Unpacking:

Remove covers from units and check interior for any shipping damage.  Remove any packing material if present.
Inventory any included parts (depending on model) such as antennas, coax cables etc.

Bench Testing:

Before installing the units in the field they should be assembled and tested at a convenient “Bench top” location.  This 
will make it easier to verify /  change settings and check operation when both units are visible at the same time.  

It is also a chance to become familiar with the system if this is the first time using the Suprex system.  It is much more 
difficult to setup and test the units when they are several thousand feet apart.

Both units will need to have the antenna and a suitable power supply connected.  For testing purposes, the units can 
share the same power supply.

During initial setup it is helpful to use the Setup/Config mode.  This allows a relative indication of the radio link quality 
between the units.  

Basic Bench Test:

1. Connect any antennas if the unit was shipped without antennas installed.

2. Connect a suitable power supply to both units.  Each unit should be provided with 8 - 16 volts DC and approx 

300mA.  Both units should be separated by a minimum of 24 inches.

3. Apply power.  After about a 1 -2  second delay both units Diagnostic LED should indicate Green.

5. Touch a jumper wire from the Ground connection the the Relay 1 input on the Central unit.  Relay #1 on the Remote 

unit should activate with an audible click and the Diagnostic LEDs should flash green on both the Central and 
Remote units.

6. Units are shipped from the factory set for the Wiegand data format. If a different format is required set the DIP switch 

to the required reader and panel format.  

7. If a reader and panel is accessible, connect the reader to the Remote unit and the Central unit to the panel and 

verify that card reads are being accepted by the access control system.  If any troubleshooting is necessary, it will be 
easier to do with both units in close proximity to each other.  

8. Once these steps are completed, the units are ready for installation it their permanent locations and final 

commissioning as a system.

Cypress Suprex RF Series - Setup and Pre-installation

Содержание SPX-5601C(1)

Страница 1: ...Page 1 of 20 SPX 5600MAN SPX 5600 Series Suprex Reader Extender RF Wireless Interface Operations Manual...

Страница 2: ...nal status of the unit Auxiliary I O connections available for Door Gate Panel status signaling Multiplexing of RF bridge providing for additional door gate on a single RF link Economical expansion ca...

Страница 3: ...Dorad0 644 Strobed Rising Mag Tek Strobed Falling Edge Reserved F2F x ON 1 2 3 4 5 6 7 8 Dip switch 4 is ON Enable Pullup resistors Dip switch 4 is OFF Disable Pullup resistors DIP Switch 1 ON Service...

Страница 4: ...C R1 Com R1 N O Card Reader D0 Clock D1 Data LED DC Power Supply SPX 5600 Series Central Quick Reference Typical Suprex Central Connections Suprex Central 1 2 3 4 5 6 7 8 Wiegand Wiegand No Filter Str...

Страница 5: ...ruction ACS Typical RF installation with repeater Typical RF installation line of sight SPX 5601C 1 SPX 5651 ACS SPX 5601C 1 SPX 5601R 1 EXP 1000R 3 EXP 1000R 2 SPX 5601R 1 SPX 5601R 1 Typical RF inst...

Страница 6: ...de rating curve The Suprex units should be operated with a filtered 12 Volt nominal DC supply Any voltage between 8 and 16 volts can be utilized by following the temperature voltage derating curve Vo...

Страница 7: ...Page left intentionally blank Page 7 of 20...

Страница 8: ...unit was shipped without antennas installed 2 Connect a suitable power supply to both units Each unit should be provided with 8 16 volts DC and approx 300mA Both units should be separated by a minimum...

Страница 9: ...l is not Receiving communication from the Remote Operating modes By setting DIP switch 1 to the ON position the unit is placed in Setup Config mode When the switch position is changed cycle power to t...

Страница 10: ...ction There are two relays available for accessory outputs at the Remote end Either relay can be used to provide the Door Strike or Gate activation function This example uses Relay 1 Wiring Example Do...

Страница 11: ...re floating nothing connected the associated output will be set to a high level When the input is set to 0Volts Ground the input will activate its associated output All Accessory outputs are Open Coll...

Страница 12: ...Page 12 of 20 Cypress Suprex Series Relay Controls Suprex Central Relay 1 IN Input Signal Relay 1 N C Relay 1 Com Relay 1 N O Suprex Remote Contact Outputs...

Страница 13: ...Page 13 of 20 Cypress Suprex Series Relay Controls Suprex Central Relay 2 IN Input Signal Relay 2 N C Relay 2 Com Relay 2 N O Suprex Remote Contact Outputs...

Страница 14: ...rm relay and monitors the condition of the communication link between the Central and Remote units Relay 3 is activated when power is applied and the communication link between the Central and Remote...

Страница 15: ...Page 15 of 20 Cypress Suprex Series Relay Controls Suprex Central Relay 4 N C Relay 4 Com Relay 4 N O Suprex Remote Contact Outputs Relay 4 IN Input Signal 5Volts DC Maximum...

Страница 16: ...orientation of the antenna will determine what is referred to as the polarization of the signal Significant reduction in range can result if the units are not oriented with the same polarity See below...

Страница 17: ...uctions and is placed away from metal objects This orientation may reduce range The metal pole is placed between antenna and other unit and the antenna is close to metal Better improved range Antenna...

Страница 18: ...ock Out RLY4 N O RLY4 Com RLY4 N C RLY3 N O RLY3 Com RLY3 N C RS232 Out RS232 In Ground Aux Out Relay2 Input Relay1 Input Access Control Panel Ground 8 to 16 VDC D0 Clock Out D1 Data Out LED In 485 48...

Страница 19: ...1000 Remote Unit 8 to 16 VDC In Ground RLY2 N O RLY2 Com RLY2 N C RLY1 N O RLY1 Com RLY1 N C RS232 Out RS232 In Ground Aux In N C N C 485 485 5 VDC Out RLY4 Input 5V RLY3 Input 5V LED Output D1 Data F...

Страница 20: ...Page left intentionally blank Page 20 of 20...

Отзывы: