21
the escape sequence format “\cN1N2” where N1 is the 2-digit
Condition Port number and N2 defines the preferred formatting of
the value using the common C++ “%” string formatting style (%d,
%x, etc.).
■
Special Characters:
Special control characters that can’t normally
be typed should be entered using their ASCII hex value preceded
by the “\x” escape sequence. For example, a carriage return and
linefeed would be entered as: “\x0d\x0a”. Click on “Save Change” to
save the command.
■
SYS Commands:
Any of the unit’s own Telnet commands can be
used as commands within a macro to directly control the unit’s
features such as LED brightness, Demo Mode, etc. To use these the
command interface should be set to SysCMD.
■
Relay Commands:
If a command is intended to control the unit’s
relay interface, the only valid commands are “CLOSE” and “OPEN”.
2) Command Delete:
To completely remove a command from the unit,
click on the “Remove” button next to the command.
Note: If the deleted command was used in any macros, it will be removed
from them as well.