background image

12

V1.0

rotary control of dimmer, up/down/enter function function.

Dimmer & strobe function:

 

1.  Press the 

MENU

 button to enter the main menu.

2.  Press the 

UP 

or

 DOWN

 button to select 

Mode

 menu and press 

ENTER

.

3.  Press 

DOWN

 menu and select 

Manual

 sub menu.

4.  Press 

ENTER

 and select 

Brightness 

or

 Strobe

 in third menu.

5. 

Rotate the rotary knob to control the dimmer(right stop = maximum output, left stop = zero output), or 
strobe(right stop = maximum strobe, left stop = no strobe).

Note:

 Rotary dimmer or strobe function works in 

information Menu

 and 

Mode-Manual

 menu.

Zoom function:

 

1.  Press the 

MENU

 button to enter the main menu.

2.  Press the 

UP 

or

 DOWN

 button to select 

Mode

 menu and press 

ENTER

.

3.  Press 

DOWN

 menu and select 

Manual

 sub menu.

4.  Press 

ENTER

 and select 

Zoom

 in third menu.

5. 

Rotate the rotary knob to control the dimmer(right stop = minimum zoom scale, left stop = maximum 
zoom scale)

Note:

 Zoom function works in 

information Menu

 and 

Mode-Manual

 menu.

Quick switch between brightness and zoom in Main menu(

information Menu

):

 

In 

information menu(main menu) interface, you can easily switch between brightness adjustment func

-

tion and zoom function.

1. 

Make sure the display in main menu, picture below.

2.  Press the 

ENTER

 button or the Rotary knob(which also perform Enter function) to switch between 

the two functions.

Up, Down, Enter function: 

The knob can also act as up, down and enter function.
1.  Press the 

MENU

 button to enter the main menu interface.

2.  Right rotation = 

Down

, left rotation = 

Up

, press = 

Enter

 function.

Содержание FR-300C

Страница 1: ...USER MANUAL FR 300C 300 watts Cool White LED Fresnel...

Страница 2: ...ble 6 DMX 512 connection connection between fixtures 6 Art Net Connection 7 Power connection 7 Operation 8 Control Menu Map 8 Control menu 9 Main Menu 9 Addressing 9 Universal DMX Control 10 RDM contr...

Страница 3: ...the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operati...

Страница 4: ...door and color frame holder Handle Net out LCD display Menu button Up button Down button Enter button Net in Fuse Power in On off switch Safety cable anchor point Dmx out Dmx in Dmx signal indicator...

Страница 5: ...l over If you install the fixture in a location where it may cause injury or damage if it falls secure it as directed be low with a securely anchored safety cable that will hold the fixture if the pri...

Страница 6: ...DMX chain If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first fixture in the DMX chain with the...

Страница 7: ...equirements The FR 300C LED zoom luminaire operates on 100 to 240 volts AC 10 auto ranging The lumi naire contains an auto ranging power supply Power linking between fixtures The fixture with powercon...

Страница 8: ...e ArtNet Net 000 127 Set Art Net net SubNet 000 015 Set Art Net subnet in Art Net net Universe 000 015 Set Art Net universe in Art Net subnet Channel 1 2 3 4CH Art Net channel mode Auto Program 001 00...

Страница 9: ...Control menu The information menu will appear after the fixture is switched on In this menu the following status is dis played Main Menu Press the MENU button to enter the Main Menu interface Address...

Страница 10: ...e If you set for example the ad dress in the 1 channel mode to channel 2 the device will use the channel 2 for control Note After switching on the device will automatically detect whether DMX 512 data...

Страница 11: ...pose is to allow transfer of large amounts of DMX 512 data over a wide area using standard network technology Art Net designed by and copyright Artistic Licence Holdings Ltd For more detail explainati...

Страница 12: ...ect Mode menu and press ENTER 3 Press DOWN menu and select Manual sub menu 4 Press ENTER and select Zoom in third menu 5 Rotate the rotary knob to control the dimmer right stop minimum zoom scale left...

Страница 13: ...or DOWN button to select Dimmer menu and press ENTER 3 Press DOWN menu and select Mode sub menu 4 Select disired dimmer mode Custom dimmer curves 1 Press the MENU button to enter the main menu 2 Press...

Страница 14: ...55 Zoom from wide to narrow Fixture Cleaning Due to fog residue smoke and dust cleaning the internal and external optical lenses and mirror should be carried out periodically to optimize light output...

Страница 15: ...der next to the MAINS OUT socket on the connections panel To replace a fuse 1 Disconnect the fixture from power and allow it to cool for at least 10 minutes 2 Unscrew the cap of the fuseholder and rem...

Страница 16: ...8 500 Lux 5m 15 Control protocols RDM Artnet DMX control Control channels 1 2 3 4 CHs 5 Dimmer curves Flicker free with selectable PWM Color Cool white Input voltage AC100 240V 50 60Hz AC connection P...