Messages
Security Status Messages (Comfort -> KeyTouch)
Table 3: Security Status Messages
Security Status
Messages
Group
Address
(hexadecim
al)
KeyTouch
Key
Function
Status
System Armed/
Disarmed
80
Status
Disarmed=OFF, Armed = On
Exit Delay
Started
81
-
ON when exit delay started
Entry Delay
Started
82
-
ON when entry delay started
Alarm Status
83
Status
Idle, Trouble, Alert = OFF, Alarm state = ON
Tamper
84
Status
Tamper = On, No Tamper = OFF
Panic activated
85
Status
On when Panic activated
Zone Not Ready 86
Dimmer
Ready = OFF, Not ready = Zone number
Zone “unsealed” 86
Replaced by Zone Not Ready function
Zone “sealed”
87
Not implemented
Zone open
circuit
88 Not
implemented
Zone short
circuit
89 Not
implemented
Zone Isolated
8A
Not used for KeyTouch
Battery
8B
Status
Low = ON, OK = OFF
Battery
Charging
8C Not
implemented
Zone Name
8D
Not implemented
Status Report 1 8E
-
Not used for KeyTouch
Status Report 2 8F
-
Not used for KeyTouch
Password Entry 90
-
1- Valid
2 - Invalid (See Note)
3 - Disabled
4 - re-enabled, not implemented
Mains Failure
91
Status
OK = Off, Mains Fail = On
Arm Ready/Not
Ready
92
Dimmer
Ready = OFF, Not ready = Zone number
Line Cut
94
Status
OK = Off, Cut = On
Arm Fail
95
-
Arm Fail =On
Status Report 1 AC
-
Status Report 2 AD
Note: The Invalid Password Entry message is received when there is
a wrong sign-in code entered from KeyTouch, or after pressing the
F-key as Comfort expects another key after the F, or if a key is
pressed while another keypad is active.