CY3280-SmartSense CapSense Auto-Tuning Kit Guide, Doc. # 001-64672 Rev. *B
17
Load CapSense Example Projects
Figure 3-5. Output Window
3.1.3
Program Project
1. Open
Program Part
in PSoC Designer by selecting
Program
>
Program Part
2. In the
Program Part
window
a. Select
MiniProg1
in the
PortSelection
box
b. Set
Acquire Mode
to
Power Cycle
.
If the board is already powered from AAA batteries or
from external supply through J2, set
Acquire Mode
to
Reset
c. Set
Verification
to
ON
. This ensures that downloaded checksum matches actual checksum
d. Set
Power Settings
to
5V
e. Click program arrow to program the device
3. Wait until programming is complete
4. Disconnect MiniProg1 from kit