CY8C22x13 Final Data Sheet
3. Electrical Specifications
3.3.5
DC Analog Reference Specifications
The following tables list guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and -40
°
C
≤
T
A
≤
85
°
C, or 3.0V to 3.6V and -40
°
C
≤
T
A
≤
85
°
C, respectively. Typical parameters apply to 5V and 3.3V at 25
°
C and
are for design guidance only or unless otherwise specified.
The guaranteed specifications are measured through the Analog Continuous Time PSoC blocks. The power levels for AGND refer to
the power of the Analog Continuous Time PSoC block. The power levels for RefHi and RefLo refer to the Analog Reference Control
register. The limits stated for AGND include the offset error of the AGND buffer local to the Analog Continuous Time PSoC block.
3.3.6
DC Analog PSoC Block Specifications
The following table lists guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and -40
°
C
≤
T
A
≤
85
°
C, or 3.0V to 3.6V and -40
°
C
≤
T
A
≤
85
°
C, respectively. Typical parameters apply to 5V and 3.3V at 25
°
C and
are for design guidance only or unless otherwise specified.
Table 3-10. 5V DC Analog Reference Specifications
Symbol
Description
Min
Typ
Max
Units
–
AGND = Vdd/2
a
CT Block Power = High
a. AGND tolerance includes the offsets of the local buffer in the PSoC block. Bandgap voltage is 1.3V ± 2%.
Vdd/2 - 0.043
Vdd/2 - 0.025
Vdd/2 + 0.003
V
Table 3-11. 3.3V DC Analog Reference Specifications
Symbol
Description
Min
Typ
Max
Units
–
AGND = Vdd/2
a
CT Block Power = High
a. AGND tolerance includes the offsets of the local buffer in the PSoC block. Bandgap voltage is 1.3V ± 2%
Vdd/2 - 0.037
Vdd/2 - 0.020
Vdd/2 + 0.002
V
Table 3-12. DC Analog PSoC Block Specifications
Symbol
Description
Min
Typ
Max
Units
Notes
R
CT
Resistor Unit Value (Continuous Time)
–
12.24
–
k
Ω
C
SC
Capacitor Unit Value (Switch Cap)
–
80
–
fF
[+] Feedback