■  Set Input Name: 

To rename the input port, type the new name 

in the space provided in the Edit window. Click the “Save” 

button to confirm the change.

 

Note: Blank spaces (“ ”) are not allowed in names.

■  HDCP: 

Provides control over the HDCP behavior of each HDMI 

input.

 - HDCP Support Off: Completely disables support for HDCP on 

that input.

 - Refer to Source: Makes the input port support the same 

HDCP version as required by the connected source. 

 - Refer to Display: Makes the input support the HDCP version of 

the currently routed display.

 

 

5)  Preset Settings:

 This matrix can store up to eight video routing 

presets. Presets can be utilized to store multiple different routing 

states in advance for rapid, hassle-free, recall.

■  Store Preset:

 Once you have the matrix set the way you like, 

you can click the “Store” icon ( ) in the upper right corner 

of the window and the Store Current I/O Position window will 

open. Hovering the mouse over each button will display the 

current routing stored within it. You may also name the preset 

Содержание CPLUS-V8H8HPA

Страница 1: ...CPLUS V8H8HPA UHD 8x8 Matrix with Audio Output Operation Manual Operation Manual...

Страница 2: ......

Страница 3: ...chnology reserves the right to make improvements to this document and or product at any time and without notice COPYRIGHT NOTICE No part of this document may be reproduced transmitted transcribed stor...

Страница 4: ...into this product through any openings or empty slots in the unit as you may damage parts inside the unit Do not attach the power supply cabling to building surfaces Use only the supplied power suppl...

Страница 5: ...ront Panel LCD Menu 8 6 7 WebGUI Control 14 6 7 1 Video Switch Tab 16 6 7 2 EDID Settings Tab 20 6 7 3 Device Settings Tab 22 6 7 4 User Config Tab 23 6 7 5 System Settings Tab 24 6 8 Telnet Control 2...

Страница 6: ...agement feature that includes the ability to select between built in EDIDs EDIDs copied from connected sink devices as well as user provided EDIDs this matrix can solve many interconnectivity problems...

Страница 7: ...mpliant HDMI inputs and outputs support UHD resolutions up to 4096 2160 60Hz 4 4 4 8 bit Supports 16 bit Deep Color up to 1080p60 Supports pass through of LPCM up to 8 channels bitstream and HD bitstr...

Страница 8: ...letters will flash in the LCD to indicate selection Next press the IN button of the input 1 8 you wish to route to the selected outputs Finally press CONFIRM to confirm your selection and execute the...

Страница 9: ...he preset recall menu in the LCD window Press the buttons followed by the ENTER button to select and activate the preferred preset 11 LOCK Button Press to lock all button functions on the front panel...

Страница 10: ...put will be the same as the HDMI output it is paired with Note Supports LPCM 2 0 audio sources only 4 IR IN Port Connect to the provided IR Extender to extend the IR control range of the unit Ensure t...

Страница 11: ...nally press ENTER to confirm your selection and execute the routing change 3a MUTE Button Press this key to mute video output Press the key of the input 1 8 you wish to route then press mute key to mu...

Страница 12: ...ble 1 2 3 Infrared Power Ground 6 5 RS 232 Pinout and Defaults Serial Port Default Settings Baud Rate 19200 Data Bits 8 Parity Bits None Stop Bits 1 Flow Control None 1 2 3 4 5 8 7 6 9 DCD RxD TxD DTR...

Страница 13: ...unit Use the PLUS MINUS and ENTER buttons to navigate the LCD menu Press the MENU button to back out from any menu item and then press it again to close the menu MAIN MENU Video Setup Drivers Setup S...

Страница 14: ...et Setup 1 8 Downscale Setup A H N OFF Y On 1 EDID Setup Provides a variety of ways to set the EDID s used by the inputs on the unit EDID Mode Selects the EDID assignment mode used by the unit Selecti...

Страница 15: ...t to toggle the setting and then press the Enter key to confirm it When this setting is turned on 4K sources will be automatically downscaled to 1080p while maintaining the original framerate DRIVERS...

Страница 16: ...nto the unit s USB service port After the update is complete the unit will automatically reboot 3 Factory Reset Selecting YES will reset the unit s settings back to their factory defaults Note The uni...

Страница 17: ...e assigned automatically by the local DHCP server When Static is selected the IP address netmask and gateway must be set manually and additional menu items become available 2 IP When DHCP is off the I...

Страница 18: ...ff the gateway address can be set here Press the Enter button to begin editing the address and use the and buttons to adjust each value Press the Enter button to store the current number segment and m...

Страница 19: ...address is 192 168 1 50 By clicking on one of the listed devices you will be presented with the network details of that particular device 1 IP Mode If you choose you can alter the static IP network se...

Страница 20: ...e The default user name and password is admin On the left side of the browser you will see the following menu tabs where all primary functions of the unit are controllable via the built in WebGUI The...

Страница 21: ...selecting the input As you select each button they will change their color to orange The new route will become active immediately after selecting the input port and the routing information displayed o...

Страница 22: ...ote Blank spaces are not allowed in names Mute Each output can be individually muted black video no audio To mute an output please click on the switch so it reads ON Pattern Timing This setting config...

Страница 23: ...e text here Click the Save button to confirm changes Note Each line of text can have up to 64 characters after 64 characters the text automatically wraps to the next line OSD Text Size Use the dropdow...

Страница 24: ...ired by the connected source Refer to Display Makes the input support the HDCP version of the currently routed display 5 Preset Settings This matrix can store up to eight video routing presets Presets...

Страница 25: ...er each button will display the routing stored within it The preset will load immediately upon clicking the button 6 7 2 EDID Settings Tab This matrix provides the option of six standard EDIDs eight s...

Страница 26: ...DID from one of the connected displays to your local PC select the appropriate sink from the dropdown list then press the Download button Depending on your browser settings you will either be asked wh...

Страница 27: ...eam Note In some rare cases it is possible for custom or external EDIDs to cause compatibility issues with certain sources If this happens it is recommended to switch to one of the 6 default EDIDs for...

Страница 28: ...temperature and the speed of both internal fans The fan mode can be switched between Always On and Auto By default the fan control is set to Always On 6 7 4 User Config Tab This tab provides User Conf...

Страница 29: ...n DHCP mode the unit will attempt to connect to a local DHCP server and obtain IP netmask and gateway addresses automatically Press Save after making any changes to the IP configuration or mode Note T...

Страница 30: ...rol Before attempting to use Telnet control please ensure that both the unit and the PC are connected to the same active networks To Access the Command Line Interface CLI Windows 7 Click Start type cm...

Страница 31: ...rk settings to the factory defaults SET FACTORY OUT ROUTE DEFAULT Reset the unit s routing to the factory defaults SET POWER N1 Turn the unit on or place it into stand by mode Available values for N1...

Страница 32: ...OM CODE N1 Set the custom code used by the IR input N1 0000 7FFF IR custom code in ASCII hex GET IR IN CUSTOM CODE Show the current custom code used by the IR input SET FAN CONTROL MODE N1 Set the fan...

Страница 33: ...SD INFO DISPLAY N2 Enable or disable the info OSD for the specified output N1 A H Output port Available values for N2 ON Enabled OFF Disabled GET OUT N1 OSD INFO DISPLAY Show the current info OSD stat...

Страница 34: ...tputs N1 1 8 Input port GET ALL OUT ROUTE Show the current routing for all outputs SET CURRENT ROUTE TO PRESET N1 Save all current routing assignments to the specified preset N1 1 8 Preset number SET...

Страница 35: ...rt SET IN N1 NAME N2 Set the name of the specified input N1 1 8 Input port N2 Input Name 32 characters max GET IN N1 NAME Show the current name of the specified input N1 1 8 Input port SET OUT N1 NAME...

Страница 36: ...e 2 Downscale 4K to 1080p GET OUT N1 4K2K DOWNSCALE MODE Show the current 4K to 1080p downscale mode state N1 A H Output port Test Pattern Commands SET PATTERN N1 MODE N2 Enable or disable the test pa...

Страница 37: ...Hz 25 4K 50Hz 27 4K 60Hz GET PATTERN N1 TIMING Show the test pattern s current resolution for the specified output N1 A H Output port GET PATTERN TIMING LIST List all available test pattern output res...

Страница 38: ...ype used by the specified output N1 A H Output port EDID Commands SET ALL IN EDID MODE N1 Select the EDID management mode to use All or Appoint for all inputs Available values for N1 ON All mode OFF A...

Страница 39: ...ble values for N1 1 Internal 1 2 Internal 2 3 Internal 3 4 Internal 4 5 Internal 5 6 Internal 6 7 User 1 8 User 2 9 User 3 10 User 4 11 User 5 12 User 6 13 User 7 14 User 8 15 Sink A 16 Sink B 17 Sink...

Страница 40: ...Internal 4 5 Internal 5 6 Internal 6 7 User 1 8 User 2 9 User 3 10 User 4 11 User 5 12 User 6 13 User 7 14 User 8 15 Sink A 16 Sink B 17 Sink C 18 Sink D 19 Sink E 20 Sink F 21 Sink G 22 Sink H GET I...

Страница 41: ...SET USER N1 EDID DATA N2 Upload a new EDID in hex format for use as the specified User EDID N1 1 8 User EDID number N2 Hex Data EDID data Note The data block is comma delimited ASCII hex pairs and can...

Страница 42: ...HDCP MODE Show the current HDCP behavior used by the specified input N1 1 8 Input port GET IN N1 HDCP STATUS Show the current HDCP status of the specified input N1 1 8 Input port Available result code...

Страница 43: ...DCP compliance level of the display device connect ed to the specified output N1 A H Output port Available result codes 0 No HDCP 1 HDCP 1 x 2 HDCP 2 2 Ethernet Commands SET IP MODE N1 Set the IP addr...

Страница 44: ...N1 X X X X X 0 255 GET GATEWAY Show the unit s current gateway address GET MAC ADDR Show the unit s MAC address SET TELNET PORT N1 Set the unit s Telnet access port N1 0 65535 Port number GET TELNET P...

Страница 45: ...I PASSWORD N1 Set the WebGUI User login password N1 Password 16 characters max GET WEBGUI PASSWORD Show the current WebGUI User login password Note Commands will not be executed unless followed by a c...

Страница 46: ...F G H 7m 3m 3m 60 PRESET ALL INFO MUTE OUT IN ENTER CANCEL MENU CR 177 1 A 2 B 3 C 4 D 8 H 5 E 6 F 7 G Blu ray Players Projector Projector Projector Projector 4K UHDTV 4K UHDTV 4K UHDTV 4K UHDTV Power...

Страница 47: ...IR Frequency 38kHz Baud Rate 19200 Power Supply 24V 3 75A DC US EU standards CE FCC UL certified ESD Protection HBM 8kV Air Discharge 4kV Contact Discharge Dimensions W H D 438mm 44mm 269mm Case Only...

Страница 48: ...50 720 576p 50 800 600p 56 60 72 75 85 848 480p 60 1024 768p 60 70 75 85 1152 864p 75 1280 720p 50 60 1280 768p 60 75 85 1280 800p 60 75 85 1280 960p 60 85 1280 1024p 60 75 85 1360 768p 60 1366 768p 6...

Страница 49: ...40 2160p 24 HDR10 3840 2160p 50 60 4 2 0 HDR10 3840 2160p 50 60 4096 2160p 24 25 30 4096 2160p 50 60 4 2 0 4096 2160p 24 HDR10 4096 2160p 50 60 4 2 0 HDR10 4096 2160p 50 60 8 3 Audio Specifications 8...

Страница 50: ...4 8 bit 4 4 4 8 bit High Speed HDMI Cable HDMI Input 15m 10m 5m 3m HDMI Output 15m 10m 5m 3m Bandwidth Category Examples 1080p FHD Video Up to 1080p 60Hz 12 bit color Data rates lower than 5 3Gbps or...

Страница 51: ...bel DHCP Dynamic Host Configuration Protocol DVI Digital Visual Interface EDID Extended Display Identification Data Gbps Gigabits per second GUI Graphical User Interface HDCP High bandwidth Digital Co...

Страница 52: ...us Noise TMDS Transition Minimized Differential Signaling UHD Ultra High Definition 10 2Gbps UHD Ultra High Definition Plus 18Gbps UHDTV Ultra High Definition Television USB Universal Serial Bus VGA V...

Страница 53: ......

Страница 54: ......

Страница 55: ......

Страница 56: ...CYPRESS TECHNOLOGY CO LTD www cypress com tw...

Отзывы: