11
V1.0
receive messages from specific fixtures.
With RDM function, you can set the DMX address of your fixtures remotely. This is especially useful
when the device is installed in a remote area.
Each FR-300C LED has a factory set RDM UID (unique identification number).
Note: Before operation, enable RDM function in Advanced settings.
Art-Net protocol
The fixtures on a data link are connected to the Ethernet with Art-Net™ communication protocol. The
control software running on your PC (or light console) has to support Art-Net protocol.
Art-Net™ communication protocol is a 10 Base T Ethernet protocol based on the TCP/IP. Its purpose is
to allow transfer of large amounts of DMX 512 data over a wide area using standard network technology.
Art-Net™ designed by and copyright Artistic Licence Holdings Ltd.
For more detail explaination of Art-Net protocol, please referring to: https://artisticlicence.com/art-net-4/
IP Address
The Art-Net protocol can operate on either a DHCP managed address scheme or using static addresses.
Net
A group of 16 consecutive Sub-Nets or 256 consecutive Universes is referred to as a net. There are 128
Nets in total.
SubNet
A group of 16 consecutive universes is referred to as a subnet. (Not to be confused with the subnet
mask).
Universe
A single DMX512 frame of 512 channels is referred to as a Universe.
Rotary Knob function
The knob in the rear panel of the FR-300C LED act as multi function. Including rotary control of dimmer,