No support for test patterns with HDR content in Pattern mode.
i
EDID Analyser Limitation
-
The EDID Analyser does not support 4-block analysis.
i
EDID Settings
-
The unit has 10 built-in EDIDs and 10 custom EDID slots.
-
Within the OSD menu’s “EDID Emulator” section, the EDID from the
currently connected sink, a built-in EDID, or a custom EDID may be
selected for use as the unit’s EDID.
-
Programming a custom EDID through the RS-232 connection is
supported.
i
IR Settings
-
The IR remote uses one out of 4 available address channels for control
of the test pattern generator, allowing up to 4 to be located in the
same area while being controlled by different remotes.
-
Select “IR Controller Address” within the “Setup” section of the OSD’s
main menu.
-
Assign an address number (from 0 to 3) that matches the setting on
the remote that is to be used with the unit. The default factory setting
is 0.
-
The IR remote’s address can be set using the two DIP switches located
on the back of the remote, inside the battery cover. The default
factory setting is 0 (off, off).
ON
1 2
0
ON
1 2
1
ON
1 2
2
ON
1 2
3
i
Image File Format
-
Uploadable image file format: 640×480/1920×1080 (RGB, 24-bit,