CY62128B
MoBL
®
Document #: 38-05300 Rev. *C
Page 3 of 11
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature ................................. –65
°
C to +150
°
C
Ambient Temperature with
Power Applied............................................. –55
°
C to +125
°
C
Supply Voltage on V
CC
to Relative GND
[3]
.... –0.5V to +7.0V
DC Voltage Applied to Outputs
in High-Z State
[3]
....................................–0.5V to V
CC
+ 0.5V
DC Input Voltage
[3]
.................................–0.5V to V
CC
+ 0.5V
Current into Outputs (LOW)......................................... 20 mA
Static Discharge Voltage........................................... > 2001V
(per MIL-STD-883, Method 3015)
Latch-up Current..................................................... > 200 mA
Operating Range
Range
Ambient
Temperature (T
A
)
[4]
V
CC
Commercial
0
°
C to +70
°
C 5V
±
10%
Industrial
–40
°
C to +85
°
C
5V
±
10%
Automotive
–40
°
C to +125
°
C
5V
±
10%
Electrical Characteristics
Over the Operating Range
Parameter
Description
Test Conditions
CY62128B-55
CY62128B-70
Unit
Min.
Typ.
[2]
Max.
Min.
Typ.
[2]
Max.
V
OH
Output HIGH Voltage
V
CC
= Min., I
OH
= –1.0 mA
2.4
2.4
V
V
OL
Output LOW Voltage
V
CC
= Min., I
OL
= 2.1 mA
0.4
0.4
V
V
IH
Input HIGH Voltage
2.2
V
CC
+ 0.3
2.2
V
CC
+ 0.3
V
V
IL
Input LOW Voltage
[3]
–0.3
0.8
–0.3
0.8
V
I
IX
Input Load Current
GND
≤
V
I
≤
V
CC
–1
+1
–1
+1
µ
A
Automotive
–10
+10
µ
A
I
OZ
Output Leakage
Current
GND
≤
V
I
≤
V
CC
,
Output Disabled
–1
+1
–1
+1
µ
A
Automotive
–10
+10
µ
A
I
OS
Output Short Circuit
Current
[5]
V
CC
= Max., V
OUT
= GND
–300
–300
mA
I
CC
V
CC
Operating
Supply Current
V
CC
= Max.,
I
OUT
= 0 mA,
f = f
MAX
= 1/t
RC
Industrial,
Commercial
7.5
20
6
15
mA
Automotive
6
25
mA
I
SB1
Automatic CE
Power-down Current
—TTL Inputs
Max. V
CC
,
CE
1
≥
V
IH
or CE
2
< V
IL
,
V
IN
≥
V
IH
or
V
IN
≤
V
IL
, f = f
MAX
Industrial
Commercial
0.1
2
0.1
1
mA
Automotive
0.1
2
mA
I
SB2
Automatic CE
Power-down Current
—CMOS Inputs
Max. V
CC
,
CE
1
≥
V
CC
– 0.3V,
or CE
2
≤
0.3V,
V
IN
≥
V
CC
– 0.3V,
or V
IN
≤
0.3V, f = 0
Industrial
Commercial
2.5
15
2.5
15
µ
A
Automotive
2.5
25
µ
A
Notes:
3.
V
IL
(min.) = –2.0V for pulse durations of less than 20 ns.
4.
T
A
is the “Instant On” case temperature.
5.
Not more than one output should be shorted at one time. Duration of the short circuit should not exceed 30 seconds.
[+] Feedback