Document Number: 002-09764 Rev. *G
Page 28 of 39
CYBLE-212019-00
CYBLE-212023-10
IDLE2TX
BLE.IDLE to BLE. TX transition time
–
120
140
s
–
IDLE2RX
BLE.IDLE to BLE. RX transition time
–
75
120
s
–
RSSI Specifications
RSSI, ACC
RSSI accuracy
–
±5
–
dB
–
RSSI, RES
RSSI resolution
–
1
–
dB
–
RSSI, PER
RSSI sample period
–
6
–
s
–
Table 50. BLE Subsystem
(continued)
Parameter
Description
Min
Typ
Max
Units
Details/Conditions