When the correct User Name and Password has been entered, the following
screen will appear:
Figure 3.6 - IP Address Page
With the correct login, the Local IP address and Net mask are displayed, and
can be changed if required depending on the network in which the CWM is
connected.
The Secure web server port is the port on the CWM for the web server. This is
443.
The Pass-through Port (default 10001) is another port on which the UCM
(Universal Communications Module) can be accessed via TCP/IP over the
network rather than by RS232, as with a regular UCM. This can be used for
remote upload and download configuration file with the Comfigurator software
tool. Comfort I firmware Outside 4.200 and above and CWM 5.052 and above
are required to support this feature.
NOTE: Port 80 must NOT be used for pass-through port, as it may cause
the webserver to be inaccessible!
Proxy can also be set from this page if needed.
The CWM is to be connected to the LAN via the Ethernet port and will access
the Internet through a gateway (router or PC) on the network (as shown in the
previous section). Press Next to continue to the next screen.
If the CWM is to be accessed from the Local network only and not to be
connected to the Internet, skip the LAN configuration and Renew screens and
go to the FTP Server page.
Press Next button to go to the next screen when completed.
For LAN connection the screen will be as shown in the following figure;
Comfort Webserver Module CWM02
15