3
• Unit has an info OSD (when unlinked) and can be controlled via
front panel buttons, WebGUI, Telnet, and the AV over IP Master
Controller
6. OPERATION CONTROLS AND FUNCTIONS
6.1 Front Panel
POWER RESET
LINK
ISP
ISP
ON OFF
LINK
MODE
CH -
CH +
3
4
5
1
2
1
POWER LED:
This LED will flash while the unit is powering on and will
illuminate solidly once it has finished booting and is ready for use.
LINK LED:
If the unit has no network connection this LED will not
illuminate. While the unit is attempting to establish a connection
with a Transmitter this LED will flash. When the unit has established a
stable connection with a Transmitter this LED will illuminate solidly.
2
RESET Pinhole:
Press this recessed button with a paperclip tip to
reboot the unit.
Note: Settings will not be reset.
ISP Pinhole:
For factory use only.
3
ISP Switch:
For factory use only. For normal operation, this switch
should be set to “OFF”.
4
LINK/CH− Button:
This button controls multiple functions:
A
Channel −:
Press this button momentarily to decrease the
streaming channel to the previous available channel on the
local network.
Note: If no other channels are detected, the channel number
will not change.
B
Video Link:
Press and hold the button for 3 seconds to enable
or disable the Video Link. When the link is disabled and the
Receiver is connected to a display it will show the system’s
current IP and firmware information.
5
MODE/CH+ Button:
This button controls multiple functions: