![Cypress SPX-5601C(1) Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/cypress/spx-5601c-1/spx-5601c-1_operation-manual_2705976003.webp)
Page 3 of 20
External connections and DIP Switch Settings
Switch
6 7 8
0
1 x
2 x
3 x x
4 x
5 x x
6 x x
7 x x x
Wiegand
Wiegand / No Filter
Strobed Rising Edge (MR-5)
Strobed Rising Edge (Dorad0 644)
Strobed Rising (Mag-Tek)
Strobed Falling Edge
Reserved
F2F
x = ON
1 2 3 4 5 6 7 8
Dip switch #4 is ON
-Disable Pullup resistors
Dip switch #4 is OFF
-Enable Pullup resistors
DIP Switch #1 ON
-Service Mode
DIP Switch #1 OFF
-Run Mode
Central Unit Settings
Switch
6 7 8
0
1 x
2 x
3 x x
4 x
5 x x
6 x x
7 x x x
Wiegand
Wiegand / No Filter
Strobed Rising Edge (MR-5)
Strobed Rising Edge (Dorad0 644)
Strobed Rising (Mag-Tek)
Strobed Falling Edge
Reserved
F2F
x = ON
1 2 3 4 5 6 7 8
Dip switch #4 is ON
-Enable Pullup resistors
Dip switch #4 is OFF
-Disable Pullup resistors
DIP Switch #1 ON
-Service Mode
DIP Switch #1 OFF
-Run Mode
Remote Unit Settings
1 - 8 to 16 VDC In
2 - Ground
Status LED
1 - exp (+)
2 - exp (-)
3 - +5 VDC out
4 - Prog Res 2
5 - Prog Res 1
6 - LED In
7 - D1/Data out
8 - D0/Clk out
1- Relay 2 N.O.
2- Relay 2 Com
3 - Relay 2 N.C.
4 - Relay 1 N.O.
5 - Relay 1 Com
6 - Relay 1 N.C.
7 - Ground
8 - Aux in
9 - Not used
10 - Not used
1 - 8 to 16 VDC In
2 - Ground
Status LED
1 - exp (+)
2 - exp (-)
3 - +5 VDC out
4 - R4
5 - R3
6 - LED out
7 - D1/Data In
8 - D0/Clk In
1- Relay 4 N.O.
2- Relay 4 Com
3 - Relay 4 N.C.
4 - Relay 3 N.O.
5 - Relay 3 Com
6 - Relay 3 N.C.
7 - Ground
8 - Aux out
9 - R2 in
10 - R1 in
SPX-5600
Remote
SPX-5600
Central
Содержание SPX-5601C(1)
Страница 7: ...Page left intentionally blank Page 7 of 20...