10
V1.47
If you set a different address, each unit will start to listen to the channel number you have set, based on
the quantity of control channels of the unit. That means changing the settings of one channel will affect
only the selected fixture.
In the case of the PR-250T zoom, which is 1/2/3 channels fixture. If you set, for example, the address in
the 1 channel mode to channel 2, the device will use the channel 2 for control.
Note: After switching on, the device will automatically detect whether DMX 512 data is received or
not. If there is data received at the DMX input, you will see the DMX indicator light in green.
Universal DMX Control
This function allows you to use a universal DMX-512 controller to control the dimmer and strobe. A DMX
controller allows you to create unique programs tailored to your individual needs.
RDM control
The PR-250T can communicate using RDM (Remote Device Management) in accordance with ESTA’s
American National Standard E1.20-2006: Entertainment Technology RDM Remote Device Management
Over DMX512 Networks.
RDM is a bi-directional communications protocol for use in DMX512 control systems, it is the open
standard for DMX512 device configuration and status monitoring.
The RDM protocol allows data packets to be inserted into a DMX512 data stream without affecting
existing non-RDM equipment. It allows a console or dedicated RDM controller to send commands to and
receive messages from specific fixtures.
With RDM function, you can set the DMX address of your fixtures remotely. This is especially useful
when the device is installed in a remote area.
Each PR-250T has a factory set RDM UID (unique identification number).
Note: Before operation, enable RDM function in Advanced settings.