June 3, 2004
Document No. 38-12009 Rev. *E
30
CY8C22x13 Final Data Sheet
3. Electrical Specifications
3.4.8
AC I
2
C Specifications
The following table lists guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and -40
°
C
≤
T
A
≤
85
°
C, or 3.0V to 3.6V and -40
°
C
≤
T
A
≤
85
°
C, respectively. Typical parameters apply to 5V and 3.3V at 25
°
C and
are for design guidance only or unless otherwise specified.
Figure 3-8. Definition for Timing for Fast/Standard Mode on the I
2
C Bus
Table 3-25. AC Characteristics of the I
2
C SDA and SCL Pins
Symbol
Description
Standard Mode
Fast Mode
Units
Notes
Min
Max
Min
Max
F
SCLI2C
SCL Clock Frequency
0
100
0
400
kHz
T
HDSTAI2C
Hold Time (repeated) START Condition. After this
period, the first clock pulse is generated.
4.0
–
0.6
–
µ
s
T
LOWI2C
LOW Period of the SCL Clock
4.7
–
1.3
–
µ
s
T
HIGHI2C
HIGH Period of the SCL Clock
4.0
–
0.6
–
µ
s
T
SUSTAI2C
Set-up Time for a Repeated START Condition
4.7
–
0.6
–
µ
s
T
HDDATI2C
Data Hold Time
0
–
0
–
µ
s
T
SUDATI2C
Data Set-up Time
250
–
100
a
a. A Fast-Mode I2C-bus device can be used in a Standard-Mode I2C-bus system, but the requirement t
SU;DAT
≥
250 ns must then be met. This will automatically be
the case if the device does not stretch the LOW period of the SCL signal. If such device does stretch the LOW period of the SCL signal, it must output the next data
bit to the SDA line t
rmax
+ t
SU;DAT
= 1000 + 250 = 1250 ns (according to the Standard-Mode I2C-bus specification) before the SCL line is released.
–
ns
T
SUSTOI2C
Set-up Time for STOP Condition
4.0
–
0.6
–
µ
s
T
BUFI2C
Bus Free Time Between a STOP and START Condition 4.7
–
1.3
–
µ
s
T
SPI2C
Pulse Width of spikes are suppressed by the input fil-
ter.
–
–
0
50
ns
SDA
SCL
S
Sr
S
P
T
BUFI2C
T
SPI2C
T
HDSTAI2C
T
SUSTOI2C
T
SUSTAI2C
T
LOWI2C
T
HIGHI2C
T
HDDATI2C
T
HDSTAI2C
T
SUDATI2C
[+] Feedback