CY7C67300
Document #: 38-08015 Rev. *J
Page 78 of 99
PWM Cycle Count Register
[0xC0FA] [R/W]
Register Description
The PWM Cycle Count register designates the number of cycles
to run when in one shot mode. One shot mode is enabled by
setting the Mode Select bit of the PWM Control register to ‘1’.
Count
(Bits [9:0])
The Count field designates the number of cycles (plus one) to
run when in one shot mode. For example, Cycles = PWM Cycle
Count + 1, therefore for two cycles set PWM Cycle Count = 1.
Table 130. PWM Cycle Count Register
Bit #
15
14
13
12
11
10
9
8
Field
Count...
Read/Write
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Default
0
0
0
0
0
0
0
0
Bit #
7
6
5
4
3
2
1
0
Field
...Count
Read/Write
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Default
0
0
0
0
0
0
0
0
[+] Feedback