![Cypress SPX-5601C(1) Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/cypress/spx-5601c-1/spx-5601c-1_operation-manual_2705976004.webp)
Page 4 of 20
Typical Suprex Remote
Connections
Suprex Remote
SPX-5600 Remote
1 2 3 4 5 6 7 8
Wiegand
Wiegand / No Filter
Strobed Rising Edge (MR-5)
Strobed Rising Edge (Dorad0 644)
Strobed Rising (Mag-Tek)
Strobed Falling Edge
Reserved
F2F
x = ON
Switch
6 7 8
0
1 x
2 x
3 x x
4 x
5 x x
6 x x
7 x x x
Switch #4 ON
Enable Pullup Resistors
Switch #4 OFF
Disable Pullup
Resistors
Diagnostic LED
Door
Strike
Ground
+8 to +16 VDC
D0/Clock In
D1/Data In
LED Out
R1 N.C.
R1 Com
R1 N.O.
Card
Reader
D0/Clock
D1/Data
LED
DC
Power
Supply
(-)
(+)
SPX-5600 Series Central Quick Reference
Typical Suprex Central Connections
Suprex Central
1 2 3 4 5 6 7 8
Wiegand
Wiegand / No Filter
Strobed Rising Edge (MR-5)
Strobed Rising Edge (Dorad0 644)
Strobed Rising (Mag-Tek)
Strobed Falling Edge
Reserved
F2F
x = ON
Switch
6 7 8
0
1 x
2 x
3 x x
4 x
5 x x
6 x x
7 x x x
Switch #4 ON
Disable Pullup Resistors
Switch #4 OFF
Enable Pullup Resistors
DC
Power
Supply
(-)
(+)
Access
Control
Panel
D0/Clock
D1/Data
LED
Diagnostic LED
Ground
+8 to +16 VDC
D0/Clock Out
D1/Data Out
LED In
R1 IN
R1 Input
Controls
Strike on
Remote
Quick Reference For Typical Connections