20
- XM095-V1.1-NR
0-19
colour & gobo change normal
20-29
colour change to any position
30-39
colour & gobo change to any position
40-59
Lamp on
60-79
Lamp switch off
80-84
All motor reset
85-87
Scan motor reset
88-90
Colors motor reset
91-93
Gobo motor reset
94-96
Shutter & Dimmer motor reset
97-99
Other motor reset
100-119
Internal program 1 (secne1~8 of EEPROM)
120-139
Internal program 2 (secne9~16 of EEPROM)
140-159
Internal program 3 (secne17~24 of EEPROM)
160-179
Internal program 4 (secne25~32 of EEPROM)
180-199
Internal program 5 (secne33~40 of EEPROM)
200-219
Internal program 6 (secne41~48 of EEPROM)
220-239
Internal program 7 (secne49~56 of EEPROM)
240-255
Music Control (secne of Program 1)
Channel 17 – Pan fine 16bit
Channel 18– Tilt fine 16bit
ERROR MESSAGE
When you turn on the fixture, it will make a reset first. The display may show “XXer” while there are problems
with one or more channels. “XX” stands for channel 1, 2, 3, 4, 5, 6, 8, 9, 10, 13, 15who has the testing sensor for
positioning.
For example, when the display shows “Cyan color Er”, it means there is some error in channel 1. If there are some
errors on channel 1, channel 5, channel 6 at the same time, you may see the error message “Color Er”, “PAN
movement 8bit Er ”, “TILT movement 8bit Er” flash repeated for 5 times, and then the fixture will generate a reset
signal, all the stepper reset. If the fixture remain error message after performing reset more than 3 times, it will
detect whether the fixture has more than 3 errors. If the fixture has more than 3 errors (including 3 errors), all the
channels can not work properly; but if the fixture has less than 3 errors, only the channels which have errors can not
work properly, others can work as usual.
PAN- movement Er
(PAN-yoke movement error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing
circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the
main PCB). The PAN-
movement is not located in the default position after the reset.
TILT- movement Er
(TILT-head movement error) This message will appear after the reset of the fixture if the head’s magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the
main PCB). The TILT-
movement is not located in the default position after the reset.